condensing
Storage
MT: 90% relative humidity (Rh), 60°C for
12 hours, non-condensing
SFF: 0 to 10,000 feet (0 to 3048 meters) -
This value may be limited by the type and
number of options installed. Maximum
allowable altitude change rate is 1,000 ft/min
(304.8 m/min).
Altitude
Operating
MT: 0 to 7,500 feet (0 to 2286 meters) – This
value may be limited by the type and number
of options installed.
SFF: 0 to 10,000 feet (0 to 3048 meters) –
This value may be limited by the type and
number of options installed. Maximum
allowable altitude change rate is 1,000 ft/min
(304.8 m/min).
Non-Operating
MT: 0 to 15,,000 feet (0 to 4572 meters)
SFF: 0 to 30,000 feet (0 to 9,144 meters) –
Maximum allowable altitude change rate is
1200 ft/min (365.76 m/min).
Shock
Listed are the levels of shock the product can withstand with No
damage being incurred. The values represent peak input acceleration
during an 2~3 ms half-sine shock pulse, 11 ms trapezoidal shock
pulse.
Non-Operating
MT:
35G's (Half-sine Shock)
35G's (Trapezoidal Shock)
SFF:
35G's (Half-sine Shock)
40G's (Trapezoidal Shock)
Vibration
Listed are the levels of vibration the product can withstand with No
damage being incurred. The values represent a flat random vibration
input acceleration profile across the given frequency range.
Operating
MT: Random Operating: ~0.21Grms (5-500
Hz) Swept Sine: 0.5g (5-500Hz) 5 min. dwell
at 4 resonance's 5Hz to 300Hz, (0.25G's
nominal).
SFF: Random vibration at
5Hz to 300Hz, (0.25G's nominal).
Non-Operating
MT: ~2.09Grms (5-500Hz), Non-Operational
SFF: Random vibration at 0.008G²/Hz,
10Hz to 500Hz, (2 Grms nominal).
Acoustic Noise
Listed are the declared A-WEIGHTED SOUND POWER LEVELS
(LWAd) and declared average desktop seated operator position A-
WEIGHTED SOUND PRESSURE LEVELS (LpAm) when the product is
operating in a 73.4°F (23°C) ambient environment. Noise emissions
were measured in accordance with ISO 7779 (ECMA 74) and declared
in accordance with ISO 9296 (ECMA 109).
MT
: IDLE (Fixed disk
drive spinning)
SFF
: IDLE (Fixed disk
drive spinning)
LWAd = 3.7 Bels,
Desktop Average LpAm = 25 dBA
LWAd = 4.3 Bels,
Desktop Average LpAm = 32 dBA