HP INTEGRITY RX3600 User Manual Page 309

  • Download
  • Add to my manuals
  • Print
  • Page
    / 356
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 308
Version: 1.04.12.00
(C) Copyright 2004 Hewlett Packard Development Company L.P.
*************************************************************
Updating controller in Seg: 1, Bus: 51, Dev: 4, Func: 0
Current firmware version 1.92Percentage completed: 100%
Activating firmware now, this may take several minutes.
Resetting and reinitializing controller.
Retrieving firmware version, this may take several minutes.
Current controller firmware version is 2.34.
NOTE: The UPDATE command will not prevent downgrade to a lower firmware version.
After updating the firmware, cycle the power on the system and on any external JBODS connected
to the Smart Array HBAs.
Exit status codes0: Success
UPDATE all
When “all” is specified, the utility downloads the firmware image to all the controllers to which
the firmware image applies and updates the remaining controllers. If an update operation fails
for a controller, the utility still updates the remaining controllers.
The example below shows the command to update all controllers for which the firmware image
file applies. The controllers for which the firmware image is not applicable are skipped. In this
example, the Smart Array 6400 controller is updated, and the Smart Array 5300 is skipped:
fs0:\> saupdate UPDATE all CYBORG234.BIN
Replace CYBORG234.BIN with the name of your firmware file.
The following screen displays, showing the controllers that are updated and skipped:
*************************************************************
Smart Array Offline Firmware Update Utility
Version: 1.04.12.00
(C) Copyright 2004 Hewlett Packard Development Company L.P.
*************************************************************
Updating controller in Seg: 1, Bus: 51, Dev: 4, Func: 0
Current firmware version 1.92
Percentage completed: 100%
Activating firmware now, this may take several minutes.
Resetting and reinitializing controller.
Retrieving firmware version, this may take several minutes.
Current controller firmware version is 2.34.
************************************************************
Smart Array Offline Firmware Update Utility
Version: 1.04.12.00
(C) Copyright 2004 Hewlett Packard Development Company L.P.
*************************************************************
Firmware Image is not suitable for HP Smart Array
5300 Controller at Seg: 1, Bus 20, Dev: 1, Func:0
After updating the firmware, cycle the power on the system and on any external JBODS connected
to the Smart Array HBAs.
HELP or ?
Use HELP or ? to display usage text, program version number, and build date:
Enter: saupdate HELP
or
Smart Array P400, P600 and P800 Controllers 309
Page view 308
1 2 ... 304 305 306 307 308 309 310 311 312 313 314 ... 355 356

Comments to this Manuals