BarcodeLength This optional parameter defines the total number of characters in the barcode
used by the cartridges in the virtual tape library created by this command. The value is either
6 or 8. If not included, a default value of 8 is used.
Requirements for Command Execution
The command entry must conform to the command syntax.
All object values must be valid; see the object descriptions for details.
All parameter values must be valid; see the parameter descriptions for details.
Successful Command Output
Upon successful completion of the command, the following is displayed:
Command Successful
Command Operation during Abnormal Conditions
If any of the command execution requirements fail, command execution terminates. The
cartridge is not added to the library and one of these error messages is displayed:
Command Failed Did not conform to the correct command syntax
vtl create library [SETX] [name <string>] [interface { iSCSI |
FC }] [ LibEmulation { Generic | MSL2X24 | MSL4X48 | MSL8X96 |
EML | ESL } ] [ DriveEmulation { LTO2 | LTO3 | LTO4 | LTO5 |
UltriumVT } ] [ NoOfSlots <number> ] [ CartSize {10 | 25 | 50 |
100 | 200 | 400 | 800 | 1000 | 1200 | 1400 | 1600 | 3200 } ] [
NoOfDrives <number> ] [ Port <number> [,<num>]] [iSCSIname
<string> ] [iAuthenticationEnable {yes | no}] [ iUsername <string>
] [ iSecret <string> ] [tAuthenticationEnable {yes | no}] [
tUsername <string> ] [ tSecret <string> ] [ BarcodeLength { 6 |
8 } ]
Command Failed The entry does not conform to command syntax.
The number of double quotes () is odd.
Command Failed The service set <SETX> is invalid
Command Failed The service set <SETX> does not exist
Command Failed Invalid Parameter: <parameter> value: <value>
Command Failed The name must be equal to or less than 30
characters
Command Failed The interface <interface> is invalid
Command Failed The library port <LibPort> is invalid
Command Failed The library emulation <LibEmulation> is invalid
Command Failed The drive emulation <DriveEmulation> is invalid
Command Failed The drive port <DrivePort> is invalid
Command Failed The number of slots must conform to library
emulation type
Command Failed The number of slots must be between 0 and 16384
Command Failed The size of the cartridges must be 10, 25, 50,
100, 200, 400, 800, 1000, 1200, 1400, 1600 or 3200