53-1003108-0112 December 2013®Fabric OSCommand ReferenceSupporting Fabric OS v7.2.1
x Fabric OS Command Reference53-1003108-01dnsConfig . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
72 Fabric OS Command Reference53-1003108-01bladeDisable2bladeDisableDisables all user ports on a blade. SYNOPSIS bladedisable slotDESCRIPTION Use this
972 Fabric OS Command Reference53-1003108-01secHelp2secHelpDisplays information about security commands. SYNOPSIS sechelpDESCRIPTION Use this command
Fabric OS Command Reference 97353-1003108-01secPolicyAbort2secPolicyAbortAborts all unsaved changes to the defined database. SYNOPSIS secpolicyabortDE
974 Fabric OS Command Reference53-1003108-01secPolicyActivate2secPolicyActivateSaves and activates the Defined Security Policy Set. SYNOPSIS secpolicy
Fabric OS Command Reference 97553-1003108-01secPolicyAdd2secPolicyAddAdds members to an existing security policy. SYNOPSIS secpolicyadd "name&quo
976 Fabric OS Command Reference53-1003108-01secPolicyAdd2OPERANDS This command has the following operands:"name"Specify the name of an exist
Fabric OS Command Reference 97753-1003108-01secPolicyAdd2To add two devices to attach to domain 3, ports 1 and 3, in an existing empty DCC policy; the
978 Fabric OS Command Reference53-1003108-01secPolicyCreate2secPolicyCreateCreates a new security policy. SYNOPSIS secpolicycreate "name" [,
Fabric OS Command Reference 97953-1003108-01secPolicyCreate2The specified policy name must be capitalized.The DCC_POLICY_nnn name has the common prefi
980 Fabric OS Command Reference53-1003108-01secPolicyCreate2EXAMPLES To create an FCS policy (While creating the FCS policy, the local switch WWN is a
Fabric OS Command Reference 98153-1003108-01secPolicyCreate2_______________________________________ DEFINED POLICY SETSCC_POLICY WWN
Fabric OS Command Reference 7353-1003108-01bladeDisable2385 5 1 ------ cu 8G In_Sync FC Disabled386 5 2 ------ cu 8G
982 Fabric OS Command Reference53-1003108-01secPolicyDelete2secPolicyDeleteDeletes an existing security policy. SYNOPSIS secpolicydelete nameDESCRIPTI
Fabric OS Command Reference 98353-1003108-01secPolicyDelete2To delete all stale DCC policies in the fabric: primaryfcs:admin> secpolicydelete ALL_S
984 Fabric OS Command Reference53-1003108-01secPolicyDump2secPolicyDumpDisplays the members of one or all existing security policies. SYNOPSIS secpoli
Fabric OS Command Reference 98553-1003108-01secPolicyDump2To display all security policies in the active database:switch:admin> secpolicydump "
986 Fabric OS Command Reference53-1003108-01secPolicyDump2To display the SCC policies in the defined database:switch:admin> secpolicydump "Def
Fabric OS Command Reference 98753-1003108-01secPolicyFCSMove2secPolicyFCSMoveMoves a member in the FCS policy. SYNOPSIS secpolicyfcsmove [from, to]DES
988 Fabric OS Command Reference53-1003108-01secPolicyFCSMove23 No 10:00:00:05:1e:35:cd:ef 200 switch3switch:admin> secpolicyfcsmove 3,1_____
Fabric OS Command Reference 98953-1003108-01secPolicyRemove2secPolicyRemoveRemoves members from an existing security policy. SYNOPSIS secpolicyremove
990 Fabric OS Command Reference53-1003108-01secPolicyRemove2(*)Selects all ports on the switch.[3, 9]Selects ports 3 and 9 and all devices attached to
Fabric OS Command Reference 99153-1003108-01secPolicySave2secPolicySaveSaves a defined security policy to persistent memory. SYNOPSIS secpolicysaveDES
74 Fabric OS Command Reference53-1003108-01bladeEnable2bladeEnableEnables all user ports on a blade. SYNOPSIS bladeenable slotDESCRIPTION Use this com
992 Fabric OS Command Reference53-1003108-01secPolicyShow2secPolicyShowDisplays an existing security policy including the FCS policy. SYNOPSIS secpoli
Fabric OS Command Reference 99353-1003108-01secPolicyShow2To display all security policies from defined databases: switch:admin> secpolicyshow &quo
994 Fabric OS Command Reference53-1003108-01secStatsReset2secStatsResetResets one or all security statistics to 0. SYNOPSIS secstatsreset [name][,&quo
Fabric OS Command Reference 99553-1003108-01secStatsReset2To reset DCC_POLICY statistics on domains 1 and 69:primaryfcs:admin> secstatsreset DCC_PO
996 Fabric OS Command Reference53-1003108-01secStatsShow2secStatsShowDisplays one or all security statistics. SYNOPSIS secstatsshow [name[,"domai
Fabric OS Command Reference 99753-1003108-01secStatsShow2EXAMPLES To display the LOGIN policy statistics for the local domain. switch:admin> secsta
998 Fabric OS Command Reference53-1003108-01sensorShow2sensorShowDisplays sensor readings. SYNOPSIS sensorshowDESCRIPTION Use this command to display
Fabric OS Command Reference 99953-1003108-01serDesTuneMode2serDesTuneModeConfigures and displays SerDes tuning values. SYNOPSIS serdestunemode --setse
1000 Fabric OS Command Reference53-1003108-01serDesTuneMode2--resetDisables SerDes tuning mode and resets SerDes values to default on FC8-16 blades in
Fabric OS Command Reference 100153-1003108-01serDesTuneMode2To disable SerDes tuning optimization on all backend ports and reset all tuning values to
Fabric OS Command Reference 7553-1003108-01bladeEnable2 3 UNKNOWN VACANT 4 SW BLADE 2 ENABLED 5 CP BLADE 1 ENAB
1002 Fabric OS Command Reference53-1003108-01setContext2setContextSets the logical switch context to a specified FID. SYNOPSIS setcontext [FID | switc
Fabric OS Command Reference 100353-1003108-01setDbg2setDbgSets the debug level of the specified module. SYNOPSIS setdbg [module_name][level]DESCRIPTIO
1004 Fabric OS Command Reference53-1003108-01setVerbose2setVerboseSpecifies module verbose level. SYNOPSIS setverbose [module_name][level]DESCRIPTION
Fabric OS Command Reference 100553-1003108-01sfpShow2sfpShowDisplays Small Form-factor Pluggable (SFP) transceiver information. SYNOPSIS sfpshowsfpsho
1006 Fabric OS Command Reference53-1003108-01sfpShow2-fRefreshes the SFP information. This option is valid only when sfpShow is issued for a specific
Fabric OS Command Reference 100753-1003108-01sfpShow2Slot 2/Port 9: idSlot 2/Port 10: idSlot 2/Port 11: idSlot 2/Port 12: idSlot 2/Port 13: idSl
1008 Fabric OS Command Reference53-1003108-01sfpShow2RX Power: -4.0 dBm (402.0uW) 10.0 uW 1258.9 uW 15.8 uW 1000.0 uWTX Power: -3.1
Fabric OS Command Reference 100953-1003108-01sfpShow2Connector: 12 MPO Parallel OpticTransceiver: 0000000000000000 16_Gbps idEncoding: 5 64
1010 Fabric OS Command Reference53-1003108-01sfpShow2Length 50u: 5 (units 10 meters)Length 62.5u:3 (units 10 meters)Length Cu: 0 (units 1
Fabric OS Command Reference 101153-1003108-01sfpShow2To display detailed information about a QSFP:switch:admin> sfpshow 8/0QSFP No: 0 Channel No:0I
76 Fabric OS Command Reference53-1003108-01bladeSwap2bladeSwapSwaps the area numbers for matching port pairs of two blades. SYNOPSIS bladeSwap -src so
1012 Fabric OS Command Reference53-1003108-01shellFlowControlDisable2shellFlowControlDisableDisables XON/XOFF flow control on the console serial port.
Fabric OS Command Reference 101353-1003108-01shellFlowControlEnable2shellFlowControlEnableEnables XON/XOFF flow control on the console serial port. SY
1014 Fabric OS Command Reference53-1003108-01slotPowerOff2slotPowerOffRemoves power from a slot. SYNOPSIS slotpoweroff slotDESCRIPTION Use this comman
Fabric OS Command Reference 101553-1003108-01slotPowerOn2slotPowerOnRestores power to a slot. SYNOPSIS slotpoweron slotDESCRIPTION Use this command to
1016 Fabric OS Command Reference53-1003108-01slotShow2slotShowDisplays the status of all slots in the system. SYNOPSIS slotshow [-m] [-p]DESCRIPTION U
Fabric OS Command Reference 101753-1003108-01slotShow246 CR4S-8 core blade50CP8 control processor blade51FC8-48 switch blade52Core8 core blade55FC8-32
1018 Fabric OS Command Reference53-1003108-01slotShow2DISABLEDThe blade is powered on but disabled.FAULTYThe blade is faulty because an error was dete
Fabric OS Command Reference 101953-1003108-01slotShow2To display the Brocade model name for each blade on a Brocade DCX 8510-8:switch:user> slotsho
1020 Fabric OS Command Reference53-1003108-01slotShow2To display power consumption information on a Brocade DCX 8510-4:switch:user> slotshow -pSlot
Fabric OS Command Reference 102153-1003108-01snmpConfig2snmpConfigManages the SNMP agent configuration. SYNOPSIS snmpConfig --show | --set | --default
Fabric OS Command Reference 7753-1003108-01bootLunCfg2bootLunCfgTransparently configures the boot LUN for an HBA. SYNOPSIS bootluncfg --add HBA_WWN PW
1022 Fabric OS Command Reference53-1003108-01snmpConfig2--setSets the SNMP agent configuration data of the specified category. This operand displays t
Fabric OS Command Reference 102353-1003108-01snmpConfig2SNMPv1 Configuration Parameters The agent supports six communities and their associated trap r
1024 Fabric OS Command Reference53-1003108-01snmpConfig2• User 5: snmpuser2• User 6: snmpuser3The --default option sets the user name and password to
Fabric OS Command Reference 102553-1003108-01snmpConfig2 swDeviceStatusTrap (16) Disabled swZoneConfigChangeTrap (17)
1026 Fabric OS Command Reference53-1003108-01snmpConfig2The following MIB configuration options are supported:--set mibCapabilityConfigures MIBs inter
Fabric OS Command Reference 102753-1003108-01snmpConfig2System Group Configuration Parameters sysDescrThe system description. The default value is Fib
1028 Fabric OS Command Reference53-1003108-01snmpConfig2To set the SNMPv1 configuration of a switch:switch:admin> snmpConfig --set snmpv1SNMP commu
Fabric OS Command Reference 102953-1003108-01snmpConfig2 -warning 4- informational 0 -None): 4 swFabricWatchTrap (yes, y, no, n): [yes] Desired
1030 Fabric OS Command Reference53-1003108-01snmpConfig2 swExtTrap: NO swStateChangeTrap: NO swPortMoveTrap: NO swBrcdGene
Fabric OS Command Reference 103153-1003108-01snmpConfig2 swPortMoveTrap: NO swBrcdGenericTrap: NO swDeviceStatusTrap: NO s
78 Fabric OS Command Reference53-1003108-01bootLunCfg2EXAMPLES To configure a boot LUN:switch:admin> bootluncfg --add 11:22:ab:44:44:ff:44:ca \
1032 Fabric OS Command Reference53-1003108-01snmpConfig2To set the security level:switch:admin> snmpconfig --set seclevelSelect SNMP Security Level
Fabric OS Command Reference 103353-1003108-01snmpConfig2To enable inform requests to be sent instead of trap requests:switch:admin> snmpconfig --se
1034 Fabric OS Command Reference53-1003108-01snmpConfig2REFERENCES Refer to the following publications for further information on SNMP:• SW_v5_x.mib,
Fabric OS Command Reference 103553-1003108-01snmpTraps2snmpTrapsSends or displays SNMP traps. SYNOPSIS snmptraps --send [-trap_name trap_name] [-
1036 Fabric OS Command Reference53-1003108-01snmpTraps2--helpDisplays the command usage.EXAMPLES To send all traps to the configured recipients:switch
Fabric OS Command Reference 103753-1003108-01snmpTraps2To block a single port from receiving traps:switch:admin> snmpTraps --block 17To unblock a p
1038 Fabric OS Command Reference53-1003108-01spinFab2spinFabRuns functional test of interswitch link (ISL) cabling and trunk group operation. SYNOPSIS
Fabric OS Command Reference 103953-1003108-01spinFab2• Long Distance ports• F_Ports connected to an HBAThe following ports do not support the spinFab
1040 Fabric OS Command Reference53-1003108-01spinFab2-fports flagInstructs spinFab to include or exclude F_Ports in the testing. This feature is disab
Fabric OS Command Reference 104153-1003108-01spinFab2PORT_ENABLEPORT_M2MPORT_STOPPEDPORT_WRONGRXQ_RAM_PERRSTATSSTATS_C3FRXSTATS_FRXSTATS_FTXTIMEOUTXMI
Fabric OS Command Reference 7953-1003108-01bottleneckMon2bottleneckMonMonitors and reports latency and congestion bottlenecks on F_Ports and E_Ports.
