HP StorageWorks
Brocade 8Gb SAN Switch for
nl
HP BladeSystem c-Class
User Guide
*5697-0960*
Part Number: 5697-0960
First edition: May 2011
Page view 0
1 2 3 4 5 6 ... 63 64

Summary of Contents

Page 1 - HP BladeSystem c-Class

HP StorageWorksBrocade 8Gb SAN Switch fornlHP BladeSystem c-ClassUser Guide*5697-0960*Part Number: 5697-0960First edition: May 2011

Page 2

• Third-party hardware or software• Operating system type and revision levelFor continuous quality improvement, calls may be recorded or monitored.HP

Page 3 - Contents

WARNING!Indicates that failure to follow directions could result in bodily harm or death.CAUTION:Indicates that failure to follow directions could res

Page 4

Documentation feedbackHP welcomes your feedback.To make comments and suggestions about product documentation, please send a message tostoragedocsFeedb

Page 5

1 OverviewThe Brocade 8Gb SAN Switch for HP BladeSystem c-Class (referred to in the rest of this manual asthe 8Gb SAN Switch) is a Fibre Channel (FC)

Page 6

• Hot-swap capability• Compatibility with redundant and dual redundant switch configurations in c-Class BladeSystem• Hot code activation• Real-time cl

Page 7

Figure 2 8Gb SAN Switch external ports.Table 3 Identifying 8Gb SAN Switch external portsDescriptionItem numberLeft bank—ports 17, 18, 19, 201Right ban

Page 8

• Brocade 8/24 SAN Switch for HP BladeSystem c-Class, base, integrating 24 active ports (16 in-ternal and 8 external) and four short-wavelength SFPs.

Page 9 - About this guide

Part numberOptionT5521AHP B-series 8-24 Power Pack+ UpgradeT4269A,nlHP StorageWorks Enterprise Editionv5 Fabric Manager SoftwarenlT4270A,nlFabric Mana

Page 10 - HP contact information

OM3 CableOM2 CableDistance500 meters300 meters2Gb performance860 meters500 meters1Gb performanceOverview18

Page 11 - Other HP websites

2 SetupThis chapter provides the following information:• Shipping carton contents, page 19• Installation and safety considerations, page 20• Install t

Page 12 - Documentation feedback

Legal and notice information© Copyright 2008, 2011 Hewlett-Packard Development Company, L.P.© Copyright 2008, 2011 Brocade Communications Systems, Inc

Page 13 - 1 Overview

Dust covers for empty SFP ports2Brocade 8Gb SAN Switch for HP BladeSystem c-Class installation instructions3Installation and safety considerationsThe

Page 14 - Component identification

1. Locate the appropriate interconnect bay in the rear of the enclosure as specified in the appropriateHP BladeSystem Enclosure Setup and Installation

Page 15 - 8Gb SAN Switch licensing

4. Align the Brocade 8Gb SAN Switch with the appropriate interconnect bay according to yourenclosure’s specific configuration. Push the switch firmly

Page 16 - Supported optional software

Check LEDsSee Figure 6 to locate power-on LEDs. Verify that the LEDs match the indicators described in Table10.Figure 6 Verifying power-on LEDs.Table

Page 17 - Pack+ models

NOTE:Refer to the HP BladeSystem Onboard Administrator user guide for additional information on EBIPA.Using external DHCPTo set the Ethernet IP addres

Page 18 - OM3 CableOM2 CableDistance

9. Identify the interconnect bay number where the switch is installed. At the OA command line,enter:connect interconnect xWhere x is the interconnect

Page 19 - Shipping carton contents

Connect to the Command Line InterfaceMake an Ethernet connection and log in to the 8Gb SAN Switch:1. Connect the workstation to the Ethernet network c

Page 20 - Install the 8Gb SAN Switch

2. Issue the date command using the following syntax:date mmddHHMMyy”where:• mm is the month; valid values are 01 through 12.• dd is the date; valid v

Page 21 - Handle latch2

Enter fabricshow to determine the domain IDs that are currently in use. The maximum number ofdomains with which the 8Gb SAN Switch communicates is det

Page 22 - OA power verification

1. Connect to the switch and log in as admin as described in Connect to the Command LineInterface, page 26.2. Issue portenable portnumber where portnu

Page 23 - Check LEDs

ContentsAbout this guide ... 9Intended audience ...

Page 24 - Using external DHCP

*6 more assignments added if the 2nd POD license is installed4 ports are assigned to installed licenses:4 ports are assigned to the base switch licens

Page 25 - Configure the 8Gb SAN Switch

Backing up the configurationTo back up the switch configuration to an FTP server, enter configupload and follow the prompts.The configupload command c

Page 27 - Verifying installed licenses

3 Managing the 8Gb SAN SwitchThis chapter provides the following information:• Management features, page 33• Maintaining the 8Gb SAN Switch, page 34•

Page 28 - Disabling and enabling a port

The gateway address of the first switch should be set to whatever the gateway address is for thesubnet on which the first switch resides. See Table 12

Page 29 - DPOD commands

2. Orient the SFP with the appropriate port. See Figure 7 and Table 13.Figure 7 Installing an SFP.Table 13 SFP componentsDescriptionItembail1SFP23. In

