setcage
DESCRIPTION
The setcage command enables service personnel to set or modify parameters for a drive cage.
SYNTAX
setcage [subcommand <arg>]... <cage_name>
AUTHORITY
Super, Service
Any role granted the cage_set right.
NOTE: You need access to all domains in order to run this command.
SUBCOMMANDS
position <position>
Sets a description for the position of the cage in the cabinet, where <position> is a description
to be assigned by service personnel (for example, left-top)
ps <model>
Sets the model of a cage power supply, where <model> is a model name to be assigned to the
power supply by service personnel. This model name appears in the Model column of the showcage
-d command output.
OPTIONS
None.
SPECIFIERS
<cage_name>
Indicates the name of the drive cage that is the object of the setcage operation.
RESTRICTIONS
Access to all domains is required to run this command.
EXAMPLES
The following example demonstrates how to assign cage1 a position description of Side Left:
cli% setcage position Cabinet 0 Bay 5 Side Left cage1
The following example demonstrates how to assign model names to the power supplies in cage1.
In this example, cage1 has two power supplies (0 and 1). Both power supplies are assigned model
name Magnetek.
cli% setcage ps 0 Magnetek ps 1 Magnetek cage1