HP Moonshot 1500 Chassis User Manual Page 15

  • Download
  • Add to my manuals
  • Print
  • Page
    / 189
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 14
Table 5 Moonshot virtual management controller functions (continued)
Applicable Virtual Management ControllerDescriptionFunction
NodeCartPower
Supply
ChassisZone
The SDR Repository must be accessible via the
system interface. If an IPMB is provided, the SDR
Repository must be readable via that interface as
well. SDR update via the IPMB interface is optional.
SDR Repository access when the system is powered
up or in ACPI ‘S1’ sleep is mandatory, but access
when the system is powered -down or in a >S1
sleep state is optional.
xxxxxThe IPMB is highly recommended, but optional. The
MC must provide the system interface to the IPMB.
IPMB Interface
If an IPMB is imp lemented, at least one of the
specified IPMB connectors must be provided. Refer
to the IPMB Protocol specification for connector
definition. In addition the MC must implement a
message channel that allows messages to be sent
from the IPMB to the system interface, and
vice-versa, and any other mandatory IPMB support
functions and commands.
xThe MC must provide the standardized Watchdog
Timer interface, with support for system reset action.
Watchdog
Timer
Certain functions within the Watchdog Timer are
optional. Refer to the sections on the Watchdog
Timer for information.
xxThe MC must implement an Event Receiver function
and accept Event Messages via the system interface.
Event Receiver
If an IPMB is provided, the Event Receiver function
must also accept Event Messages from the IPMB.
Event Receiver operation while the system is
powered up or in ACPI ‘S1’ sleep is mandatory,
but operation when the system is powered down or
in a >S1 sleep state is optional.
xxThe MC must provide a System Event Log interface.
The event log must hold at least 16 entries. SEL
SEL Interface
access must be provided via the system interface.
The SEL must be fully accessible via all mandatory
SEL commands through all supported interfaces to
the MC whenever the system is powered up or in
ACPI 'S1' sleep state. SEL read access is always
mandatory whenever the MC is accessible, and
through any interface that is operational, regardless
of system power state.
xxxxxThe MC must provide a logical Primary FRU
inventory device , accessible via the Write- and
FRU Inventory
Read FRU Data commands. The FRU
Inventory Device Info command must also
be supported. It is highly recommended that all other
management controllers also provide a Primary FRU
inventory device. (This was optional in IPMI v1.0.)
xxxxxThe initialization agent function is one where the
MC initializes event generation and sensors both
Initialization
Agent
internally and on other management controllers
according to initialization settings stored in the SDR
for the sensor.
15
Page view 14
1 2 ... 10 11 12 13 14 15 16 17 18 19 20 ... 188 189