RESTRICTIONS
Access to all domains is required to run this command.
EXAMPLES
The following example displays a cage with firmware level of 4.41 upgrading to 4.42:
cli% upgradecage a
Upgrading cage cage0 cpuA from rev 1.46 to revision in file
/opt/tpd/fw/cage/dc2/lbod_fw.bin-2.05.
Upgrading cage cage1 cpuA from rev 1.46 to revision in file
/opt/tpd/fw/cage/dc2/lbod_fw.bin-2.05.
Upgrading cage cage2 cpuA from rev 1.46 to revision in file
/opt/tpd/fw/cage/dc2/lbod_fw.bin-2.05.
Upgrading cage cage3 cpuA from rev 03 to revision in file
/opt/tpd/fw/cage/dc3/dc3_fw.bin-04.
Skipping cage cage4 cpuA already up to date at rev 2.05
Skipping cage cage5 cpuA & cpuB already up to date at rev 04
NOTES
Before executing the upgradecage command, issue the showcage command to obtain the
names of the drive cages in the system.
When the upgradecage command is issued, the drive cage becomes temporarily unavailable.
The cage automatically restarts following the firmware update, and may briefly disrupt the
loops during the restart. It is recommended showcage be used approximately one minute
after the update completes to ensure both loops to the cage are available again.