Hp Integrity Superdome Servers: 16-way User Manual

Browse online or download User Manual for Computers Hp Integrity Superdome Servers: 16-way. HP Integrity Superdome Servers: 16-way User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 38
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
QuickSpecs
HP Integrity Superdome Servers: 16-way, 32-way,
HP Integrity Superdome Servers: 16-way, 32-way,HP Integrity Superdome Servers: 16-way, 32-way,
HP Integrity Superdome Servers: 16-way, 32-way,
and 64-way
and 64-wayand 64-way
and 64-way
Overview
DA - 11717 Worldwide — Version 2 — July 15, 2003
Page 1
Page view 0
1 2 3 4 5 6 ... 37 38

Summary of Contents

Page 1 - QuickSpecs

QuickSpecsHP Integrity Superdome Servers: 16-way, 32-way,HP Integrity Superdome Servers: 16-way, 32-way,HP Integrity Superdome Servers: 16-w

Page 2

HP-UX: Serviceguard and Serviceguard Extension for RACWindows Server 2003: Microsoft Cluster Service (MSCS) - limited configurations supportedLinux: S

Page 3

access to the MP, and by its support for multiple geographically distributed console devices.Three common data center styles are:The secure site where

Page 4

WindowsWindowsWindowsWindowsTFor Windows Server 2003 customers desiring full visibility to the Superdome Windows partition, an IP console solution isa

Page 5

Functional Capabilities:Functional Capabilities:Functional Capabilities:Functional Capabilities:Allows local access to SMS by CE.Provides integrated c

Page 6

Manager enables these tasks to be distributed to multiple systems and delegated using role based security.HP-UX Kernel ConfigurationHP-UX Kernel Confi

Page 7

All other OpenView management tools, such as OpenView Operations, Service Desk, and Service Reporter, will be able tocollect and process information f

Page 8

Itanium2 based workstation or server running HP-UX 11i Version 2) in order to configure Linux partitions. Refer toHP-UX section above for key features

Page 9

Customer Provided PartCustomer Provided PartCustomer Provided PartCustomer Provided PartPDCA ProductPDCA ProductPDCA ProductPDCA Pro

Page 10

alternative cooling solutions may need to be explored by the customer. HP has teamed with Liebert to develop aninnovative data room cooling solution c

Page 11

They range from a 64-way Superdome with dual cord and dual UPS with main tie main to a 32-way Superdome with singlecord and single UPS. In all configu

Page 12

At A GlanceAt A GlanceAt A GlanceAt A GlanceThe latest release of Superdome, HP Integrity Superdome supports the new and improved sx1000 chip set. HP

Page 13

UPS Configuration GuidelinesUPS Configuration GuidelinesUPS Configuration GuidelinesUPS Configuration GuidelinesIn general, the sum of the "Watt

Page 14

customer is in need and/or interested in power protection for Superdome. APC will coordinate with the customer toensure the UPS is installed to meet t

Page 15

PerformancePerformancePerformancePerformance22222222The amount of memory on a cell should be evenly divisible by 4 GB if using 512-MB DIMMsThe amount

Page 16

Single SystemSingle SystemSingle SystemSingle SystemHigh AvailabilityHigh AvailabilityHigh AvailabilityHigh Availability36363636Each cell should have

Page 17

53535353Cluster lock must be powered independently of either cabinet.Cluster lock must be powered independently of either cabinet.Cluster lock must be

Page 18

The following applies to CPU iCOD on Superdome servers:The number of iCOD processors is selected per partition instead of per system at planning/o

Page 19

and Service Level Objectives. HP Utility Pricing encompasses just-in- time purchased capacity, pay-per-forecast based onplanned usage, as well as pay-

Page 20

This section applies to upgrades within HP Integrity Superdome systems. For information on upgrades from existing HP 9000 Superdome systems to HPInteg

Page 21

HA113A1 #588 (installation)configuration, I/O card cageand I/O cards)optional DeploymentManagerI/O cage is field installed(requires installation optio

Page 22

Superdome 16-way to 32-Superdome 16-way to 32-Superdome 16-way to 32-Superdome 16-way to 32-way Upgradeway Upgradeway Upgradeway UpgradeIncludes TCE M

Page 23

Superdome ServiceSuperdome ServiceSuperdome ServiceSuperdome ServiceSolutionsSolutionsSolutionsSolutionsSuperdome continues to provide the same positi

Page 24

TotalTotalTotalTotalAmountAmountAmountAmountMemoryMemoryMemoryMemoryper Cellper Cellper Cellper CellNo. ofNo. ofNo. ofNo. of512 MB512 MB512 MB512 MBNo

Page 25

Superdome SpecificationsSuperdome SpecificationsSuperdome SpecificationsSuperdome SpecificationsSPU Model NumberSPU Model NumberSPU Model NumberSPU Mo

Page 26

3-phase 5-wire input Option 6:3-phase 4-wire input44 A 44 A 44 A Required Power Receptacle-Options 6 and 7None. Cord, plug and included. Receptacle sh

Page 27

Superdome I/O ExpansionSuperdome I/O ExpansionSuperdome I/O ExpansionSuperdome I/O Expansion(IOX) Cabinet(IOX) Cabinet(IOX) Cabinet(IOX) CabinetSpecif

Page 28

G84Y) Units per Pallet1.0 Communications andCommunications andCommunications andCommunications andManagementManagementManagementManagementInterface

Page 29

Superdome Supported I/OSuperdome Supported I/OSuperdome Supported I/OSuperdome Supported I/OCardCardCardCardProduct #Product #Product #Product #HP-UX

Page 30

Superdome Supported Online StorageSuperdome Supported Online StorageSuperdome Supported Online StorageSuperdome Supported Online StorageStorage Device

Page 31

Superdome Supported Nearline StorageSuperdome Supported Nearline StorageSuperdome Supported Nearline StorageSuperdome Supported Nearline StorageStorag

Page 32

© Copyright 2003 Hewlett-Packard Development Company, L.P.The information contained herein is subject to change without notice.Microsoft and Windows S

Page 33

SystemSystemSystemSystemHP UX 11i version 2HP UX 11i version 2HP UX 11i version 2HP UX 11i version 2Windows Server 2003 DatacenterWindows Server 2003

Page 34

There are three basic building blocks in the Superdome system architecture: the cell, the crossbar backplane and the PCI X based I/O subsystem.Cabinet

Page 35

I/O SubsystemI/O SubsystemI/O SubsystemI/O SubsystemEach I/O chassis provides twelve PCI X slots; eight standard and four high bandwidth PCI X slots.

Page 36

I/O Expansion CabinetI/O Expansion CabinetI/O Expansion CabinetI/O Expansion CabinetThe I/O expansion functionality is physically partitioned into fou

Page 37

DVD SolutionDVD SolutionDVD SolutionDVD SolutionThe DVD solution for Superdome requires the following components. These components are recommended per

Page 38

CPUCPUCPUCPU: The features below nearly eliminate the down time associated with CPU cache errors (which are the majorityof CPU errors). If a CPU is ex

Comments to this Manuals

No comments