LossSig. Loss of signal (electrical or optical) to the receiver port of a Fibre Channel node.
PrimSeq. Primitive Sequence Protocol Error. There were errors during the transmission of a
Fibre Channel primitive sequence. This might indicate an error during the loop recovery or
initialization.
InvWord. Invalid Transmission Word. Illegal Fibre Channel transmission word received.
InvCRC. Invalid Cyclical Redundancy Check. Data corruption in the Fibre Channel frame.
NOTES
If the both subcommand is specified, the resulting output text is greater than 80 columns
wide.
Internal HP 3PAR counters are checked every 10 minutes.
Each LESB counter is a 32-bit, unsigned integer.
LESB counters on Fibre Channel devices cannot be reset.