Page 30 - Verifying the configuration

Powering on and off8Gb SAN Switch power is provided by the enclosure. The 8Gb SAN Switch runs POST by defaulteach time power to the enclosure is turne

Page 31 - Backing up the configuration

LED patternsTable 15 and Table 16 summarize LED color, and meaning, as well as any recommended userresponse.Module status LED patternsThe system and p

Page 32

Recommended actionStatus of hardwareLED colorLED nameEnable the port using the portEnable com-mand; If the LEDs for all ports are slow-flashingamber,

Page 33 - 3 Managing the 8Gb SAN Switch

Interpreting POST resultsTo determine whether POST completed successfully and whether any errors were detected:1. Verify that the 8Gb SAN Switch LEDs

Page 34 - Replacing an SFP transceiver

Using Dynamic Ports On Demand (DPOD) ... 29DPOD commands ...

Page 35 - Diagnostic tests

About the reset buttonThe Brocade 8Gb SAN Switch integrates a Reset button, (Figure 9). The Reset button is a small,recessed micro-switch that is acce

Page 36 - Interpreting LED activity

1. Create a backup of the existing configuration file.NOTE:It is critical to back up the switch configuration to a remote server on a regular basis. R

Page 37 - LED patterns

IMPORTANT:HP recommends upgrading all switches in the enclosure to the latest available firmware. Checkhttp://www.hp.com for updates.Managing the 8Gb

Page 38 - POST and boot specifications

A Regulatory compliance and safetyRegulatory complianceFederal Communications Commission notice for Class A equipmentThis equipment has been tested an

Page 39 - Firmware update

WARNING!Use of controls or adjustments or performance of procedures other than those specified herein or inthe laser product’s installation guide may

Page 40 - About the reset button

Cet appareil numérique de la classe A respecte toutes les exigences du Règlement sur le matérielbrouilleur du Canada.European union regulatory noticeB

Page 41 - Fabric OS command reference

Korean noticeSafetyBattery replacement noticeYour switch is equipped with a lithium manganese dioxide, a vanadium pentoxide, or an alkalineinternal ba

Page 42 - IMPORTANT:

Taiwan battery recycling noticeThe Taiwan EPA requires dry battery manufacturing or importing firms in accordance with Article 15of the Waste Disposal

Page 43 - Regulatory compliance

Regulatory compliance and safety48

Page 44 - Class A equipment

B Electrostatic dischargeThis appendix provides the following information:• How to prevent electrostatic discharge, page 49• Grounding methods, page 4

Page 45 - Japanese notice

General specifications ... 51Weight and ph

Page 46 - Battery replacement notice

Electrostatic discharge50

Page 47 - Japanese power cord statement

C SAN Switch technical specificationsThis appendix provides the following information:• General specifications, page 51• Weight and physical dimension

Page 48

DescriptionSpecification• IEC 61000-4-2 Severity Level 3 for Electrostatic Discharge• IEC 61000-4-3 Severity Level 3 for Radiated Fields• IEC 61000-4-

Page 49 - B Electrostatic discharge

Environmental requirementsTo ensure proper operation, the switch must not be subjected to environmental conditions beyondthose for which it was tested

Page 50 - Electrostatic discharge50

SAN Switch technical specifications54

Page 51 - General specifications

GlossaryThis glossary defines terms used in this guide or related to this product. It is not a comprehensiveglossary of computer terms.AL_PA Arbitrate

Page 52 - MeasurementDimension

data word A type of transmission word that occurs within frames. The frame header, datafield, and CRC all consist of data words.defined zoneconfigurat

Page 53 - Supported HBAs

FCS switch Fabric Configuration Server switch. One or more designated HP switches thatstore and manage the configuration and security parameters for a

Page 54

K28.5 A special 10-bit character that indicates the beginning of a transmission wordthat performs FC control and signaling functions. The first seven

Page 55 - Glossary

multicast The transmission of data from a single source to multiple specified N_Ports (asopposed to all ports on the network).N_Port Node port. A port

Page 56 - Glossary56

FiguresBrocade 8Gb SAN Switch components ... 1418Gb SAN Switch external ports ...

Page 57

private loop An arbitrated loop that does not include a participating FL_Port.private NL_Port An NL_Port that communicates only with other private NL_

Page 58 - Glossary58

SNS Simple Name Server. A switch service that stores names, addresses, and attributesfor up to 15 minutes, and provides them as required to other devi

Page 59

Glossary62

Page 60 - Glossary60

IndexAadvanced web tools, 33advanced zoning, 17audience, 9Bboot, 38boot specifications, 38Ccommand line interface, 33conventionsdocument, 10text symbo

Page 61

SSAN Switchconfiguration, 25installing, 20licensing, 15maintenance, 34management features, 33port diagram, 14power, 36SFP transceiver, 25removing, 34S

Page 62 - Glossary62

TablesDocument conventions ... 101Brocade 8Gb SAN Switch com

Page 64

About this guideThis guide provides information about setting up and configuring the Brocade 8Gb SAN Switch forHP BladeSystem c-Class. Throughout this