7-9
Interface Access and System Information
Interface Access: Console/Serial Link, Web, and Inbound Telnet
Note If you change the Baud Rate or Flow Control settings for the switch, you
should make the corresponding changes in your console access device. Oth-
erwise, you may lose connectivity between the switch and your terminal
emulator due to differences between the terminal and switch settings for these
two parameters.
All console parameter changes except events and inactivity-timer require that
you save the configuration with write memory and then execute boot before the
new console configuration will take effect.
For example, to use one command to configure the switch with the following:
VT100 operation
19,200 baud
No flow control
10-minute inactivity time
Critical log events
you would use the following command sequence:
Figure 7-4. Example of Executing the Console Command with Multiple Parameters
The switch implements the Event Log change immediately. The switch implements
the other console changes after executing
write memory and reload.