Hp LeftHand P4000 SAN Solutions User Manual Page 199

  • Download
  • Add to my manuals
  • Print
  • Page
    / 290
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 198
16 Controlling server access to volumes
Application servers (servers), also called clients or hosts, access storage volumes on HP StoreVirtual
Storage using either Fibre Channel or iSCSI connectivity. You set up each server that needs to
connect to volumes in a management group in the CMC. We refer to this setup as a “server
connection.” Server connections can be single servers or server clusters, and can be configured
for both Fibre Channel and iSCSI transport, as long as there is only one server connection to a
volume. Use server clusters in the CMC to assign volumes to the clustered application servers that
are accessing the storage volumes. For example, create two servers and cluster them to assign two
volumes to a Microsoft Exchange cluster or VMware vSphere Server simultaneously.
You can set up iSCSI servers to connect to volumes in three ways. All three ways use the virtual IP
(VIP) for discovery and to log in to the volume from a server’s iSCSI initiator:
iSCSI with VIP and load balancing—Use the load balancing option when you set up a server
connection in the CMC to balance connections to the HP StoreVirtual Storage
Microsoft DSM or HP StoreVirtual DSM for Microsoft MPIO (if using)—Automatically establishes
multiple connections to the HP StoreVirtual Storage
iSCSI with VIP only
Configure Fibre Channel servers using a list of unassigned initiator WWPNs, or you can manually
configure an initiator WWPN.
NOTE: Before setting up a server connection, make sure you are familiar with the Fibre Channel
or iSCSI information in “HP StoreVirtual Storage using iSCSI and Fibre Channel” (page 241).
Setting up server connections to volumes requires the general tasks outlined in Table 65 (page 199).
Table 65 Overview of configuring server access to volumes
For More InformationTask
For iSCSI connectivity, if you are using the HP StoreVirtual
DSM for Microsoft MPIO, ensure that both the Microsoft
Ensure that an iSCSI initiator is installed on the server.
MPIO and the DSM for MPIO are also installed on the
server. Refer to the HP StoreVirtual Storage DSM for MPIO
Deployment Guide
See “Planning iSCSI server connections to management
groups” (page 200) or “Planning Fibre Channel server
connections to management groups” (page 203)
In the CMC, add the server connection to the management
group and configure access for that server.
See “Creating a server cluster” (page 206).Optional: Cluster multiple servers in the CMC to connect
multiple volumes to clustered application servers.
See
Assigning iSCSI server connections access to volumes
(page 208)
In the CMC, assign volumes to the server or server cluster.
or Assigning volumes to Fibre Channel servers” (page 209)
See “Completing the iSCSI Initiator and disk setup
(page 203) or “Completing the Fibre Channel setup”
(page 205)
In the initiator on the server, log on to the volume or LUN.
See “Completing the iSCSI Initiator and disk setup
(page 203) or “Completing the Fibre Channel setup”
(page 205)
On the server, configure the volume or LUN using disk
management tools.
199
Page view 198
1 2 ... 194 195 196 197 198 199 200 201 202 203 204 ... 289 290

Comments to this Manuals

No comments