The HP ProLiant DL180 G6 is a low cost high capacity storage optimized 2-way server that delivers on a history of design excellenceand 2U density for
WarrantyThis product is covered by a global limited warranty and supported by HP Services and a worldwidenetwork of HP Authorized Channel Partners. Ha
HP Insight Controlmanagement softwareHP Insight Control forLinuxHP Insight Control for Linux, as a product option, delivers essentialinfrastructure ma
High PerformanceClustersHP Cluster PlatformsHP Cluster Platforms are specifically engineered, factory-integrated large-scale ProLiant clusters optimiz
Service and SupportHP Technology Services for Industry Standard Servers and BladeSystemCapitalizing on HP ProLiant server and HP BladeSystem capabilit
Standard Care PackagePackage that maintains high level of server availabilityHP ProLiant Server Hardware InstallationProvides for the basic hardware i
Four Drive Serial ATA (SATA) ModelsNOTE: For the Standard Features shipped in the "Factory Integrated Models", please see the "Configur
Optical DriveNone ship standardPower Supply460W common slot, high efficiency power supplyForm FactorRack (2U)WarrantyServer Warranty includes 3-Years
Form FactorRack (2U)WarrantyServer Warranty includes 3-Years Next Business Day Parts replacement, 0-Years Labor, 0-Years Onsite supportTwenty Five Dri
WarrantyServer Warranty includes 3-Years Next Business Day Parts replacement, 0-Years Labor, 0-Years Onsite supportQuickSpecsHP ProLiant DL180 Generat
The ProLiant Smart Buy program offers a collection of promotional server and option products that are configured with SMB in mind,offered at discounte
NOTE: For the Standard Features shipped in the Factory Integrated Models, please see the "Configuration Information - FactoryIntegrated Models&qu
NOTE: This section lists some of the steps required to configure a Factory Integrated Model. To ensure only valid configurations areordered, HP recomm
Step 2: Choose Required Options (only one of the following from each list unless otherwisenoted)HP ProcessorsNOTE: If 2 processors are desired, select
HP Drive Cage OptionsHP 2U G6 4HDD CAGE Kit, FIO506926-B21HP 2U G6 8HDD CAGE Kit, FIO506927-B21HP 2U G6 12HDD CAGE Kit, FIO506928-B21HP 2U 8SFF HDD CA
NOTE: Some options may not be integrated at the factory. To ensure only valid configurations are ordered, HP recommends the use ofan HP approved confi
HP DL180 G6 Intel® Xeon® E5606 (2.13GHz/4-core/8MB/80W) Processor Kit635583-B21HP DL180 G6 Intel® Xeon® E5603 (1.60GHz/4-core/4MB/80W) Processor Kit63
HP 16GB (1x16GB) Dual Rank x4 PC3L-10600 (DDR3-1333) Registered CAS-9 LPMemory Kit627812-B21Unregistered with ECC UDIMMs HP 1GB (1x1GB) Single Rank x8
HP 146GB 6G SAS 15K rpm SFF (2.5-inch) Dual Port Enterprise 3yr Warranty Hard Drive512547-B21HP 146GB 6G SAS 15K rpm SFF (2.5-inch) Dual Port Enterpri
HP 1TB 3G SATA 7.2K rpm SFF (2.5-inch) Hot Plug Midline 1yr Warranty Hard Drive S-Buy625609-S21HP 500GB 3G SATA 7.2K rpm SFF (2.5-inch) Midline 1yr Wa
HP NetworkingGigabit Ethernet Adapters HP NC112T PCI Express Gigabit Server Adapter503746-B21HP NC360T PCI-E Dual Port Gigabit Server Adapter412648-B2
NOTE: Some options may not be integrated at the factory. To ensure only valid configurations are ordered, HP recommends the use ofan HP approved confi
Cache MemoryOne of the followingdepending on Model12 MB Level 3 cache (L5630,E5620,X5650)4 MB Level 3 cache (E5506)ChipsetIntel® 5520 ChipsetNOTE: For
online or via fax in order to obtain the license activation key(s). Includes one year of 24x 7 HP Software Technical Support Service.NOTE: For additio
HP I/O AcceleratorOptionsHP 160GB Single Level Cell PCIe ioDrive for ProLiant ServersNOTE: A low-profile PCI bracket is included for use in low-profil
HP Smart Array P411/256 2-ports Ext PCIe x8 SAS Controller462830-B21HP Smart Array P411/512 BBWC 2-ports Ext PCIe x8 SAS Controller462832-B21HP Smart
(Smart Array P212 Controller)http://h18000.www1.hp.com/products/quickspecs/13201_div/13201_div.html(Smart Array P410 Controller)http://h18000.www1.hp.
