Hp XP P9500 Storage User Manual Page 107

  • Download
  • Add to my manuals
  • Print
  • Page
    / 367
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 106
Changing pool thresholds
1. In the Remote Web Console main window, in the Storage Systems tree, select Pool.
The pool name appears below Pool.
2. From the Pools table, select the pool for which you want to change the threshold.
Select multiple pools using the Shift key (if the pools are adjacent), or using the Ctrl key (if the
pools are not adjacent).
3. Click More Actions, and then select Edit Pools.
4. In the Edit Pools window, check Warning Threshold or Depletion Threshold.
5. Type the threshold values in the text box.
The threshold value can be within the range of values indicated below the text box. The
Depletion Threshold value can be equal to or greater than the Warning Threshold.
NOTE: For a pool where only one user-defined thresholds is set, the system assigns the
system threshold (fixed at 80%). The lower value of the single user-defined threshold and the
fixed system threshold are set as the Warning Threshold; the higher value of the two is set as
the Depletion Threshold. After the Depletion Threshold is defined, the system threshold cannot
be enabaled again. If the threshold is changed once, the system threshold is not enabled
again.
A SIM code is reported when the pool usage capacity exceeds the threshold changes.
6. Click Finish.
7. In the Confirm window, confirm the settings, in Task Name type a unique name for this task
or accept the default, and then click Apply.
If Go to tasks window for status is checked, the Tasks window opens.
Changing the pool subscription limit
1. In the Remote Web Console main window, in the Storage Systems tree, select Pool.
2. From the Pools table, select the pool for which you want to change the subscription limit.
Select multiple pools using the Shift key (if the pools are adjacent), or using the Ctrl key (if the
pools are not adjacent).
3. Click More Actions, and then select Edit Pools.
4. In the Edit Pools window, check Subscription Limit, and then type the subscription limit
percentage.
If the subscription limit is blank, then it is disabled, and any amount of THP V-VOLs can be
created regardless of the pool free capacity.
5. Click Finish.