Cabling Guidelines
Storage Device Installation Guidelines
Consider the following guidelines when adding SCSI devices:
As a general rule, a maximum of seven devices may be added per channel. The
server is equipped with two integrated Ultra3 SCSI channels.
·
·
·
·
The configuration settings on each SCSI device should be set to the SCSI ID of
the bay (Bay 0 = SCSI ID 0) that it will occupy.
If only one SCSI hard drive is used, it should be installed in the lowest-numbered
bay (0).
Be sure to remove all terminating jumpers from third-party SCSI devices.
CAUTION: To prevent damage to the equipment, be sure that the server is powered
down, all cables are disconnected from the back of the server, and the power cord is
disconnected from the grounded (earthed) AC outlet before installing devices.
CAUTION: Electrostatic discharge (ESD) can damage electronic components. Be
sure that you are properly grounded (earthed) before beginning any installation
procedure. Refer to Appendix B, “Electrostatic Discharge,” for more information.
4-2 HP ProLiant ML350 Generation 3 Server Setup and Installation Guide
HP CONFIDENTIAL
Writer: Richard O. Heath File Name: e-ch4 Cabling Guidelines.doc
Codename: Steel Venom Part Number: 316354-001 Last Saved On: 12/9/02 8:20 AM