1042 Fabric OS Command Reference53-1003108-01sshUtil2sshUtilManages public key authentication. SYNOPSIS sshutil allowuser user namesshutil showuserssh
Fabric OS Command Reference 104353-1003108-01sshUtil2This command supports generation of a public/private key pair on the switch to enable outgoing co
1044 Fabric OS Command Reference53-1003108-01sshUtil2delpubkeyDeletes all imported public keys associated with a specified user on the switch or with
Fabric OS Command Reference 104553-1003108-01sshUtil2To set up SSH public key authentication on a switch for incoming connections:1. Generate a privat
1046 Fabric OS Command Reference53-1003108-01sshUtil2To set up SSH public key authentication on a switch for outgoing connections:1. Generate a privat
Fabric OS Command Reference 104753-1003108-01statsClear2statsClearClears port and diagnostic statistics. SYNOPSIS statsclear [--slot slot] [-u
1048 Fabric OS Command Reference53-1003108-01stopPortTest2stopPortTestTerminates the running portTest.SYNOPSIS stopporttest [-ports itemlist]DESCRIPTI
Fabric OS Command Reference 104953-1003108-01supportFfdc2supportFfdcModifies or displays the first-fault data capture (FFDC) daemon. SYNOPSIS supportf
1050 Fabric OS Command Reference53-1003108-01supportFtp2supportFtpSets, clears, or displays support FTP parameters and enables or disables auto file t
Fabric OS Command Reference 105153-1003108-01supportFtp2-R Clears all supportFtp parameters.-eEnables auto file transfer. Trace dump files are automat
80 Fabric OS Command Reference53-1003108-01bottleneckMon2• Configuring severity thresholds for congestion and latency bottlenecks for a switch or for
1052 Fabric OS Command Reference53-1003108-01supportSave2supportSaveSaves RASLOG, TRACE, supportShow, core file, FFDC data, and other support informat
Fabric OS Command Reference 105353-1003108-01supportSave2-cUses the FTP, SCP, or SFTP parameters saved by the supportFtp command. This operand is opti
1054 Fabric OS Command Reference53-1003108-01supportSave2EXAMPLES To save RASLOG, TRACE, supportShow, and other support information to an FTP server i
Fabric OS Command Reference 105553-1003108-01supportSave2Saving support information for chassis:ras9,module:RTE...Saving support information for chass
1056 Fabric OS Command Reference53-1003108-01supportShow2supportShowDisplays switch information for debugging purposes. SYNOPSIS supportshowsupportsho
Fabric OS Command Reference 105753-1003108-01supportShow2fcipFCIP group commands, disabled by default.agAccess Gateway group commands, disabled by def
1058 Fabric OS Command Reference53-1003108-01supportShow2 security enabled network enabled portlog enabled system enabled extend disab
Fabric OS Command Reference 105953-1003108-01supportShowCfgDisable2supportShowCfgDisableDisables a group of commands under the supportShow command.SYN
1060 Fabric OS Command Reference53-1003108-01supportShowCfgDisable2asic_dbDisables the ASIC DB group commands.agDisables the Access Gateway group comm
Fabric OS Command Reference 106153-1003108-01supportShowCfgEnable2supportShowCfgEnableEnables a group of commands to be displayed under the supportSho
Fabric OS Command Reference 8153-1003108-01bottleneckMon2severity on the switch. You can filter the output to display only latency or congestion bottl
1062 Fabric OS Command Reference53-1003108-01supportShowCfgEnable2asic_dbEnables the ASIC DB group commands.agEnables the Access Gateway group command
Fabric OS Command Reference 106353-1003108-01supportShowCfgShow2supportShowCfgShowDisplays the groups of commands enabled for display by the supportSh
1064 Fabric OS Command Reference53-1003108-01supportShowCfgShow2 iswitch enabled asic_db enabled fcip enabled ag enabled dce_hsl
Fabric OS Command Reference 106553-1003108-01switchBeacon2switchBeaconSets switch beaconing mode on or off. SYNOPSIS switchbeacon [mode]DESCRIPTION Us
1066 Fabric OS Command Reference53-1003108-01switchBeacon2To turn beaconing mode off to verify the configuration::switch:admin> switchbeacon 0switc
Fabric OS Command Reference 106753-1003108-01switchCfgPersistentDisable2switchCfgPersistentDisableDisables a switch persistently.SYNOPSIS switchcfgper
1068 Fabric OS Command Reference53-1003108-01switchCfgPersistentEnable2switchCfgPersistentEnableEnables a switch persistently. SYNOPSIS switchcfgpersi
Fabric OS Command Reference 106953-1003108-01switchCfgSpeed2switchCfgSpeedConfigures the speed for all ports on a switch. SYNOPSIS switchcfgspeed spee
1070 Fabric OS Command Reference53-1003108-01switchCfgTrunk2switchCfgTrunkEnables or disables trunking on all the ports of a switch. SYNOPSIS switchcf
Fabric OS Command Reference 107153-1003108-01switchDisable2switchDisableDisables all user ports on a switch. SYNOPSIS switchdisableDESCRIPTION Use thi
Fabric OS Command Reference xi53-1003108-01fcrEdgeShow . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
82 Fabric OS Command Reference53-1003108-01bottleneckMon2Per-port overrides for alert parametersCustom configuration for the above mentioned alert par
1072 Fabric OS Command Reference53-1003108-01switchEnable2switchEnableEnables all user ports on a switch. SYNOPSIS switchenableDESCRIPTION Use this co
Fabric OS Command Reference 107353-1003108-01switchName2switchNameDisplays or sets the switch name. SYNOPSIS switchname [name]DESCRIPTION Use this com
1074 Fabric OS Command Reference53-1003108-01switchShow2switchShowDisplays switch and port status. SYNOPSIS switchshowswitchshow [-slot slot] [-portna
Fabric OS Command Reference 107553-1003108-01switchShow2LS AttributesOn a switch in Virtual Fabric mode, this field displays logical switch attributes
1076 Fabric OS Command Reference53-1003108-01switchShow210G10 Gbps fixed transfer speedN1010 Gbps negotiated transfer speed16G16 Gbps fixed transfer s
Fabric OS Command Reference 107753-1003108-01switchShow2OnlineThe port is up and running.ProtoProtocol support by GbE port. Valid protocols include th
1078 Fabric OS Command Reference53-1003108-01switchShow2G_PortPoint-to-point port, but not yet E_Port or F_Port.L_PortLoop port; displays the number o
Fabric OS Command Reference 107953-1003108-01switchShow2(logical)Indicates a logical port. The switchShow output shows all logical ports currently pre
1080 Fabric OS Command Reference53-1003108-01switchShow2OPERANDS This command has the following operands:-slot slotDisplays blade information. You can
Fabric OS Command Reference 108153-1003108-01switchShow2 19 19 -- N8 No_Module FC 20 20 -- N8 No_Module FC 21 21 -- N8
Fabric OS Command Reference 8353-1003108-01bottleneckMon2OPERANDS Bottleneck detection commands The following operands support bottleneck detection:sl
1082 Fabric OS Command Reference53-1003108-01switchShow2To display switch configuration information on the Brocade FCoE10-24:switch:admin> switchsh
Fabric OS Command Reference 108353-1003108-01switchShow2Slot Blade Type ID Status -------------------------------------------------5
1084 Fabric OS Command Reference53-1003108-01switchShow2406 5 22 13 ------ -- 16G No_Module FC407 5 23 13 ------ --
Fabric OS Command Reference 108553-1003108-01switchShow2431 8 15 14 ------ -- 16G No_Module FC432 8 16 13 ------ --
1086 Fabric OS Command Reference53-1003108-01switchShow2To display media type information (relevant output excerpts only):• The following example show
