o ManualIf your facility prefers static IP address assignment, you can individually change each
of the server blade iLO 2 ports and interconnect module management ports to unique static
addresses or use EBIPA to assign a range of static IP addresses to individual server blade and
interconnect module bays.
o EBIPAWhen a server blade or interconnect module is inserted into a bay that has EBIPA
enabled, that management port will get the specific static IP address from the Onboard
Administrator if that device is configured for DHCP.
The administrator sets an independent range for server blade bays and interconnect module bays using
the Onboard Administrator EBIPA setup wizard. The first address in a range is assigned to the first bay
and then consecutive bays through the range.
For example, if you set the server bay EBIPA range to 16.100.226.21 to 16.100.226.36, the iLO 2 in
device bay #1 will be assigned 16.100.226.21 and the iLO 2 in device bay #12 is assigned
16.100.226.32. If you set the interconnect bay EBIPA range to 16.200.139.51 to 16.209.139.58, the
interconnect module management port in interconnect bay #1 will be assigned 16.200.139.51 and the
interconnect module management port in interconnect bay #7 will be assigned 16.200.139.57.
To enable EBIPA settings for the server bays in this enclosure, select Enable Enclosure Bay IP Addressing
for Server Bay iLO 2 Processors and then enter the following information.