HP Ultrium 920 SAS Internal Tape DriveNOTE: For installation into 1U SAS Rack-Mount Kit (AE459B) or 3U SAS Rack-Mount Kit(AG576B). No peripheral bay a
HP Storage OptionsFibre Channel HBANOTE: The following is a list of all Fibre Channel Host Bus Adapters for Windows andLinux. For detailed compatibili
HP Uninterruptible PowerSystemsHP Rack-mountable UPSR7000 Uninterruptible Power System (UPS) HP R7KVA 4U 50A High Voltage Uninterruptible Power System
HP Power DistributionUnitsMonitored PDUsHP Monitored Power Distribution Unit: Full Rack Version HP 8.6kVA 24A Single Input Three Phase Monitored Power
HP Rack SeriesHP Rack 10000 G2 Series (Carbon/Graphite Metallic)HP 10642 G2 1200mm deep Shock RackAF092AHP 10647 G2 1200mm deep Shock RackAF094AHP 106
HP Rack OptionsHP Server Console SwitchesHP Server Console 0x2x8 Port Analog SwitchAF616AHP Server Console 0x2x16 Port Analog SwitchAF617ANOTE: Please
Expansion SlotsSlot NumberBus SpeedBus Number*DeviceNumber**Hot Plug(Y/N)Notes1x16 PCI-Express6 0NLow Profile2x8 PCI-Express5 0NFull LengthFull Height
NOTE: Memory configurations listed do not apply to "Factory Integrated Models".HP ProLiant DL180 G6Standard Memory (depending on model)4GB (
DIMM Type ->Registered DIMMS (RDIMMs)Unbuffered with ECC DIMMs(UDIMMs)DIMM Rank ->SingleRank(1R)Dual Rank (2R)Quad Rank (4R)SingleRank(1R)Dual R
12 DIMM SLOTS (6 per CPU node) CPU1 CPU2 slot #population orderslot #population order Chnl 11D1DChnl 12A2A Chnl 23E3EChnl 24B4B C
Standard memory replaced with optional memory (1 CPU model)RDIMM maximum configuration96GB, consisting of six (6) 16GB quad-rank PC3-8500 RDIMMs CPU1
UDIMM maximum configuration (2 CPU model)48GB, consisting of twelve (12) 4GB dual-rank PC3-10600 UDIMMs CPU1 CPU2 slot #population orderslot #populat
HP 4GB (1x4GB) Quad Rank x8 PC3-8500 (DDR3-1066) Registered CAS-7 Low PowerMemory Kit500660-B21HP 4GB (1x4GB) Single Rank x4 PC3-10600 (DDR3-1333) Reg
8 Drive Cage with DVD-Drive bay 1-8Eight 3.5" Hot Plug SAS/SATA Hard Drive Bays9DVD-ROM, DVD RW12 Drive Cage 1-12Twelve 3.5" Hot Plug SA
HP Smart Array P410/512 MB FBWC ControllerHP Smart Array P410/1G FBWC ControllerHP Smart Array P812/1G FBWC ControllerHP Smart Array P800/512 BBWC Con
SSD200GB 3G SATA MLC SFFSSD100GB 3G SATA MLC SFFSSDdrive cageHP Smart Array P212/256 MB ControllerHP Smart Array P410/256 MB ControllerHP Smart Array
HP Smart Array P410/512 MB BBWC ControllerHP Smart Array P410/512 MB FBWC ControllerHP Smart Array P410/1G FBWC ControllerHP Smart Array P812/1G FBWC
NOTE: A minimum of 256 MB cache, battery kit, and Smart Array Advanced Pack License Key upgrade (P/N:516471-B21) is required to enable RAID 6, 6+0NOTE
6G SAS Hot Plug Enterprise Performance Solid State Drives QuantitySupportedPositionSupportedController400GB 6G SAS SLC 200GB6G SAS SLCUp to 41-4HP Sma
DAT 72DAT 160DAT 3201U USB Rack-Mount Kit HP SAS Tape DrivesDAT 160DAT 320LTO-2 Ultrium 448LTO-3 Ultrium 920LTO-4 Ultrium 1760LTO-4 Ultrium 1840LTO-
HP D2D Backup Systems,iSCSID2D2500iD2D4000iExternalEmbedded Network Controller. If the server requires a hardwareiSCSI initiator, the QLogic QL
HP 460W Common Slot Gold Hot Plug Power Supply KitPart Number503296-B21Input Voltage Range (Vrms)100 to 240Frequency Range (Nominal) (Hz)50/60Nominal
HP 460W Common Slot Platinum Hot Plug Power Supply KitPart Number593188-B21Input Voltage Range (Vrms)100 to 240Frequency Range (Nominal) (Hz)50/60Nomi
HP 1200W Common Slot -48VDC Hot Plug Power Supply KitPart Number437573-B21Input Voltage Range (Vrms)36-72Frequency Range (Nominal) (Hz)DCNominal Input
System UnitDimensions (H x W x D)(with bezel)3.45" x 17.64" x 28.23" in (8.76 x 44.80 x 71.71 cm)Weight(approximate)Maximum(all hard dr
System performance may be reduced if operatingwith a fan fault or above 30°C (86°F).Non-operating-30° to 60°C (-22° to 140°F). Maximum rate ofchange i
Smart Array P212ControllerDisk Drive and EnclosureInterface3G SAS (Serial Attached SCSI)1.5G SATA (Serial ATA)SAS Connectors1 internal/1 external (Min
Environment-friendlyProducts and ApproachEnd-of-life Managementand RecyclingHewlett-Packard offers end-of-life HP product return, trade-in, and recycl
Industry StandardComplianceACPI V2.0 CompliantPCI 2.2 CompliantPXE SupportWOL SupportMicrosoft® Logo certificationsIPMI 2.0 CompliantServer Power Cord
System Fans4 system fans ship standard; Non-hot plug, Non-redundantNOTE: Redundant fan kit (P/N 516009-B21) available for purchase.Operating Systems a
agents, providers, and a SmartStart 'like' deployment CD called Easy Set-upwhich greatly simplifies server set-up. Additionally the DL100 an
Array Configuration Utility (ACU) has been combined with ArrayDiagnostics Utility (ADU) to offer both configuration of array controllersand storage de