Fabric OS Command Reference 108753-1003108-01switchShow2To display the output when any of the ICL links get disabled with no Enterprise ICL (EICL) lic
1088 Fabric OS Command Reference53-1003108-01switchShow2switchRole: PrincipalswitchDomain: 1switchId: fffc01switchWwn: 10:00:00:05:1e:48:
Fabric OS Command Reference 108953-1003108-01switchStatusPolicySet2switchStatusPolicySetSets the policy parameters that determine the overall switch s
1090 Fabric OS Command Reference53-1003108-01switchStatusPolicySet2ErrorPortsPercentage of ports segmented and disabled due to security violations or
Fabric OS Command Reference 109153-1003108-01switchStatusPolicySet2To change the switch policy parameters on a Brocade DCX 8510-8:switch:admin> swi
84 Fabric OS Command Reference53-1003108-01bottleneckMon2When you specify one of the three alert options, the following parameters become available, a
1092 Fabric OS Command Reference53-1003108-01switchStatusPolicyShow2switchStatusPolicyShowDisplays the policy parameters that determine the overall sw
Fabric OS Command Reference 109353-1003108-01switchStatusShow2switchStatusShowDisplays overall switch status. SYNOPSIS switchstatusshowDESCRIPTION Use
1094 Fabric OS Command Reference53-1003108-01switchStatusShow2 Fans monitor HEALTHY Flash monitor MARGINAL Marginal ports moni
Fabric OS Command Reference 109553-1003108-01switchUptime2switchUptimeDisplays the amount of time the switch has been operating. SYNOPSIS switchuptime
1096 Fabric OS Command Reference53-1003108-01switchViolation2switchViolationDumps the DCC violations for a switch. SYNOPSIS switchViolation --dump -dc
Fabric OS Command Reference 109753-1003108-01syslogdFacility2syslogdFacilitySets or displays the syslog facility. SYNOPSIS syslogdFacility [-l level]D
1098 Fabric OS Command Reference53-1003108-01syslogdIpAdd2syslogdIpAddConfigures a switch to forward system messages to specified servers. SYNOPSIS sy
Fabric OS Command Reference 109953-1003108-01syslogdIpRemove2syslogdIpRemoveRemoves a server that is running the syslog daemon. SYNOPSIS syslogdipremo
1100 Fabric OS Command Reference53-1003108-01syslogdIpShow2syslogdIpShowDisplays all syslog daemon IP addresses. SYNOPSIS syslogdipshowDESCRIPTION Dis
Fabric OS Command Reference 110153-1003108-01sysMonitor2sysMonitorConfigures Fabric Watch thresholds for environment and system resources. SYNOPSIS sy
Fabric OS Command Reference 8553-1003108-01bottleneckMon2--exclude [slot/]port_listExcludes the specified ports from bottleneck detection. No data wil
1102 Fabric OS Command Reference53-1003108-01sysMonitor2If any configured area exceeds the currently effective threshold settings, the Fabric Watch da
Fabric OS Command Reference 110353-1003108-01sysMonitor2-action actionsSpecifies the actions triggered by a configured event condition. Valid values i
1104 Fabric OS Command Reference53-1003108-01sysMonitor2-currentDisplays current values for a specified class or area. This operand is optional and va
Fabric OS Command Reference 110553-1003108-01sysMonitor2--show cpu | mem Displays system memory or CPU usage.--helpDisplays the command usage.EXAMPLES
1106 Fabric OS Command Reference53-1003108-01sysMonitor2 Buffer: Custom: Value : 10 Default: Value : 10To
Fabric OS Command Reference 110753-1003108-01sysMonitor2To pause monitoring of the resources class for a single element:switch:admin> sysmonitor --
1108 Fabric OS Command Reference53-1003108-01sysShutDown2sysShutDownProvides a graceful shutdown to protect the switch file systems. SYNOPSIS sysshutd
Fabric OS Command Reference 110953-1003108-01sysShutDown2To attempt a system shutdown from the standby CP (not supported):switch:admin> sysshutdown
1110 Fabric OS Command Reference53-1003108-01tempShow2tempShowDisplays temperature readings. SYNOPSIS tempshowDESCRIPTION Use this command to display
Fabric OS Command Reference 111153-1003108-01thConfig2thConfigConfigures Fabric Watch thresholds for the SFP, fabric, filter, security and EE monitor
86 Fabric OS Command Reference53-1003108-01bottleneckMon2-refreshRefreshes the display to continuously update with fresh data at a certain rate. The r
1112 Fabric OS Command Reference53-1003108-01thConfig2NOTES Monitoring of Condor 3-based 10G SFPs, 16G SFPs, and 16G QSFPs (quad small form-factor plu
Fabric OS Command Reference 111353-1003108-01thConfig2FC Tracks the number of times the fabric reconfigures.DC Tracks the number of Domain ID changes.
1114 Fabric OS Command Reference53-1003108-01thConfig2EEMonitors the End-to-End Performance Monitor class. Valid areas for the EE class include the fo
Fabric OS Command Reference 111553-1003108-01thConfig2-lowth -value valueSpecifies the low threshold for triggering a specified alert action. To chang
1116 Fabric OS Command Reference53-1003108-01thConfig2--showDisplays the threshold configuration or run-time status for all configured classes and are
Fabric OS Command Reference 111753-1003108-01thConfig2EXAMPLES To set custom thresholds for the SFP class and temperature area for a 16G QSFP on a DC
1118 Fabric OS Command Reference53-1003108-01thConfig2 Buffer: Custom: Value : 0 Default
Fabric OS Command Reference 111953-1003108-01thConfig2SFP |TEMP |001152|0 |Info |Continue |QSFPSFP |TEMP |001157|0 |Inf
1120 Fabric OS Command Reference53-1003108-01thMonitor2thMonitorEnables monitoring of small form-factor pluggables (SFPs). SYNOPSIS thmonitor --enable
Fabric OS Command Reference 112153-1003108-01timeOut2timeOutSets or displays the idle timeout value for a login session. SYNOPSIS timeout [timeval]DES
Fabric OS Command Reference 8753-1003108-01bottleneckMon2VCSpecifies the Virtual Channel number. The valid range is 1 trough 31. VC 0 is invalid.--lin
1122 Fabric OS Command Reference53-1003108-01topologyShow2topologyShowDisplays the unicast fabric topology. SYNOPSIS topologyshow [domain]DESCRIPTION
Fabric OS Command Reference 112353-1003108-01topologyShow2Total BandwidthThe maximum bandwidth of the out port. A bandwidth that is less than 0.512 Gb
1124 Fabric OS Command Reference53-1003108-01topologyShow2Name: fcr_xd_3_5Path Count: 1 Hops: 2 Out Port:
Fabric OS Command Reference 112553-1003108-01traceDump2traceDumpInitiates, or removes a trace dump or displays the trace dump status. SYNOPSIS tracedu
1126 Fabric OS Command Reference53-1003108-01traceDump2-rClears the status of a particular trace dump on a specified slot.-RClears the status of a par
Fabric OS Command Reference 112753-1003108-01trunkDebug2trunkDebugDebugs a trunk link failure. SYNOPSIS trunkdebug port1 port2DESCRIPTION Use this com
1128 Fabric OS Command Reference53-1003108-01trunkShow2trunkShowDisplays trunking information. SYNOPSIS trunkshow [-perf]DESCRIPTION Use this command
Fabric OS Command Reference 112953-1003108-01trunkShow2NOTES The execution of this command is subject to Virtual Fabric or Admin Domain restrictions t
1130 Fabric OS Command Reference53-1003108-01trunkShow2 52 4 4 013400 id N4 Online EX-Port \ (Trunk port, master is Slot 4 Port 1 ) 53 4 5
Fabric OS Command Reference 113153-1003108-01tsClockServer2tsClockServerDisplays or sets the Network Time Protocol (NTP) Server addresses. SYNOPSIS ts
88 Fabric OS Command Reference53-1003108-01bottleneckMon2To change the bottleneck detection configuration on port 5 to allow congestion alerts only; o
1132 Fabric OS Command Reference53-1003108-01tsClockServer2To set the NTP server to a specified IP address:switch:admin> tsclockserver 123.123.123.
