Table 101 Get sensor reading command request data (continued)
[3] = 1b = state 3 asserted
[2] = 1b = state 2 asserted
[1] = 1b = state 1 asserted
[0] = 1b = state 0 asserted
For discrete reading sensors only. (Optional)(5)
(00h Otherwise)
[7] = Reserved. Returned as 1b. Ignore on read.
[6] = 1b = state 14 asserted
[5] = 1b = state 13 asserted
[4] = 1b = state 12 asserted
[3] = 1b = state 11 asserted
[2] = 1b = state 10 asserted
[1] = 1b = state 9 asserted
[0] = 1b = state 8 asserted
DCMI specific commands
This section includes commands specific to the Data Center Manageability Interface implementation
in Moonshot. Table 102 (page 130) shows the completion codes and definitions found in data byte
1 of DCMI specific command responses.
Table 102 DCMI completion codes
DefinitionCode
Command completed normally.00h
Node busy. Command could not be processed because command processing resources are temporarily
unavailable.
C0h
Invalid Command. Used to indicate an unrecognized or unsupported command.C1h
Command invalid for given LUN.C2h
Timeout while processing command. Response unavailable.C3h
Out of space. Command could not be completed because of a lack of storage space required to
execute the given command operation.
C4h
Reservation cancelled or invalid reservation ID.C5h
Request data truncated.C6h
Request data length invalid.C7h
Request data field length limit exceeded.C8h
Parameter out of range. One or more parameters in the data field of the request are out of range.
This is different from ‘Invalid data field’ (CCh) code in that it indicates that the erroneous fields have
a contiguous range of possible values.
C9h
Cannot return number of requested data bytes.CAh
Requested sensor, data, or record not present.CBh
Invalid data field in request.CCh
Command illegal for specified sensor or record type.CDh
Command response could not be provided.CEh