Table 11 Get self test results command response data
Data fieldResponse data byte
number
Completion code.1
2
55h — No error. All self tests passed.
56h — Self test function not implemented in this controller.
57h — Corrupted or inaccessible data or devices.
58h — Fatal hardware error (system should consider MC inoperative). This indicates that
the controller hardware (including associated devices such as sensor hardware or RAM)
may need to be repaired or replaced.
FFh — Reserved.
All other — Device-specific internal failure. Refer to the particular device specification for
definition.
For byte 2 =:3
55h, 56h, FFh: 00h
58h, all other: Device-specific.
57h: self-test error bitfield. A return of 57h does not imply that all tests were run, just that
a given test has failed. For example, 1b means failed, 0b means unknown.
[7] — 1b = Cannot access SEL device.
[6] — 1b = Cannot access SDR repository.
[5] — 1b = Cannot access MC FRU device.
[4] — 1b = IPMB signal lines do not respond.
[3] — 1b = SDR repository empty.
[2] — 1b = Internal use area of MC FRU corrupted.
[1] — 1b = Controller update boot block firmware corrupted.
[0] — 1b = Controller operational firmware corrupted.
Get ACPI power state command
This command is available to the MC.
The command is used to retrieve the present power state information that has been set into the
controller. This is an independent setting from the system power state that may not necessarily
match the actual power state of the system. Unspecified bits and codes are reserved and returned
as 0.
Table 12 Get ACPI power state command response data
Data fieldResponse data
byte number
Completion code1
ACPI system power state2
[7] — Reserved
[6:0] — System power state enumeration
WorkingS0 / G000h
Hardware context maintained, typically equates to
processor/chip set clocks stopped
S101h
Typically equates to stopped clocks with processor/cache
context lost
S202h
34 Command specification