HP Proliant ML350 Generation 3 Installation Guide Page 180

  • Download
  • Add to my manuals
  • Print
  • Page
    / 197
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 179
LED Indicators, Switches, and Jumpers
HP ProLiant ML350 Generation 3 Server Setup and Installation Guide E-13
HP CONFIDENTIAL
Writer: Richard O. Heath File Name: k-appe LED Indicators, Switches, and Jumpers.doc
Codename: Steel Venom Part Number: 316354-001 Last Saved On: 12/9/02 8:37 AM
Redundant ROM Settings
IMPORTANT: Switching ROM images can also be done through RBSU. Use the following
procedures when RBSU is inaccessible. For information on accessing redundant ROM options
through RBSU, refer to Chapter 5, “Server Configuration and Utilities.”
To switch from the current ROM to the backup ROM, perform the following steps:
1. Power down the server.
2. Set the system configuration switch positions 1, 5, and 6 to the on position.
3. Power up the server. The ROM will beep and halt when the ROM images have
been swapped.
4. Power down the server and reset all system configuration switch positions to the
default off position.
5. Power up the server.
SCSI Device Jumper Settings
No two SCSI devices connected to the same SCSI controller can have the same
SCSI ID. If another SCSI device is connected to the same controller, check the
SCSI ID on the device before beginning the installation procedure for the additional
device. The SCSI ID is set by jumpers located on each device. For more information.
refer to your SCSI device option documentation.
Page view 179
1 2 ... 175 176 177 178 179 180 181 182 183 184 185 ... 196 197

Comments to this Manuals

No comments