Support S3, S4 and S5
ACPI status
Hardware monitor capability
CPU fan speed control
Network Interface
Integrated Intel WG82567LM Gigabit Network Connection
Intel Gigabit CT Desktop NIC (optional)
Wireless
MT: Wireless 802.11b/g/n PCIe Card (full height bracket)
SFF: Wireless 802.11b/g/n PCIe Card (half height bracket)
Power Supply
MT: ATX Power Supply – Passive PFC
SFF: Custom Power Supply – Passive PFC
Passive Power Factor Correction (PFC/NPFC) – with line switch set to 230V – No PFC in
115V line switch position
90 to 140VAC, or 180 to 264VAC operating voltage range
100 to 127VAC, or 200 to 240VAC rated voltage range
50-60 Hz rated line frequency
47-63 Hz operating line frequency range
MT: 300 watt maximum rated power
SFF: 250 watt maximum rated power
80-mm power supply fan – variable speed for optimum acoustics
Power Conservation
‘Energy Saver‘
APM 1.2 support
Screen blanking
Hard drive 'Idle' mode
System Idle mode
~2 watt power consumption in ES mode - suspend to RAM (S3) (instantly available PC)
Processor/Cache memory power-down (S3)
System Environmental
Specs
Values are subject to change without notification and are for reference only.
Performance of system, options, and ancillary equipment will vary depending on the
system configuration.
Levels presented do not account for non-HP/Compaq installed hardware.
Ambient Air
Temperature
Operating
MT: Operating 41° to 95°F (5 to 35°C) (Test 0
to 104°F (40°C));
SFF: 50° to 95°F (10° to 35°C) at sea level
with an altitude de-rating of 1.0°C per every
1000 ft (300 m) above sea level to a
maximum of 10000 ft (3000 m), no direct
sustained sunlight. Maximum rate of change
is 77°F/Hr (25°C/Hr). The upper limit may be
limited by the type and number of options
installed.
Storage
MT: Storage: 90% RH @ 60°C for 12 hours
(Non-condensing)
SFF: –22° to 140°F (–30° to 60°C) –
Maximum rate of change: 410°F/Hr
(210°C/Hr).
Humidity
Operating
MT: 15% to 80% relative humidity (Rh), 35°C
non-condensing
SFF: 10% to 90% relative humidity (Rh), 86°F
(30°C) maximum wet bulb temperature, non-