HP SN6000 User's Guide Page 119

  • Download
  • Add to my manuals
  • Print
  • Page
    / 122
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 118
Fabric OS Command Reference 91
53-1003108-01
bottleneckMon
2
To enable backend port credit recovery with the link reset threshold option and to display the
configuration:
switch:admin> bottleneckmon --cfgcredittools -intport \
-recover onLrThresh
switch:admin> bottleneckmon --showcredittools
Internal port credit recovery is Enabled with LrOnThresh
To disable backend port credit recovery and to display the configuration:
switch:admin> bottleneckmon --cfgcredittools \
-intport -recover off
switch:admin> bottleneckmon --showcredittools
Internal port credit recovery is Disabled
To examine a backend port for credit loss:
switch:admin> bottleneckmon --cfgcredittools \
-intport -recover off
switch:admin> bottleneckmon --cfgcredittools -intport -check 10/4,30
Started Credit loss Detection on slot 10 port 4 VC 30.
Please wait....
Detected credit loss.
Link Reset performed.
SEE ALSO creditRecovMode
Page view 118
1 2 ... 114 115 116 117 118 119 120 121 122

Comments to this Manuals

No comments