Hp Storage Mirroring Software User Manual Page 291

  • Download
  • Add to my manuals
  • Print
  • Page
    / 339
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 290
A - 28
Schedule End
Schedule Start
Command SCHEDULE END
Description Sets criteria to end the transmission of data from the source to the target
Syntax
SCHEDULE <target_machine> END [ DURATION = <number> <time_units> ][ BYTES = <bytes> ]
Options ! target_machine—Name of the target machine
! number—Any number indicating the length of time before the transmission ends
! time_units—Minutes (min), hours (hr), or days (day)
! bytes—Number of bytes transmitted before the transmission ends
Examples
! schedule jersey end duration=3 hr
! schedule philly end bytes=1500000
Notes If you use both of the end options, duration and bytes, the transmission will be stopped when
the first end option value is met.
Command SCHEDULE START
Description Sets criteria to start the transmission of data from the source to the target
Syntax
SCHEDULE <target_machine> START [STARTTIME = <mm/dd/yy> <hh:mm>] [MEMLIMIT =
<percent>]
[QUEUESIZE = <bytes>] [EVERY <number> <time_units>]
Options
! target_machine—Name of the target machine
! mm/dd/yy—Date in month/day/year format indicating when the transmission will begin
! hh:mm—Time in hour:minute format using the 24 hour clock indicating when the transmission
will begin
! percent—Any number between 0 and 100 indicating the percentage of the disk queue and system
memory that must be in use to initiate the transmission process
! bytes—Number of bytes that must be in the source queue and system memory to initiate the
transmission process
! number—Any number indicating how often the transmission process will be repeated
! time_units—Minutes (min), hours (hr), or days (day)
Examples
! schedule jersey start starttime=3/11/01 03:30
! schedule philly start queuesize=400000
! schedule jersey start starttime=3/03/01 18:00, every 8 hr
! schedule philly start memlimit=25, queuesize=150000000
Notes ! The start option EVERY cannot be used by itself and cannot be the first option in a string of
options.
! If you use more than one start option, the transmission will begin when the first start option
value is met. Additionally, each option after the first must be separated by a comma, as illustrated