Fabric OS Command Reference 113353-1003108-01tsTimeZone2tsTimeZoneDisplays or sets the system time zone. SYNOPSIS tstimezone --interactivetstimezone t
1134 Fabric OS Command Reference53-1003108-01tsTimeZone2hourOffsetSpecifies the number of hours relative to GMT. This operand must be specified as an
Fabric OS Command Reference 113553-1003108-01tsTimeZone213) Chile 40) St Barthelemy14) Colombia 41) St
1136 Fabric OS Command Reference53-1003108-01tsTimeZone2Is the above information OK?1) Yes2) NoEnter number or control-D to quit ?1System Time Zone ch
Fabric OS Command Reference 113753-1003108-01turboRamTest2turboRamTestPerforms a turbo SRAM test of ASIC chips. SYNOPSIS turboramtest [--slot slot
1138 Fabric OS Command Reference53-1003108-01turboRamTest2To run the SRAM test on a Brocade FCoE10-24 blade in default mode:switch:admin> ceeturbor
Fabric OS Command Reference 113953-1003108-01upTime2upTimeDisplays length of time the system has been operational. SYNOPSIS uptimeDESCRIPTION This com
1140 Fabric OS Command Reference53-1003108-01uRouteShow2uRouteShowDisplays unicast routing information. SYNOPSIS urouteshow [slot/][port] [domain]DESC
Fabric OS Command Reference 114153-1003108-01uRouteShow2NOTES The execution of this command is subject to Virtual Fabric or Admin Domain restrictions
Fabric OS Command Reference 8953-1003108-01bottleneckMon2Feb 26 21:56:10 Feb 26 21:56:20 0Feb 26 21:56:00 Feb 26 21:56:10 0Feb 2
1142 Fabric OS Command Reference53-1003108-01usbStorage2usbStorageManages data files on an attached USB storage device. SYNOPSIS usbstorage [-e | --en
Fabric OS Command Reference 114353-1003108-01usbStorage2To list the contents of the attached USB device:switch:admin> usbstorage -lfirmwarekey\
1144 Fabric OS Command Reference53-1003108-01userConfig2userConfigManages user accounts. SYNOPSIS userconfiguserconfig --show [username | -a | -r role
Fabric OS Command Reference 114553-1003108-01userConfig2Use the distribute command to distribute the account database manually to other switches in th
1146 Fabric OS Command Reference53-1003108-01userConfig2-cDisplays a list of users who have permission to execute chassis commands.--add | --changeCre
Fabric OS Command Reference 114753-1003108-01userConfig2-a AD_ID_listSpecifies the Administrative Domains the user is authorized to access. The Admin
1148 Fabric OS Command Reference53-1003108-01userConfig2-h AD_IDSpecifies the account's home Admin Domain. This operand is optional.• If a home A
Fabric OS Command Reference 114953-1003108-01userConfig2-c [chassis_role]Specifies the account's access permissions regarding chassis-level comma
1150 Fabric OS Command Reference53-1003108-01userConfig2To add an account named bob with role ZoneAdmin and Admin Domain member list 1,4,10,11,12,13,1
Fabric OS Command Reference 115153-1003108-01userConfig2To display the test account information:switch:admin> userconfig --show testAccount name: t
90 Fabric OS Command Reference53-1003108-01bottleneckMon2Jan 13 18:54:10 Jan 13 18:54:15 20.00Jan 13 18:54:15 Jan 13 18:54:20
1152 Fabric OS Command Reference53-1003108-01version2versionDisplays firmware version information. SYNOPSIS versionDESCRIPTION Use this command to dis
Fabric OS Command Reference 115353-1003108-01wwn2wwnDisplays the world wide name (WWN) and factory serial number of the switch or chassis. SYNOPSIS ww
1154 Fabric OS Command Reference53-1003108-01wwn2To display the WWN on a Brocade 5100:switch:admin> wwn 10:00:00:05:1e:7a:7a:00To display the WWN
Fabric OS Command Reference 115553-1003108-01wwnAddress2wwnAddressBinds an FC Port ID to a device WWN. SYNOPSIS wwnaddress --bind [WWN] [PID]wwnaddres
1156 Fabric OS Command Reference53-1003108-01wwnAddress2--showDisplays all WWN-PID entries currently present in the partition.--findPIDDisplays the PI
Fabric OS Command Reference 115753-1003108-01zone2zonePerforms specific zone operations, manages Traffic Isolation (TI) Zones, and Frame Redirect (RD)
1158 Fabric OS Command Reference53-1003108-01zone2• TI within edge fabric routes traffic between a real device and a Proxy device to a specified EX_P
Fabric OS Command Reference 115953-1003108-01zone2OPERANDS This command takes as an operand an action and its associated arguments. When executed with
1160 Fabric OS Command Reference53-1003108-01zone2modeSpecifies the zone database location. This operand is optional. If no mode option is specified,
Fabric OS Command Reference 116153-1003108-01zone2nDisables failover mode. In non-failover mode, when the last interswitch link (ISL) of a TI Zone goe
Fabric OS Command Reference 9153-1003108-01bottleneckMon2To enable backend port credit recovery with the link reset threshold option and to display th
1162 Fabric OS Command Reference53-1003108-01zone23. Creating and managing RD Zones--rdcreateCreates a RD Zone for the specified members. The followin
Fabric OS Command Reference 116353-1003108-01zone2The reason for not being in the current enforcement table could be one of the following: • The devic
1164 Fabric OS Command Reference53-1003108-01zone2 zone: t_r_a_f_f_i_c_i_s_o_prop__zn 1,3*; 2,3* ------------------------------------
Fabric OS Command Reference 116553-1003108-01zone2To add the option to disable failover for a TI zone:switch:admin> zone --add -o n purplezoneTo ad
1166 Fabric OS Command Reference53-1003108-01zone2To display a specified zone in the defined configuration:switch:admin> zone --show ti_red Define
Fabric OS Command Reference 116753-1003108-01zone2To troubleshoot TI zone problems:switch:admin> zone --showTIerrors My Domain: 1Error type:
1168 Fabric OS Command Reference53-1003108-01zone2To display the newly created zone objects:switch:admin> cfgshowDefined configuration: cfg: myHT
Fabric OS Command Reference 116953-1003108-01zoneAdd2zoneAddAdds a member to the zone. SYNOPSIS zoneadd "zoneName", "member[;member...]
1170 Fabric OS Command Reference53-1003108-01zoneAdd2 alias: jones 7,3; 4,5 alias: zeus 4,7; 6,8; 9,2Effective configuration:No Effecti
Fabric OS Command Reference 117153-1003108-01zoneCreate2zoneCreateCreates a zone. SYNOPSIS zonecreate "zonename", "member[;member...]&q
xii Fabric OS Command Reference53-1003108-01fwClassInit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
92 Fabric OS Command Reference53-1003108-01bpPortLoopbackTest2bpPortLoopbackTestSends and receives data from the same BP port to perform a functional
1172 Fabric OS Command Reference53-1003108-01zoneCreate2When creating a zone, you can combine different ways of specifying zone members. For example,
Fabric OS Command Reference 117353-1003108-01zoneDelete2zoneDeleteDeletes a zone. SYNOPSIS zonedelete "zonename"DESCRIPTION Use this command
1174 Fabric OS Command Reference53-1003108-01zoneHelp2zoneHelpDisplays a description of zoning commands. SYNOPSIS zonehelpDESCRIPTION Use this command
Fabric OS Command Reference 117553-1003108-01zoneObjectCopy2zoneObjectCopyCopies a zone object. SYNOPSIS zoneObjectCopy "objectName", "
1176 Fabric OS Command Reference53-1003108-01zoneObjectExpunge2zoneObjectExpungeExpunges a zone object. SYNOPSIS zoneObjectExpunge "objectName&qu
Fabric OS Command Reference 117753-1003108-01zoneObjectExpunge2 21:00:00:20:37:0c:71:02 alias: array2 21:00:00:20:37:0c:76:22;
1178 Fabric OS Command Reference53-1003108-01zoneObjectRename2zoneObjectRenameRenames a zone object. SYNOPSIS zoneObjectRename "objectName",
Fabric OS Command Reference 117953-1003108-01zoneObjectReplace2zoneObjectReplaceReplaces zone members.SYNOPSIS zoneobjectreplace oldmember newmemberzo
1180 Fabric OS Command Reference53-1003108-01zoneRemove2zoneRemoveRemoves a member from a zone. SYNOPSIS zoneremove "zonename", "zoneMe
Fabric OS Command Reference 118153-1003108-01zoneRemove2 40:00:00:05:1e:a1:cd:04 alias: jones 7,3; 4,5 alias: zeus 4,7; 6,8; 9,2Eff
Fabric OS Command Reference 9353-1003108-01bpPortLoopbackTest2At each pass, a different data type is used to create the frame from a palette of seven.
1182 Fabric OS Command Reference53-1003108-01zoneShow2zoneShowDisplays zone information.SYNOPSIS zoneshow [--sort] [pattern][, mode]zoneshow [--ic] [p
Fabric OS Command Reference 118353-1003108-01zoneShow2--transdiffsonlyDisplays only the changes in the current transaction.--helpDisplays the command
1184 Fabric OS Command Reference53-1003108-01zoneShow2To display the changes in the current transaction: switch:admin> zoneshow --transdiffsDefined
Fabric OS Command Reference 118553-1003108-01Chapter3Primary FCS CommandsPrimary FCS commandsTable 6 summarizes the commands that are available only o
1186 Fabric OS Command Reference53-1003108-01Primary FCS commands3secPolicyActivate Must be run from the primary FCS switch.secPolicyAdd Must be run f
Fabric OS Command Reference 118753-1003108-01AppendixACommand AvailabilityCommand validation checksBefore a command is executed, it is validated again
1188 Fabric OS Command Reference53-1003108-01Command Admin Domain and Virtual Fabrics restrictionsAVirtual Fabric commands are further constrained by
Fabric OS Command Reference 118953-1003108-01Command Admin Domain and Virtual Fabrics restrictionsAbladeCfgGemode PortMember CH N/AbladeDisable Switch
1190 Fabric OS Command Reference53-1003108-01Command Admin Domain and Virtual Fabrics restrictionsAconfigDownload Allowed VF/CH N/AconfigList Allowed
Fabric OS Command Reference 119153-1003108-01Command Admin Domain and Virtual Fabrics restrictionsAfabricName Disallowed VF AllfabricPrincipal Disall
94 Fabric OS Command Reference53-1003108-01bpPortLoopbackTest28Runs test at 8 Gbps (Default for Condor2).16Runs test at 16 Gbps (Condor3 only).-bpport
1192 Fabric OS Command Reference53-1003108-01Command Admin Domain and Virtual Fabrics restrictionsAfcrRouteShow Allowed VF BSfcrXlateConfig Allowed/Sw
Fabric OS Command Reference 119353-1003108-01Command Admin Domain and Virtual Fabrics restrictionsAgePortErrShow Allowed VF Allh Allowed Disallowed N/
1194 Fabric OS Command Reference53-1003108-01Command Admin Domain and Virtual Fabrics restrictionsAlinkCost Allowed/SwitchMember VF AlllogicalGroup Sw
Fabric OS Command Reference 119553-1003108-01Command Admin Domain and Virtual Fabrics restrictionsApasswd Allowed VF/CH N/ApasswdCfg SwitchMember CH
1196 Fabric OS Command Reference53-1003108-01Command Admin Domain and Virtual Fabrics restrictionsAportCfgFec PortMember VF AllportCfgfFillword PortMe
Fabric OS Command Reference 119753-1003108-01Command Admin Domain and Virtual Fabrics restrictionsAportLogEventShow Allowed VF AllportLoginShow PortMe
