IGP/VGL (Code V) Emulation
105
Truncate Alpha
When enabled, this parameter prevents the printing of Error 48 (Element Off
Page Error) if alphanumeric data, including spaces, extends beyond the right
side of the form.
True Vert 1/10
Disable. A vertical 1/10 of an inch parameter is used as 7/72 of an inch.
The absolute move is slightly smaller than expected. For example, a one
inch move would be 70/72 of an inch. Vertical moves that have the same
value will be identical in length.
Enable. A vertical 1/10 of an inch parameter is used as 1/10 of an inch.
Rounding occurs to the nearest 1/72 of an inch. This can cause vertical
moves that have the same value to differ by
± 1/72 of an inch.
Absorb after ^PY
Absorb Motion. Prevents paper motion following a system terminator in
a graphics ^PY command.
Absorb All. The system ignores all the data and terminator until a
host-generated terminator is detected.
Disable. System terminators following a graphics command are sent to
the printer and result in paper motion.
UPC Descenders
Disable. UPC/EAN bar codes are printed without descenders if there is
no human readable data.
Enable. UPC/EAN bar codes are printed with descenders, even if there is
no human readable data.
Rot. Char Size
Adjusted. Rotated (clockwise/counterclockwise), expanded characters
have a different size than an unrotated character with the same size
parameters.
Not Adjusted. Rotated, expanded characters will be the same size as
unrotated characters with the same size parameters.
Ignore Spaces
Disable. Trailing spaces are not deleted from alphanumeric elements in a
graphics pass.
Enable. Trailing spaces are deleted from alphanumeric elements in a
graphics pass.