Specifications 86
Specifications
Environmental specifications
Specification Value
Temperature range*
Operating
10°C to 35°C (50°F to 95°F)
Shipping
-30°C to 50°C (-22°F to 122°F)
Storage
-30°C to 60°C (-22°F to 140°F)
Maximum wet bulb
temperature
28°C (82.4°F)
Relative humidity
(noncondensing)**
Operating
10% to 90%
Non-operating
5% to 95%
* All temperature ratings shown are for sea level. An altitude derating of 1°C per 300 m (1.8°F per 1,000 ft) to 3048
m (10,000 ft) is applicable. No direct sunlight allowed.
** Storage maximum humidity of 95% is based on a maximum temperature of 45°C (113°F). Altitude maximum for
storage corresponds to a pressure minimum of 70 KPa.
Mechanical specifications
Specification Value
Height
8.73 cm (3.44 in)
Depth
74.93 cm (29.50 in)
Width
44.54 cm (17.54 in)
Weight (maximum)
27.66 kg (61.00 lb)
Weight (minimum)
18.59 kg (41.00 lb)
Power supply specifications
The server is configured with the HP 1200 W CS HE Power Supply (94%) ("HP 1200 W CS HE Power Supply
(94%) specifications" on page 86).
HP 1200 W CS HE Power Supply (94%) specifications
Specification Value
Input requirements
Rated input voltage
100 to 120 VAC, 200 to
240 VAC
Rated input frequency
50 Hz to 60 Hz