HP ProLiant 1200 W Power Supply
Specification Value
Input requirements
Rated input voltage
100 to 120 VAC, 200 to
240 VAC
Rated input frequency
50 Hz to 60 Hz
Rated input current
10 A at 100 VAC
4.9 A at 200 VAC
Rated input power
930 W at 100V AC input
1348 W at 200V AC input
BTUs per hour
3530 at 120V AC input
4600 at 200V to 240V AC input
Power supply output
Rated steady-state power
800 W at 100V AC input
900 W at 120V AC input
1200 W at 200V to 240V AC
input
Maximum peak power
800 W at 100V AC input
900 W at 120V AC input
1200 W at 200V to 240V AC
input
HP ProLiant 750 W Power Supply
Specification Value
Input requirements
Rated input voltage
100 to 120 VAC, 200 to
240 VAC
Rated input frequency
50 Hz to 60 Hz
Rated input current
8.9 A at 100 VAC
4.3 A at 200 VAC
Rated input power
857 W at 100V AC input
824 W at 200V AC input
BTUs per hour
2925 at 100V AC input
2812 at 200V AC input
Power supply output
Rated steady-state power
750 W at 100V to 120V AC input
750 W at 200V to 240V AC input
Maximum peak power
750 W at 100V to 120V AC input
750 W at 200V to 240V AC input
HP ProLiant 460 W Power Supply
Specification Value
Input requirements
Rated input voltage
100 to 120 VAC, 200 to
240 VAC
Rated input frequency
50 Hz to 60 Hz