HP zx6000 Installation Guide Page 18

  • Download
  • Add to my manuals
  • Print
  • Page
    / 68
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 17
Setting Up and Using Your System
System Description
Chapter 118
HP zx6000/rx2600 Physical Characteristics
NOTE Operating temperature and humidity ranges may vary depending on the
mass storage devices installed. High humidity levels can cause improper
operation of disk drives. Low humidity can aggravate static electricity
problems and cause excessive wear of the disk surface.
Characteristic Specification
Weight (standard configuration as shipped,
excluding keyboard and display):
Minimum Tower Configuration
Maximum Tower Configuration
Minimum Rack Configuration
Maximum Rack Configuration
49.4 lbs. (22.4 Kg.)
56.3 lbs. (25.5 Kg.)
38.6 lbs. (17.5 Kg.)
49.0 lbs. (22.2 Kg.)
Dimensions (same configuration as above):
Tower
Rack mount
19.5”H x 11.6”W x 26.5”D
3.4”H x 19.0”W x 26.8”D
Footprint (Tower)
0.2 m
2
(2.1 sq ft).
Power Supply
Input voltage (input current, max.)
Input frequency:
Available power (output):
Measured input power
1
:
100 - 127 VAC, 7.2 A Autoranging
200 - 250 VAC, 3.6 A Autoranging
50/60Hz
600 W
560 W
Operating Humidity 15% to 80% (relative)
Operating Temperature
Storage Temperature
Over-temperature Shutdown
+5 °C to +35 °C (+41°F to +95°F)
-40°C to +70°C (-40°F to +158°F)
+50° C (+122° F)
Altitude:
Operating:
Non-operating
10,000 ft. (3048m) max.
15,000 ft. (4600m) max.
1. In this document, available power and measured input power are
different. Measured input power is the most the system will draw for
the supported configuration. Available power is the maximum power
that the power supply is capable of delivering. As a guideline, cooling
and power specifications should be designed around the measured
input value.