HP PRO RX User Manual Page 15

  • Download
  • Add to my manuals
  • Print
  • Page
    / 21
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 14
Page 28
PRO RX Installation and User’s Manual
5.2.3. Create >2TB RAID Set for Windows XP (32bit):
If RAID is larger than 2TB, configure using multiple 2TB Volumes and then use
Windows to Span them together. This will end up with one drive letter of the full
capacity of the RAID.
1)
Create the RAID Set under RaidSet Functions by selecting all of the drives.
Create multiple Volume Sets under the VolumeSet Functions
Select the desired Volume Raid Level
Set the Select Volume Capacity to 2199GB
Set Greater Two TB Volume Support to No
Set Volume Initialization Mode to No Init (if applicable)*
Check the Confirm the Operation box
Click Submit
Repeat this step until all of the space are assigned.
* By setting the Volume Initialization Mode to No Init will result in immediate
availability of the RAID set, no need to wait for long initialization time.
Page 29
PRO RX Installation and User’s Manual
To view and confirm the Volume settings, select Information > RaidSet Hierarchy.
2)
In Windows Disk Management, make these volumes as Dynamic Disks and span
them together to make one large disk. Spanning is recommend as oppose to
striping. Striping in this configuration requires more system overhead and will
actually reduce performance. Use Spanning.