1198 Fabric OS Command Reference53-1003108-01Command Admin Domain and Virtual Fabrics restrictionsAsecActiveSize AD0/Disallowed VF AllsecAuthSecret AD
Fabric OS Command Reference 119953-1003108-01Command Admin Domain and Virtual Fabrics restrictionsAsupportFfdc SwitchMember CH N/AsupportFtp SwitchMem
1200 Fabric OS Command Reference53-1003108-01Command Admin Domain and Virtual Fabrics restrictionsAtsTimeZone SwitchMember/Allowed CH N/AturboRamTest
Fabric OS Command Reference 9553-1003108-01bpTurboRamTest2bpTurboRamTestMBIST test for AP Blade BP ASICs. SYNOPSIS bpturboramtest [--slot slot] [
96 Fabric OS Command Reference53-1003108-01bpTurboRamTest2EXAMPLES To run the test in default mode:switch:admin> bpturboramtest Running bpturboramt
Fabric OS Command Reference 9753-1003108-01bufOpMode2bufOpModeChanges or displays the Buffer Optimized Mode. SYNOPSIS bufopmode --set slot [-f]bufopmo
98 Fabric OS Command Reference53-1003108-01bufOpMode2Slot 9: buffer optimized mode - OffSlot 10: buffer optimized mode - OffSlot 11: buffer optimized
Fabric OS Command Reference 9953-1003108-01bufOpMode2Slot 11: buffer optimized mode - Off*Slot 12: buffer optimized mode - Off*-----------------------
100 Fabric OS Command Reference53-1003108-01ceePortLedTest2ceePortLedTestDESCRIPTION See portLedTest.SEE ALSO None
Fabric OS Command Reference 10153-1003108-01ceePortLoopbackTest2ceePortLoopbackTestDESCRIPTION See portLoopbackTest.SEE ALSO None
Fabric OS Command Reference xiii53-1003108-01itemList . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
102 Fabric OS Command Reference53-1003108-01ceeTurboRamTest2ceeTurboRamTestDESCRIPTION See turboRamTest.SEE ALSO None
Fabric OS Command Reference 10353-1003108-01cfgActvShow2cfgActvShowDisplays effective zone configuration information. SYNOPSIS cfgactvshowDESCRIPTION
104 Fabric OS Command Reference53-1003108-01cfgAdd2cfgAddAdds a member to a zone configuration. SYNOPSIS cfgadd "cfgName", "member[; me
Fabric OS Command Reference 10553-1003108-01cfgClear2cfgClearClears all zone configurations. SYNOPSIS cfgclearDESCRIPTION Use this command to clear al
106 Fabric OS Command Reference53-1003108-01cfgCreate2cfgCreateCreates a zone configuration. SYNOPSIS cfgcreate "cfgName", "member[;mem
Fabric OS Command Reference 10753-1003108-01cfgDelete2cfgDeleteDeletes a zone configuration. SYNOPSIS cfgdelete "cfgName"DESCRIPTION Use thi
108 Fabric OS Command Reference53-1003108-01cfgDisable2cfgDisableDisables a zone configuration. SYNOPSIS cfgdisableDESCRIPTION Use this command to dis
Fabric OS Command Reference 10953-1003108-01cfgEnable2cfgEnableEnables a zone configuration. SYNOPSIS cfgenable "cfgName"DESCRIPTION Use thi
110 Fabric OS Command Reference53-1003108-01cfgEnable2switch:admin> cfgtransabort 271010736switch:admin> cfgenable "USA_cfg"You are ab
Fabric OS Command Reference 11153-1003108-01cfgRemove2cfgRemoveRemoves a member from a zone configuration. SYNOPSIS cfgremove "cfgName",&quo
xiv Fabric OS Command Reference53-1003108-01nbrStatsClear . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
112 Fabric OS Command Reference53-1003108-01cfgSave2cfgSaveSaves the zone configuration to nonvolatile memory. SYNOPSIS cfgsaveDESCRIPTION Use this co
Fabric OS Command Reference 11353-1003108-01cfgSave2switch:admin> cfgsaveYou are about to save the Defined zoning configuration. Thisaction will on
114 Fabric OS Command Reference53-1003108-01cfgShow2cfgShowDisplays zone configuration information. SYNOPSIS cfgshow [--ic] ["pattern"] [, m
Fabric OS Command Reference 11553-1003108-01cfgShow2"pattern"A regular expression that matches zone configuration names. The pattern must be
116 Fabric OS Command Reference53-1003108-01cfgShow2 21:00:00:20:37:0c:76:28zone: Red_zone 1,0 21:00:00:20:37:0c:76:85 21
Fabric OS Command Reference 11753-1003108-01cfgSize2cfgSizeDisplays zone and Admin Domain database size details. SYNOPSIS cfgsize [integer]DESCRIPTION
118 Fabric OS Command Reference53-1003108-01cfgSize2EXAMPLES To display the zone database on a Brocade 6510switch:admin> cfgsizeZone DB max size -
Fabric OS Command Reference 11953-1003108-01cfgTransAbort2cfgTransAbortAborts the current zoning transaction. SYNOPSIS cfgtransabort [token]DESCRIPTIO
120 Fabric OS Command Reference53-1003108-01cfgTransShow2cfgTransShowDisplays information about the current zoning transaction. SYNOPSIS cfgtransshowc
Fabric OS Command Reference 12153-1003108-01cfgTransShow2To display the current transaction and the list of domains with open transactions: switch:adm
Fabric OS Command Reference xv53-1003108-01portCfgCreditRecovery . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 715por
122 Fabric OS Command Reference53-1003108-01chassisBeacon2chassisBeaconSets chassis beaconing mode. SYNOPSIS chassisbeacon [mode]DESCRIPTION Use this
Fabric OS Command Reference 12353-1003108-01chassisBeacon2To display the chassis beaconing mode:switch:admin> chassisbeaconValue = 0SEE ALSO portBe
124 Fabric OS Command Reference53-1003108-01chassisCfgPerrThreshold2chassisCfgPerrThresholdConfigures parity error threshold and fault capability on a
Fabric OS Command Reference 12553-1003108-01chassisCfgPerrThreshold2To display the configuration:switch:admin> chassiscfgperrthreshold --showConfig
126 Fabric OS Command Reference53-1003108-01chassisDisable2chassisDisableDisables all user ports in a chassis. SYNOPSIS chassisdisable [-force]DESCRIP
Fabric OS Command Reference 12753-1003108-01chassisDistribute2chassisDistributeDistributes IP filter policies. SYNOPSIS chassisdistribute -db ipfilter
128 Fabric OS Command Reference53-1003108-01chassisDistribute2OPERANDS This command has the following operands:-db ipfilterSpecifies the policy databa
Fabric OS Command Reference 12953-1003108-01chassisEnable2chassisEnableEnables all user ports in a chassis. SYNOPSIS chassisenableDESCRIPTION Use this
130 Fabric OS Command Reference53-1003108-01chassisName2chassisNameDisplays or sets the chassis name. SYNOPSIS chassisname [name]DESCRIPTION Use this
Fabric OS Command Reference 13153-1003108-01chassisShow2chassisShowDisplays all field replaceable units (FRUs). SYNOPSIS chassisshowDESCRIPTION Use th
xvi Fabric OS Command Reference53-1003108-01portLedTest . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
132 Fabric OS Command Reference53-1003108-01chassisShow2NOTES The execution of this command is subject to Virtual Fabric or Admin Domain restrictions
Fabric OS Command Reference 13353-1003108-01classConfig2classConfigDisplays RBAC class permissions. SYNOPSIS classconfig --show class_name | -all | -c
134 Fabric OS Command Reference53-1003108-01classConfig2--showcli commandDisplays the RBAC permissions for the specified command and associated comman
Fabric OS Command Reference 13553-1003108-01classConfig2 44. PhysicalComputerSystem 45. PKI 46. PortMirror 47. RADIUS 48. Reboot 49. Restricted
136 Fabric OS Command Reference53-1003108-01classConfig2To display the RBAC permissions for the UserManagement class:switch:admin> classconfig --sh
Fabric OS Command Reference 13753-1003108-01cliHistory2cliHistoryDisplays switch command history. SYNOPSIS clihistoryclihistory --showclihistory --sho
138 Fabric OS Command Reference53-1003108-01cliHistory2switch:admin> firmwaredownload -s -p scp 10.70.4.109,fvt,/dist,pray4greenServer IP: 10.70.4.
Fabric OS Command Reference 13953-1003108-01cmsh2cmshOpens the CEE command shell. SYNOPSIS cmshDESCRIPTION Use this command to open a shell for managi
140 Fabric OS Command Reference53-1003108-01cmsh2To create an FCoE VLAN:switch:admin> cmshswitch:admin>enswitch:admin>#conf tswitch:admin>
Fabric OS Command Reference 14153-1003108-01configDefault2configDefaultResets the nonpersistent configuration data to factory defaults. SYNOPSIS confi
Fabric OS Command Reference xvii53-1003108-01rasAdmin . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
142 Fabric OS Command Reference53-1003108-01configDefault2OPERANDS This command has the following operands:-fid FIDSpecifies the Fabric ID of the logi
Fabric OS Command Reference 14353-1003108-01configDownload2configDownloadDownloads configuration data to the system. SYNOPSIS configdownloadconfigdown
144 Fabric OS Command Reference53-1003108-01configDownload2The system configuration data is downloaded separately. It is grouped into chassis informat
Fabric OS Command Reference 14553-1003108-01configDownload2• After the switch is enabled, if the switch is the primary FCS, then its security and zoni
146 Fabric OS Command Reference53-1003108-01configDownload2-vfDownloads the Virtual Fabric configuration (switch-conf_xx.txt) instead of the regular s
Fabric OS Command Reference 14753-1003108-01configDownload2DIAGNOSTICS The configuration download may fail for one or more of the following reasons:•
148 Fabric OS Command Reference53-1003108-01configDownload2To download all system configuration data for the chassis and all logical switches (require
Fabric OS Command Reference 14953-1003108-01configList2configListLists uploaded configuration files. SYNOPSIS configlist -local | -USB | -UDESCRIPTION
150 Fabric OS Command Reference53-1003108-01configRemove2configRemoveDeletes a saved configuration file. SYNOPSIS configremove -local | -USB | -U [fil
Fabric OS Command Reference 15153-1003108-01configShow2configShowDisplays system configuration settings. SYNOPSIS configshowconfigshow [-all | -fid FI
xviii Fabric OS Command Reference53-1003108-01snmpTraps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
152 Fabric OS Command Reference53-1003108-01configShow2-local [file]Displays the content of a configuration file that was previously created by config
Fabric OS Command Reference 15353-1003108-01configShow2passwdcfg.maxpasswordage:0passwdcfg.warning:0passwdcfg.lockoutthreshold:0passwdcfg.lockoutdurat
154 Fabric OS Command Reference53-1003108-01configShow2passwdcfg.lockoutduration:30passwdcfg.adminlockout:0passwdcfg.repeat:1passwdcfg.sequence:1passw
Fabric OS Command Reference 15553-1003108-01configUpload2configUploadUploads system configuration data to a file. SYNOPSIS configuploadconfigupload [-
156 Fabric OS Command Reference53-1003108-01configUpload2The system configuration data is uploaded separately. It is grouped into chassis information
Fabric OS Command Reference 15753-1003108-01configUpload2-fid FIDUploads switch configuration data from a logical switch specified by its fabric ID. T
