HP R2200 User Manual Page 8

  • Download
  • Add to my manuals
  • Print
  • Page
    / 61
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 7
Component identification 8
Item Description Function
6 Battery Warning LED
Red—During a self-test, the UPS found that the batteries must be
recharged. Charge the batteries and repeat the self-test ("Initiating a self-
test" on page 35).
7 Mute/Test button
Silences UPS alarms and initiates a self-test ("Initiating a self-test" on
page 35).
1
IMPORTANT: While in Standby mode, the UPS maintains the charge on the batteries, but no power is
available at the output receptacles. The UPS remains in Standby mode until an alternate mode is selected or
until utility power is removed.
UPS R/T2200 NA/JPN/TWN rear panel
Item Description
1
Load segment 1 (one NEMA 5-15 output receptacle for
surge and battery backup protection)
2
Load segment 2 (one NEMA 5-15 output receptacle for
surge and battery backup protection)
3
Load segment 3 (one NEMA 5-20 output receptacle for
surge and battery backup protection)
4
Load segment 4 (five unswitchable NEMA 5-15/20 output
receptacles for surge and battery backup protection)
5 Input circuit breaker
6 Input power cord with NEMA 5-20 plug
7 Serial communications port
8 USB communications port
9 REPO port
10 Voltage configuration and charge rate DIP switches
11 Power sensitivity adjustment dial
12 Ground bonding screw
Page view 7
1 2 3 4 5 6 7 8 9 10 11 12 13 ... 60 61

Comments to this Manuals

No comments