HP D2D2502i User's Guide Page 153

  • Download
  • Add to my manuals
  • Print
  • Page
    / 178
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 152
current value remains unchanged. If this parameter is changed, the number of slots and number
of drives currently defined must be less than that defined by the library emulation. If this is not
the case, an error message is generated.
DriveEmulation This optional parameter defines the type of physical drive the virtual tape
drive will emulate. The values are defined in the Command Syntax. If not defined, the current
value remains unchanged. If this parameter is changed, the emulation type only applies to
new drives which are added to the library; the emulation types of the current virtual drives in
the library remain unchanged.
DrivePort This optional parameter allows different port ranges to be assigned to the robotic
arm and virtual drives and is only valid if the interface has been defined as Fiber Channel. it
defines the physical Fibre Channel ports via which commands to the virtual drives will be
transmitted. The value is a number, or a set of numbers separated by commas, that correspond
to the ports as defined by the vtl show ports command. If more than one port number is
defined, the ports are alternatively assigned to the drives in the library in a round robin fashion.
If not defined, the current value remains unchanged. A value of zero indicates no port should
be assigned to the Fibre Channel interface.
NoOfSlots This optional parameter defines the number of cartridge slots in the virtual library.
The number of slots must conform to the library emulation type. The value has a maximum of
16384 characters. If not defined, the current value remains unchanged. If the value of the
number of slots is greater than the maximum allowed by the Library emulation, an error is
generated.
NoOfDrives This optional parameter defines the number of drives in the virtual library. The
number of drives must conform to the library emulation type. The value has a maximum of
192 characters. If not defined, the current value remains unchanged. If the value of the number
of drives is greater than the maximum allowed by the Library emulation, an error is generated.
Port This optional parameter defines the physical Fibre Channel ports which will be assigned
to the library’s robotic arm and virtual drives and is only valid if the library interface is Fibre
Channel. The value is defined by a number or a set of numbers (separated with commas)
corresponding to the ports as defined by the vtl show ports command. All the ports listed
are assigned to the robotic arm. If only one port value is assigned to this parameter, the port
is assigned to all the virtual drives in the library. If more than one part number is defined, the
ports are alternatively assigned to the drive in the library in a round robin fashion. A value
of zero indicates that no port should be assigned to the Fibre Channel interface. If not defined,
the current value remains unchanged.
iSCSIName single-node only. This parameter defines the iSCSI initiator name and is required
if the interface is iSCSI. If the VTL’s interface is not iSCSI, defining this will generate an error.
The value is a text string with a maximum of 224 characters. If not defined, the current value
remains unchanged.
iAuthenticationEnable single-node only. This optional parameter determines if the CHAP
(challenge handshake authentication protocol) initiator log on is enabled. The value for this
parameter is either yes or no. If not defined, the current value remains unchanged.
iUserName single-node only. This optional parameter defines the initiator user name for the
CHAP (challenge handshake authentication protocol) and is only valid if the interface is iSCSI.
The value is a text string with a maximum of 224 characters. If not defined, the current value
remains unchanged.
iSecret single-node only. This parameter defines the initiator secret for the CHAP (challenge
handshake authentication protocol) and is only valid if the interface is iSCSI. The value is a
text string with a maximum of [TBD] characters. If not defined, the current value remains
unchanged.
vtl modify library 153
Page view 152
1 2 ... 148 149 150 151 152 153 154 155 156 157 158 ... 177 178

Comments to this Manuals