Requirements for Command Execution
• The command entry must conform to the command syntax.
• All object values must be valid; see the object descriptions for details.
• All parameter values must be valid; see the parameter descriptions for details.
Successful Command Output
Upon successful completion of the command, the following is displayed:
Command Successful
Command Operation during Abnormal Conditions
If any of the command execution requirements fail, command execution terminates. The cartridge
is not added to the library and one of these error messages is displayed:
• Command Failed - the command does not conform to the correct command
syntax “vtl create cartridge [SETX ] LIBX { ALL | slot <number> |
mail <number> } [WriteProtect { yes | no}] [barcode <string>]
[CartSize {10 | 25 | 50 | 100 | 200 | 400 | 800 | 1000 | 1200 | 1400
| 1600 | 3200}]”
• Command Failed — The service set <SETX> is invalid
• Command Failed – The service set <SETX> does not exist
• Command Failed – The library <LIBX> is invalid
• Command Failed – The library <LIBX> does not exist
• Command Failed – “ALL” slot or a mail must be defined
• Command Failed – The slot <slot> does not exist in library
• Command Failed – The mail slot <mail> does not exist in library
• Command Failed – The slot <slot> is not empty
• Command Failed – The mail slot <mail> is not empty
• Command Failed – The barcode string does not conform to the library
barcode parameters
• Command Failed – The barcode string must consist of 8 alphanumeric
characters
• Command Failed – The cartridge size must be 10, 25, 50, 100, 200,
400, 800, 1000, 1200, 1400, 1600 or 3200
Examples
# vtl create cartridge SET1 LIB1 ALL
Command Successful
# vtl create cartridge LIB1 slot 2
Command Successful
vtl create cartridge 139
Comments to this Manuals