EXAMPLES
The following example displays new customer alerts on a system:
cli% showalert -n
Id : 1
State : New
Message Code: 0x2200de
Time : 2008-07-17 20:14:29 PDT
Severity : Degraded
Type : Component state change
Message : Node 0, Power Supply 1, Battery 0 Degraded (Unknown)
Id : 2
State : New
Message Code: 0xe000c
Time : 2008-07-17 20:15:31 PDT
Severity : Informational
Type : Cluster shutdown after system recovery completion
Message : System recovery completed for node 0 (reason Power Loss)
2 alerts
NOTES
• Set the status of alerts by issuing the setalert command. See “setalert” (page 271) for more
information.
• Alerts can be removed by issuing the removealert command. See “removealert” (page 228)
for more information.