Hp Insight Management Agents User Manual Page 63

  • Download
  • Add to my manuals
  • Print
  • Page
    / 161
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 62
Fan Status displays the current status of the fans in the storage system backplane. The following
values are possible:
OK - The fans are installed and operating normally.
Degraded - At least one fan has failed, but there is still sufficient cooling capacity to allow
the storage system to continue. The failed fan should be replaced.
Degraded (Fan 1 Failed) - The fan in bay 1 has failed, but there is still sufficient cooling
capacity to allow the storage system to continue. The failed fan should be replaced.
Degraded (Fan 2 Failed) - The fan in bay 2 has failed, but there is still sufficient cooling
capacity to allow the storage system to continue. The failed fan should be replaced.
Failed - One or more fans have failed and there is insufficient cooling capacity to protect
the storage system from damage. The failed fans should be replaced.
Not Installed - This storage system backplane does not have a fan installed.
Not Supported - This storage system does not support reporting fan status through this
storage system backplane. The fan status is reported through the first backplane on this
storage system.
Unknown - The Storage Agent is unable to determine the fan status.
Speed displays the speed of the storage system backplane. The following values are possible:
Ultra3 - The storage system is capable of Ultra3 speeds.
Ultra320 - The storage system is capable of Ultra320 speeds.
SATA - The storage system is capable of SATA speeds.
Unknown - The Storage Agents are unable to determine the storage system backplane
speed. You may need to upgrade your software.
Drive Bays displays the number of bays on this storage system backplane.
Temperature Status displays the current temperature status of the storage system backplane.
The following values are possible:
OK - The temperature is within the normal operating range.
Degraded - The temperature is outside of the normal operating range.
Failed - The temperature has exceeded the safe operating temperature and could
permanently damage the storage system.
Not Monitored - This storage system does not support temperature monitoring.
Not Supported - This storage system does not support reporting the temperature status
through this storage system backplane. The temperature status is reported through the
first backplane on this storage system.
Unknown - The Storage Agent is unable to determine the temperature status.
Placement indicates the location of the storage system backplane. The following values are
valid:
Internal - The storage system backplane is located inside the external array storage system
chassis.
External - The storage system backplane is located outside the external array storage
system chassis in an external storage system.
Unknown - The Storage Agent could not determine the location of the storage system
backplane.
Storage Agent 63
Page view 62
1 2 ... 58 59 60 61 62 63 64 65 66 67 68 ... 160 161

Comments to this Manuals

No comments