158 Fabric OS Command Reference53-1003108-01configUpload2EXAMPLES To upload the switch configuration interactively from a switch that is not enabled f
Fabric OS Command Reference 15953-1003108-01configure2configureChanges switch configuration settings. SYNOPSIS configureDESCRIPTION Use this command t
160 Fabric OS Command Reference53-1003108-01configure2The following parameters can be modified with the configure command:Fabric ParametersFabric sett
Fabric OS Command Reference 16153-1003108-01configure2WWN Based persistent PIDWhen enabled, this feature supports both dynamic and static WWN-based PI
Fabric OS Command Reference xix53-1003108-01traceDump . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
162 Fabric OS Command Reference53-1003108-01configure21The unique area assignments begin at zero regardless of where the port is physically located. T
Fabric OS Command Reference 16353-1003108-01configure2Disable Device ProbingWhen disable device probing is set to 1, devices that do not register with
164 Fabric OS Command Reference53-1003108-01configure2The edge hold time parameter is enabled by default with a value of 220 milliseconds. The followi
Fabric OS Command Reference 16553-1003108-01configure2Maximum logins per switchSets a switch-wide limit on allowed logins. The maximum login per switc
166 Fabric OS Command Reference53-1003108-01configure2Domain RSCN to End-deviceValues are as follows:0Disabled. No domain RSCN is sent to the end-devi
Fabric OS Command Reference 16753-1003108-01configure2 Checking and Warning boolean yes yes/no Allow Fabric Event
168 Fabric OS Command Reference53-1003108-01configure2Portlog events enable (yes, y, no, n): [no] ssl attributes (yes, y, no, n): [no]rpcd attributes
Fabric OS Command Reference 16953-1003108-01configureChassis2configureChassisChanges chassis-level system configuration settings. SYNOPSIS configurech
170 Fabric OS Command Reference53-1003108-01configureChassis2System attributesThe following system-related parameters are configurable on a Virtual Fa
Fabric OS Command Reference 17153-1003108-01configureChassis2NOTES The execution of this command is subject to Virtual Fabric or Admin Domain restrict
Copyright © 2013 Brocade Communications Systems, Inc. All Rights Reserved.ADX, AnyIO, Brocade, Brocade Assurance, the B-wing symbol, DCX, Fabric OS, I
xx Fabric OS Command Reference53-1003108-01
172 Fabric OS Command Reference53-1003108-01creditRecovMode2creditRecovModeEnables credit loss recovery on back-end ports and time-out based credit lo
Fabric OS Command Reference 17353-1003108-01creditRecovMode2The --fe_crdloss option is supported only on Condor 2-based front-end interswitch link (IS
174 Fabric OS Command Reference53-1003108-01creditRecovMode2--showDisplays the backend port credit recovery configuration as enabled or disabled. In a
Fabric OS Command Reference 17553-1003108-01cryptoCfg2cryptoCfgPerforms encryption configuration and management functions. SYNOPSIS cryptocfg --help -
176 Fabric OS Command Reference53-1003108-01cryptoCfg2cryptocfg --initnodecryptocfg --initEE [slot]cryptocfg --regEE [slot]cryptocfg --enableEE [slot]
Fabric OS Command Reference 17753-1003108-01cryptoCfg2• Group-wide policy configuration.• Zeroization of all critical security parameters on the local
178 Fabric OS Command Reference53-1003108-01cryptoCfg2Some of the certificates generated with this command may need to be exported so that they can be
Fabric OS Command Reference 17953-1003108-01cryptoCfg2--exportExports a certificate from the local encryption switch or blade to a specified external
180 Fabric OS Command Reference53-1003108-01cryptoCfg2Files to be imported include member node CP certificates and key vault certificates. Use the cry
Fabric OS Command Reference 18153-1003108-01cryptoCfg2--dereg -membernodeRemoves the registration for the specified member node. This command is valid
Fabric OS Command Reference xxi53-1003108-01About This DocumentHow this document is organizedThis document is organized to help you find the informati
182 Fabric OS Command Reference53-1003108-01cryptoCfg2For the SKM, run this command only for the primary key vault. The login credential must match a
Fabric OS Command Reference 18353-1003108-01cryptoCfg2diagRuns diagnostic tests including retrieval, archival and synchronization of the tests in the
184 Fabric OS Command Reference53-1003108-01cryptoCfg2To register a member node with the group leader:SecurityAdmin:switch> cryptocfg --reg \ -
Fabric OS Command Reference 18553-1003108-01cryptoCfg210:00:00:05:1e:47:30:00/3 10.32.72.105 EE_STATE_ONLINE Reachable10:00:00:05:1e:47:30:00/10 10.3
186 Fabric OS Command Reference53-1003108-01cryptoCfg2To display the key vault diagnostics configuration:switch:admin> cryptocfg --kvdiag -showKey
Fabric OS Command Reference 18753-1003108-01cryptoCfg2cryptocfg --leave_encryption_groupcryptocfg --genmasterkeycryptocfg --exportmasterkey [-file]cry
188 Fabric OS Command Reference53-1003108-01cryptoCfg2- State: connected, disconnected, up, authentication failure, or unknown.- Type: LKM, DPM, SKM,
Fabric OS Command Reference 18953-1003108-01cryptoCfg2• For each node, the display includes the following parameters:- Node Name: the node WWN- State:
190 Fabric OS Command Reference53-1003108-01cryptoCfg2--delete -encgroupDeletes an encryption group with the specified name. This command is valid onl
Fabric OS Command Reference 19153-1003108-01cryptoCfg2primary | secondary Specifies the signing key vault as primary or secondary. This operand is val
xxii Fabric OS Command Reference53-1003108-01Although Brocade supports and tests many different software and hardware configurations for Fabric OS v7.
192 Fabric OS Command Reference53-1003108-01cryptoCfg2manualEnables manual failback. In this mode, failback must be initiated manually after an encryp
Fabric OS Command Reference 19353-1003108-01cryptoCfg2This command is required only when a node that was earlier part of encryption group (online and
194 Fabric OS Command Reference53-1003108-01cryptoCfg2once. Each time you export the same master key, the associate key ID is incremented, and both th
Fabric OS Command Reference 19553-1003108-01cryptoCfg2--sync -encgroupManually synchronizes the encryption group database belonging to the group leade
196 Fabric OS Command Reference53-1003108-01cryptoCfg2To register a NetApp LKM appliance as the primary key vault "LKM1":SecurityAdmin:switc
Fabric OS Command Reference 19753-1003108-01cryptoCfg2To export the master key to a file:SecurityAdmin:switch> cryptocfg --exportmasterkey -fileEnt
198 Fabric OS Command Reference53-1003108-01cryptoCfg2 Key Vault/CA Certificate Validity: Yes Port for Key Vault Connection: 32579
Fabric OS Command Reference 19953-1003108-01cryptoCfg2To display the encryption group member information:SecurityAdmin:switch> cryptocfg --show -gr
200 Fabric OS Command Reference53-1003108-01cryptoCfg2To display encryption performance:SecurityAdmin:switch> cryptocfg --perfshow 33 32 3
Fabric OS Command Reference 20153-1003108-01cryptoCfg2- HA cluster name: user-defined label- Number of encryption engine entries: numeric value- HA cl
Fabric OS Command Reference xxiii53-1003108-01Modified commandsThe following commands and associated man pages have been corrected or updated with add
202 Fabric OS Command Reference53-1003108-01cryptoCfg2--add -haclustermemberAdds one or more encryption engine members to an already configured HA. A
Fabric OS Command Reference 20353-1003108-01cryptoCfg2--show -haclusterDisplays the specified HA clusters in the encryption group and associated state
204 Fabric OS Command Reference53-1003108-01cryptoCfg2To replace an encryption engine in HA cluster "HAC2":SecurityAdmin:switch> cryptocf
Fabric OS Command Reference 20553-1003108-01cryptoCfg2 new_node_WWN [new_slot]cryptocfg --add -initiator crypto_target_container_name initiato
206 Fabric OS Command Reference53-1003108-01cryptoCfg2cryptocfg --resume_rekey crypto_target_container_name LUN_Num initiator_PWWNcryptocfg --disc
Fabric OS Command Reference 20753-1003108-01cryptoCfg2CTC configuration uses a transaction model. Configuration changes must be committed before they
208 Fabric OS Command Reference53-1003108-01cryptoCfg2- Encrypt existing data: disabled or enabled- Rekey: disabled or enabled- Key life: the key life
Fabric OS Command Reference 20953-1003108-01cryptoCfg2• Key life (in days); number of days until expiration• Rekey status: numeric value• Key expirati
210 Fabric OS Command Reference53-1003108-01cryptoCfg2- Tape policy type: pool-based or LUN-based- Key life: key lifespan in days- Volume/pool label-
Fabric OS Command Reference 21153-1003108-01cryptoCfg2- Volume/pool label: user-defined label- Rekey status: numeric valueIf rekey- or tape sessions a
xxiv Fabric OS Command Reference53-1003108-01Document conventionsThis section describes text formatting conventions and important notices formats. Tex
212 Fabric OS Command Reference53-1003108-01cryptoCfg2• Number of rekey sessions in progress: numeric value• For each rekey session the display includ
Fabric OS Command Reference 21353-1003108-01cryptoCfg2NOTES Encryption groups and HA clusters must be configured before performing any CryptoTarget co
214 Fabric OS Command Reference53-1003108-01cryptoCfg2This operand is optional. You may add initiators at the time when the CTC is created or any time
Fabric OS Command Reference 21553-1003108-01cryptoCfg2--add -initiatorAdds one or more initiators to an existing CTC. An initiator that is added to a
216 Fabric OS Command Reference53-1003108-01cryptoCfg2LUN policies are configured per HA or DEK cluster. For multi-path LUNs exposed through multiple
Fabric OS Command Reference 21753-1003108-01cryptoCfg2-newLUNIndicates that the LUN created does not contain any user data and will be part of a repli
218 Fabric OS Command Reference53-1003108-01cryptoCfg2• The -key_lifespan parameter cannot be modified for tape LUNs once it has been set. • Exercise
Fabric OS Command Reference 21953-1003108-01cryptoCfg2This command is valid only on the group leader. The following operands are supported:-label pool
220 Fabric OS Command Reference53-1003108-01cryptoCfg2--manual_rekeyPerforms a manual rekeying of a specified LUN associated with a specified CTC. Man
Fabric OS Command Reference 22153-1003108-01cryptoCfg2--show -containerDisplays all CTCs in the encryption group. This command is valid on all nodes.
