DVD Solution
DVD SolutionDVD Solution
DVD Solution
The DVD solution for Superdome requires the following components. These components are recommended per partition,
although it is acceptable to have only one DVD solution and connect it to one partition at a time. External racks A4901A
and A4902A must also be ordered with the DVD solution.
Superdome DVD Solutions
Superdome DVD SolutionsSuperdome DVD Solutions
Superdome DVD Solutions
Description
DescriptionDescription
Description
Part Number
Part NumberPart Number
Part Number
Option Number
Option NumberOption Number
Option Number
PCI Ultra160 SCSI Adapter or PCI-X Dual channel Ultra160 SCSI Adapter
A6828A or A6829A
0D1
PCI Ultra160 SCSI Adapter or PCI-X Dual channel Ultra 160 SCSI Adapter
(Windows Server 2003)
A7059A or A7060A
0D1
Surestore Tape Array 5300
C7508AZ
DVD (recommend one per partition)
C7499A
0D1
DDS-4 (opt.)/DAT40 (DDS-5/DAT 72 is also supported. Product number is
Q1524A)
C7497A
0D1
Jumper SCSI Cable for DDS-4 (optional)
1
C2978B
0D1
SCSI Cable
2,3
C2363B
2
0D1
SCSI Terminator
C2364A
0D1
0.5-meter HD HDTS68 is required if DDS-4 is used.
1.
5-meter multi-mode VH-HD68TS available now (C2365B #0D1) and can be used in place of the 10- meter cable on
solutions that will be physically compact
2.
10-meter multi-mode VH-HD68TS available now (C2363B, #0D1)
3.
Partitions
PartitionsPartitions
Partitions
Superdome can be configured with hardware partitions, (npars). Given that HP-UX 11i version 2 does not support virtual
partitions (vpars), Superdome systems running HP-UX 11i version 2 do not support vpars.
A hardware partition (npar) consists of one or more cells that communicate coherently over a high bandwidth, low latency
crossbar fabric. Individual processors on a single-cell board cannot be separately partitioned. Hardware partitions are
logically isolated from each other such that transactions in one partition are not visible to the other hardware partitions
within the same complex.
Each npar runs its own independent operating system. Different npars may be executing the same or different revisions of an
operating system, or they may be executing different operating systems altogether. Superdome supports HP-UX 11i version 2
(at first release), Windows Server 2003 (at first release + 2 to 4 months) and Linux (first release + 6 months) operating
systems.
Each npar has its own independent CPUs, memory and I/O resources consisting of the resources of the cells that make up
the partition. Resources (cell boards and/or I/O chassis) may be removed from one npar and added to another without
having to physically manipulate the hardware, but rather by using commands that are part of the System Management
interface. The table below shows the maximum size of npars per operating system:
HP UX 11i Version 2
HP UX 11i Version 2HP UX 11i Version 2
HP UX 11i Version 2
Windows Server 2003
Windows Server 2003Windows Server 2003
Windows Server 2003
Red Hat Enterprise Linux
Red Hat Enterprise LinuxRed Hat Enterprise Linux
Red Hat Enterprise Linux
AS 3 or Debian Linux
AS 3 or Debian LinuxAS 3 or Debian Linux
AS 3 or Debian Linux
Maximum size of npar
64 CPUs, 512 GB RAM 64 CPUs, 512 GB RAM
8 CPUs, 64 GB RAM
Maximum number of npars
16 16 16
For information on type of I/O cards for networking and mass storage for each operating environment, please refer to the
Technical Specifications section.
For licensing information for each operating system, please refer to the Ordering Guide.
Superdome supports static partitions. Static partitions imply that any npar configuration change requires a reboot of the
npar. In a future HP-UX and Windows release, dynamic npars will be supported. Dynamic npars imply that npar
configuration changes do not require a reboot of the npar. Using the related capabilities of dynamic reconfiguration (i.e. on-
line addition, on-line removal), new resources may be added to an npar and failed modules may be removed and replaced
while the npar continues in operation. Adding new npars to Superdome system does not require a reboot of the system.
Single System
Single SystemSingle System
Single System
Reliability/Availability
Reliability/AvailabilityReliability/Availability
Reliability/Availability
Features
FeaturesFeatures
Features
Superdome high availability offering is as follows:
NOTE:
NOTE: NOTE:
NOTE:
Online addition/replacement for cell boards is not currently supported and will be available in a future HP-UX
release. Online addition/replacement of individual CPUs and memory DIMMs will never be supported.)
QuickSpecs
HP Integrity Superdome Servers: 16-way, 32-way,
HP Integrity Superdome Servers: 16-way, 32-way,HP Integrity Superdome Servers: 16-way, 32-way,
HP Integrity Superdome Servers: 16-way, 32-way,
and 64-way
and 64-wayand 64-way
and 64-way
Configuration
DA - 11717 Worldwide — Version 2 — July 15, 2003
Page 8
Page view 7
1 2 3 4 5 6 7 8 9 10 11 12 13 ... 37 38

Comments to this Manuals

No comments