Hp XP P9500 Storage User Manual Page 170

  • Download
  • Add to my manuals
  • Print
  • Page
    / 367
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 169
SolutionsError ContentsError Code (SSB2)
Confirm the value immediately below LDEV
Capacity in the Expand Virtual Volumes
window.
Because the shared memory capacity is not
enough to increase the specified capacity, the
operation was rejected.
0xaf2c
Wait until formatting of the specified volume is
finished, or see “Using Thin Provisioning and
Because the specified THP V-VOL was used by
other software or was being formatted, the
operation was rejected.
0xaf2e
Smart Tiers with other P9500 products” (page
68) and confirm whether the THP V-VOL is used
with software in which that the THP V-VOL
capacity cannot be increased.
Re-execute the operation after the microcode is
replaced.
Because the THP V-VOL capacity was increased
when the microcode was replaced, the
operation was rejected.
0xaf2f
Re-execute the raidcom extend ldev
command without specifying the -cylinder
option.
Because the raidcom extend ldev
command was executed with specifying the
-cylinder option to the THP V-VOL for the
open system, the operation was rejected.
0x0b2b
Errors when operating RAID Manager (Data Retention, SSB1:B9BF/B9BD)
DescriptionError Code
(SSB2)
The setting failed because the specified volume does not exist.B9BD
The specified volume is a command device.B9C2
The command was rejected due to one of the following reasons:B9C4
The specified volume is a P-VOL or S-VOL of Snapshot.
The specified volume is a virtual volume.
The specified volume is a pool volume.
The specified volume is an S-VOL of Continuous Access Journal.
The specified volume is a journal volume.
The specified volume is reserved for the Auto LUN function.
The specified volume is a P-VOL or S-VOL of Business Copy.
The consumed capacity exceeded the licensed capacity.
The access attribute cannot be changed because the data retention term is set.
The specified volume is a command device.
The specified volume is in the PAIR or COPY status.
The specified volume does not exist.
The S-VOL Disable attribute is set to the specified volume.
The reserve function cannot be canceled using RAID Manager.
Data Retention is not installed.B9C7
The consumed capacity exceeded the licensed capacity.B9C9
Either:B9CA
More than 60 years are set as the data retention days, or.
Another interface updated the settings while Data Retention was changing the settings (Java
conflicted with the other interface).
The retention term cannot be set because the access attribute is read/write.B9CB
170 Troubleshooting
Page view 169
1 2 ... 165 166 167 168 169 170 171 172 173 174 175 ... 366 367

Comments to this Manuals

No comments