Fabric OS Command Reference xxv53-1003108-01NOTEA note provides a tip, guidance, or advice, emphasizes important information, or provides a reference
222 Fabric OS Command Reference53-1003108-01cryptoCfg2--show -rekeyDisplays information about rekey sessions in progress. This command is valid on all
Fabric OS Command Reference 22353-1003108-01cryptoCfg2LUN_NumSpecifies the number of the LUN whose metadata needs to be reread.initiator_PWWNSpecifies
224 Fabric OS Command Reference53-1003108-01cryptoCfg2nscamshow for remote switches:Switch entry for 2 state rev owner known v611 0xfffc01 Device lis
Fabric OS Command Reference 22553-1003108-01cryptoCfg2Number of host(s): 1Configuration status:committedHost: 10:00:00:00:c9:2b:c9:3a
226 Fabric OS Command Reference53-1003108-01cryptoCfg2Rekey: disabledInternal EE LUN state: Encryption enabledEncryption algor
Fabric OS Command Reference 22753-1003108-01cryptoCfg2To display the tape pool configuration:FabricAdmin:switch> cryptocfg --show -container -all -
228 Fabric OS Command Reference53-1003108-01cryptoCfg2To display CryptoTarget container runtime status information For a disk LUN with rekeying enable
Fabric OS Command Reference 22953-1003108-01cryptoCfg2Encryption format: nativeEncrypt existing data: enabledRekey: enabl
230 Fabric OS Command Reference53-1003108-01cryptoCfg2To reclaim all WWNs associated with a member node when no containers are present on the node:swi
Fabric OS Command Reference 23153-1003108-01cryptoCfg2OPERANDS The cryptoCfg transaction management function has the following operands:--help transcf
xxvi Fabric OS Command Reference53-1003108-01Additional informationThis section lists additional Brocade and industry-specific documentation that you
232 Fabric OS Command Reference53-1003108-01cryptoCfg2• All nodes in the encryption group must run Fabric OS v6.4.0 or later when keyvault type is set
Fabric OS Command Reference 23353-1003108-01cryptoCfg22. Display the key IDs to be deleted manually from the keyvault switch:admin> cryptocfg --sho
234 Fabric OS Command Reference53-1003108-01dataTypeShow2dataTypeShowDisplays sample data stream types used in some diagnostic commands. SYNOPSIS data
Fabric OS Command Reference 23553-1003108-01date2dateDisplays or sets the switch date and time. SYNOPSIS date ["newdate"]DESCRIPTION Use thi
236 Fabric OS Command Reference53-1003108-01date2EXAMPLES To display the current date and time and then modify it: switch:admin> dateTue Oct 22 14:
Fabric OS Command Reference 23753-1003108-01dbgShow2dbgShowDisplays current values of debug and verbosity levels of the specified module. SYNOPSIS dbg
238 Fabric OS Command Reference53-1003108-01defZone2defZoneSets or displays the default zone access mode. SYNOPSIS defzone [--noaccess | --allaccess |
Fabric OS Command Reference 23953-1003108-01defZone2A cfgSave, cfgEnable, or cfgDisable command must be performed subsequent to the use of this comman
240 Fabric OS Command Reference53-1003108-01diagClearError2diagClearErrorClears the diagnostics failure status. SYNOPSIS diagclearerror [[--slot] slot
Fabric OS Command Reference 24153-1003108-01diagDisablePost2diagDisablePostDisables the power-on self-test (POST). SYNOPSIS diagdisablepostDESCRIPTION
Fabric OS Command Reference xxvii53-1003108-01• Switch operating system version• Error numbers and messages received• supportSave command output• Deta
242 Fabric OS Command Reference53-1003108-01diagEnablePost2diagEnablePostEnables the power-on self-test (POST). SYNOPSIS diagenablepostDESCRIPTION Use
Fabric OS Command Reference 24353-1003108-01diagHelp2diagHelpDisplays diagnostic command information. SYNOPSIS diaghelpDESCRIPTION Use this command to
244 Fabric OS Command Reference53-1003108-01diagPost2diagPostDisplays the diagnostic power-on self-test (POST) configuration. SYNOPSIS diagpostDESCRIP
Fabric OS Command Reference 24553-1003108-01diagRetry2diagRetrySets or displays diagnostic retry mode. SYNOPSIS diagretry [mode | -show]DESCRIPTION Us
246 Fabric OS Command Reference53-1003108-01diagShow2diagShowDisplays diagnostics status. SYNOPSIS diagshow [--slot number] [-uports itemlist]
Fabric OS Command Reference 24753-1003108-01distribute2distributeDistributes data to switches in a fabric. SYNOPSIS distribute -p policy_list -d switc
248 Fabric OS Command Reference53-1003108-01distribute2To distribute the Switch Connection Control Policy, Fabric Configuration Server Policy, and Pas
Fabric OS Command Reference 24953-1003108-01dlsReset2dlsResetDisables Dynamic Load Sharing (DLS). SYNOPSIS dlsresetDESCRIPTION Use this command to dis
250 Fabric OS Command Reference53-1003108-01dlsSet2dlsSetEnables Dynamic Load Sharing (DLS) without frame loss. SYNOPSIS dlssetdlsset --enable -lossle
Fabric OS Command Reference 25153-1003108-01dlsSet2NOTES For switches running Fabric OS v7.1.0 or later, you can enable Lossless (or enable Fabric Man
xxviii Fabric OS Command Reference53-1003108-01
252 Fabric OS Command Reference53-1003108-01dlsSet2switch:admin> dlsresetDLS can not be changed with current routing policyswitch:admin> dlssetD
Fabric OS Command Reference 25353-1003108-01dlsSet2To attempt to enable Lossless while XISL use is enabled:switch:admin> dlsset --enable -losslessL
254 Fabric OS Command Reference53-1003108-01dlsShow2dlsShowDisplays the setting of the Dynamic Load Sharing (DLS) option. SYNOPSIS dlsshowDESCRIPTION
Fabric OS Command Reference 25553-1003108-01dnsConfig2dnsConfigSets, displays, or removes domain name service (DNS) parameters. SYNOPSIS dnsconfigdnsc
256 Fabric OS Command Reference53-1003108-01dnsConfig2Enter Name Server IP address in dot notation: [] \ 123.123.123.123Enter Name Server IP addres
Fabric OS Command Reference 25753-1003108-01enclosureShow2enclosureShowDisplays attributes of the switch enclosure. SYNOPSIS enclosureshow attributeDE
258 Fabric OS Command Reference53-1003108-01enclosureShow2connfuseInformation about whether or not the switch has a fuse. uuidThe Universal Unique ID
Fabric OS Command Reference 25953-1003108-01errClear2errClearClears all error log messages for all switch instances on this Control Processor (CP). SY
260 Fabric OS Command Reference53-1003108-01errDelimiterSet2errDelimiterSetSets the error log start and end delimiters for messages sent to the consol
Fabric OS Command Reference 26153-1003108-01errDump2errDumpDisplays the error log without pagination. SYNOPSIS errdump [--all]errdump [--count number]
Fabric OS Command Reference 153-1003108-01Chapter1Using Fabric OS CommandsUsing the command line interfaceThe Fabric OS command line interface (CLI),
262 Fabric OS Command Reference53-1003108-01errDump2NOTES The execution of this command is subject to Virtual Fabric or Admin Domain restrictions that
Fabric OS Command Reference 26353-1003108-01errDump2To display messages for a slot: switch:admin> errdump --slot 4Fabric OS: v7.1.02012/06/19-03:26
264 Fabric OS Command Reference53-1003108-01errDump22012/06/18-20:24:52, [SULB-1001], 2, SLOT 5 | CHASSIS, WARNING, \ pluto_19, Firmwaredownload com
Fabric OS Command Reference 26553-1003108-01errFilterSet2errFilterSetSets a filter for an error log destination. SYNOPSIS errfilterset [-d destination
266 Fabric OS Command Reference53-1003108-01errModuleShow2errModuleShowDisplays all the defined error log modules. SYNOPSIS errmoduleshowDESCRIPTION U
Fabric OS Command Reference 26753-1003108-01errShow2errShowDisplays the error log messages with pagination. SYNOPSIS errshow [-a | -r]DESCRIPTION Use
268 Fabric OS Command Reference53-1003108-01errShow2EXAMPLES To display the error log for the chassis: switch:admin> errshow -aFabric OS: v7.2.0201
Fabric OS Command Reference 26953-1003108-01exit2exitDESCRIPTION See logout.SEE ALSO None
270 Fabric OS Command Reference53-1003108-01fabRetryShow2fabRetryShowDisplays the retry count of the fabric commands. SYNOPSIS fabretryshowDESCRIPTION
Fabric OS Command Reference 27153-1003108-01fabRetryShow2NOTES The execution of this command is subject to Virtual Fabric or Admin Domain restrictions
Fabric OS Reference v4.1.2 53-0000519-05 August 2003Fabric OS Reference v4.1.2 53-0000519-06 October 2003Fabric OS Reference v4.2.0 53-0000519-07 Dece
2 Fabric OS Command Reference53-1003108-01Understanding Role-Based Access Control1In addition to these predefined roles, Fabric OS v7.0.0 and later pr
272 Fabric OS Command Reference53-1003108-01fabRetryStats2fabRetryStatsDisplays or manages the retry count of fabric commands.SYNOPSIS fabretrystats -
Fabric OS Command Reference 27353-1003108-01fabRetryStats2DIAG_CMDDiagnostic CommandNOTES The execution of this command is subject to Virtual Fabric o
274 Fabric OS Command Reference53-1003108-01fabricLog2fabricLogDisplays (all users) or manipulates (admin) the fabric log. SYNOPSIS fabriclog -s | --s
Fabric OS Command Reference 27553-1003108-01fabricLog2A3The non-Principal switch is processing an RDI.S0The switch is in offline state.PPort state. Po
276 Fabric OS Command Reference53-1003108-01fabricLog2NOTES The execution of this command is subject to Virtual Fabric or Admin Domain restrictions th
Fabric OS Command Reference 27753-1003108-01fabricLog2To display the cleared fabric log after the size was changed:switch:admin> fabriclog -sTime S
278 Fabric OS Command Reference53-1003108-01fabricName2fabricNameConfigures the fabric name parameter. SYNOPSIS fabricname --set fabric_namefabricname
Fabric OS Command Reference 27953-1003108-01fabricName2switch:user> fabricname --showFabric Name: "my new fabric"To clear the fabric name
280 Fabric OS Command Reference53-1003108-01fabricPrincipal2fabricPrincipalSets the principal switch selection mode. SYNOPSIS fabricprincipal --help |
Fabric OS Command Reference 28153-1003108-01fabricPrincipal20x01Highest priority. This is a user-defined value0x02Switch was principal prior to sendin
Fabric OS Command Reference 353-1003108-01Understanding Virtual Fabric restrictions1• Perform firmware download.• Perform regular Fabric OS management
282 Fabric OS Command Reference53-1003108-01fabricPrincipal2To display the principal switch selection priority:switch:admin> fabricprincipal --show
Fabric OS Command Reference 28353-1003108-01fabricShow2fabricShowDisplays fabric membership information. SYNOPSIS fabricshow [-membership | -chassis |
284 Fabric OS Command Reference53-1003108-01fabricShow2NOTES The execution of this command is subject to Virtual Fabric or Admin Domain restrictions t
Fabric OS Command Reference 28553-1003108-01fabricShow2To show additional details about the chassis:switch:admin> fabricshow -chassisSwitch ID
286 Fabric OS Command Reference53-1003108-01fabStatsShow2fabStatsShowDisplays fabric statistics. SYNOPSIS fabstatsshowDESCRIPTION Use this command to
Fabric OS Command Reference 28753-1003108-01fabStatsShow2NOTES The execution of this command is subject to Virtual Fabric or Admin Domain restrictions
288 Fabric OS Command Reference53-1003108-01fanDisable2fanDisableDisables a fan unit. SYNOPSIS fandisable unitDESCRIPTION Use this command to disable
Fabric OS Command Reference 28953-1003108-01fanEnable2fanEnableEnables a fan unit. SYNOPSIS fanenable unitDESCRIPTION Use this command to set a previo
290 Fabric OS Command Reference53-1003108-01fanShow2fanShowDisplays fan status and speed. SYNOPSIS fanshowDESCRIPTION Use this command to display the
Fabric OS Command Reference 29153-1003108-01faPwwn2faPwwnManages fabric-assigned port world wide names. SYNOPSIS fapwwn --enable -port [slot/]port[-po
4 Fabric OS Command Reference53-1003108-01Understanding Admin Domain restrictions1Understanding Admin Domain restrictionsA subset of Fabric OS command
292 Fabric OS Command Reference53-1003108-01faPwwn2A single port can be assigned up to two WWNs, one assigned automatically and one assigned by the us
Fabric OS Command Reference 29353-1003108-01faPwwn2The execution of this command is subject to Virtual Fabric or Admin Domain restrictions that may be
294 Fabric OS Command Reference53-1003108-01faPwwn2allSpecifies all ports on the logical switch. This operand is valid only with the --show option.--m
Fabric OS Command Reference 29553-1003108-01faPwwn2To assign an user-assigned FA-PWWN to an AG port:fapwwn --assign -ag 12:34:56:78:90:12:23:45 -port
296 Fabric OS Command Reference53-1003108-01faPwwn2 11:22:33:44:55:66:77:88 11403 Yes AG/User 52:00:10:00:00:0f:50:32 2:00:10:00:00:0f:50:33
Fabric OS Command Reference 29753-1003108-01fastBoot2fastBootReboots the Control Processor (CP), bypassing the Power-On Self-Test (POST). SYNOPSIS fas
298 Fabric OS Command Reference53-1003108-01fastBoot2To reboot a DCX without executing POST on startup (in the example, HA is enabled): switch:admin&g
Fabric OS Command Reference 29953-1003108-01fcipHelp2fcipHelpDisplays FCIP command information. SYNOPSIS fciphelpDESCRIPTION Use this command to displ
300 Fabric OS Command Reference53-1003108-01fcipLedTest2fcipLedTestExercises the GbE port LEDS on the Brocade 7800 and FX8-24. SYNOPSIS fcipledtest [s
Fabric OS Command Reference 30153-1003108-01fcipPathTest2fcipPathTestTests the data path of the FCIP complex. SYNOPSIS fcippathtest [--slot slot]
Fabric OS Command Reference 553-1003108-01Determining RBAC permissions for a specific command1switch:admin> classconfig --showcli zoneCLI Option
302 Fabric OS Command Reference53-1003108-01fcipPathTest2EXAMPLES To run the test on slot 2:switch:admin> fcippathtest --slot 2Running fcippathtest
Fabric OS Command Reference 30353-1003108-01fcoe2fcoeManages and displays FCoE configuration. SYNOPSIS fcoe --cfgshow [[slot/]port]fcoe --disable [slo
304 Fabric OS Command Reference53-1003108-01fcoe2--loginshowDisplays information about the devices logged in to the specified FCoE port.--fcmapsetConf
Fabric OS Command Reference 30553-1003108-01fcoe2Index Slot Port Address Media Speed State Proto==================================================
306 Fabric OS Command Reference53-1003108-01fcoe2To display FIP and FCMAP configuration on the Brocade FCoE10-24:switch:admin> fcoe --fipcfgshowFIP
Fabric OS Command Reference 30753-1003108-01fcoeLoginCfg2fcoeLoginCfgManages or displays the FCoE login configuration. SYNOPSIS fcoelogincfg --show
308 Fabric OS Command Reference53-1003108-01fcoeLoginCfg2--transshowDisplays the current configuration transaction in progress fabric-wide.--transabor
Fabric OS Command Reference 30953-1003108-01fcoeLoginCfg2To perform a clean-up of the effective configuration:switch:admin> fcoelogincfg --purge -
310 Fabric OS Command Reference53-1003108-01fcoeLoginGroup2fcoeLoginGroupCreates and manages FCoE login group configuration. SYNOPSIS fcoelogingroup -
Fabric OS Command Reference 31153-1003108-01fcoeLoginGroup2lgnameSpecifies the name of the login group.--addAdds VN_Port devices to the login group.lg
6 Fabric OS Command Reference53-1003108-01Determining RBAC permissions for a specific command1
312 Fabric OS Command Reference53-1003108-01fcPing2fcPingSends a Fibre Channel Extended Link Service (ELS) Echo request to a pair of ports or to a sin
Fabric OS Command Reference 31353-1003108-01fcPing2Logical Fabrics: When executed in a Logical Fabric from a switch to a destination device connected
314 Fabric OS Command Reference53-1003108-01fcPing2--bypasszoneBypasses the zone check.--quietSuppresses the diagnostic output. Only zoning informatio
Fabric OS Command Reference 31553-1003108-01fcPing2EXAMPLES To display one device that accepts the request and another device that rejects the request
316 Fabric OS Command Reference53-1003108-01fcPing2 Request rejected by 0x022300: Command not supported: time: 1038 usec Request rejected by 0x022300:
Fabric OS Command Reference 31753-1003108-01fcPing2received reply from 20:00:00:00:c9:3f:7c:b8:12 bytes time:714 usecreceived reply from 20:00:00:00:c
318 Fabric OS Command Reference53-1003108-01fcPing2(101/8 ,101/EMB)[128] FAILED(101/3 ,101/EMB)[128] FAILED4(101/3 ,101/EMB)[128] FAILED 101/8
Fabric OS Command Reference 31953-1003108-01fcPing2INTERNAL PORT COVERAGE-----------------------SNO DOMAIN INTRNL_PORT STATUS----------------
320 Fabric OS Command Reference53-1003108-01fcpLogClear2fcpLogClearClears the FCPD debug information log. SYNOPSIS fcplogclearDESCRIPTION Use this com
Fabric OS Command Reference 32153-1003108-01fcpLogDisable2fcpLogDisableDisables the FCPD debug information log. SYNOPSIS fcplogdisableDESCRIPTION Use
Fabric OS Command Reference 753-1003108-01Chapter2Fabric OS CommandsaaaConfigManages RADIUS, LDAP, and TACACS+ configuration information. SYNOPSIS aaa
322 Fabric OS Command Reference53-1003108-01fcpLogEnable2fcpLogEnableEnables the FCPD debug information log. SYNOPSIS fcplogenableDESCRIPTION Use this
Fabric OS Command Reference 32353-1003108-01fcpLogShow2fcpLogShowDisplays the FCPD debug information log. SYNOPSIS fcplogshowDESCRIPTION Use this comm
324 Fabric OS Command Reference53-1003108-01fcpProbeShow2fcpProbeShowDisplays the Fibre Channel Protocol (FCP) probe information. SYNOPSIS fcpprobesho
Fabric OS Command Reference 32553-1003108-01fcpRlsProbe2fcpRlsProbeInitiates the Fibre Channel Protocol (FCP) Read Link Status (RLS) probing for F_Por
326 Fabric OS Command Reference53-1003108-01fcpRlsProbe2Last Updated : Fri May 18 08:44:11 2012-------------------------------------------------
Fabric OS Command Reference 32753-1003108-01fcpRlsShow2fcpRlsShowDisplays the Fibre Channel Protocol (FCP) Read Link Status (RLS) information. SYNOPSI
328 Fabric OS Command Reference53-1003108-01fcpRlsShow2Last Updated : Mar 4 03:17:52 2012-----------------------------------------------------
Fabric OS Command Reference 32953-1003108-01fcrBcastConfig2fcrBcastConfigDisplays or sets the broadcast frame forwarding option. SYNOPSIS fcrbcastconf
330 Fabric OS Command Reference53-1003108-01fcrBcastConfig2To display the new configuration:switch:admin> fcrbcastconfig --showBroadcast configurat
Fabric OS Command Reference 33153-1003108-01fcrConfigure2fcrConfigureDisplays or sets FC Router configuration parameters. SYNOPSIS fcrconfigure --bbfi
8 Fabric OS Command Reference53-1003108-01aaaConfig2The execution of this command is subject to Virtual Fabric or Admin Domain restrictions that may b
332 Fabric OS Command Reference53-1003108-01fcrConfigure2After you identify the FCIP links between FC Routers for all fabrics and updated the cost of
Fabric OS Command Reference 33353-1003108-01fcrEdgeShow2fcrEdgeShowDisplays the FIDs of all configured EX_Ports. SYNOPSIS fcredgeshowfcredgeshow [-fid
334 Fabric OS Command Reference53-1003108-01fcrEdgeShow2EXAMPLES To display the EX_Ports configured in the switch:switch:admin> fcredgeshowFID EX
Fabric OS Command Reference 33553-1003108-01fcrFabricShow2fcrFabricShowDisplays the FC Routers on a backbone fabric.SYNOPSIS fcrfabricshowfcrfabricsho
336 Fabric OS Command Reference53-1003108-01fcrFabricShow2EXAMPLES To display the FC Routers in the backbone fabric:switch:admin> fcrfabricshowFC R
Fabric OS Command Reference 33753-1003108-01fcrIclPathBWMonitor2fcrIclPathBWMonitorSets or displays FC Router ICL bandwidth monitor parameters for EX_
338 Fabric OS Command Reference53-1003108-01fcrIclPathBWMonitor2To display the current configuration:fcr:admin> fcriclpathbwmonitor --showICL Path
Fabric OS Command Reference 33953-1003108-01fcrLsan2fcrLsanConfigures and displays LSAN policies. SYNOPSIS fcrlsanfcrlsan --add -enforce tag | -speed
340 Fabric OS Command Reference53-1003108-01fcrLsan2--showDisplays the specified tag from the LSAN tag configuration. --helpDisplays the command usage
Fabric OS Command Reference 34153-1003108-01fcrLsanCount2fcrLsanCountDisplays or sets the maximum LSAN count. SYNOPSIS fcrlsancount [max_lsan_count] D
Fabric OS Command Reference 953-1003108-01aaaConfig2Note that the distinction between protocols is only applicable to the packets between a system and
342 Fabric OS Command Reference53-1003108-01fcrLsanMatrix2fcrLsanMatrixCreates, modifies, and displays the LSAN fabric matrix or the FCR matrix.SYNOPS
Fabric OS Command Reference 34353-1003108-01fcrLsanMatrix2NOTES The execution of this command is subject to Virtual Fabric or Admin Domain restriction
344 Fabric OS Command Reference53-1003108-01fcrLsanMatrix2To zero out the database, execute the following commands: - fcrlsanmatrix --add -lsan 0 0 -
Fabric OS Command Reference 34553-1003108-01fcrLsanMatrix2To view the persistent changes: switch:admin> fcrlsanmatrix -lsanLSAN MATRIX is activated
346 Fabric OS Command Reference53-1003108-01fcrLsanMatrix2To view all the static and the default/dynamic fabric binding in the backbone: switch:admin&
Fabric OS Command Reference 34753-1003108-01fcrPhyDevShow2fcrPhyDevShowDisplays the FC Router physical device information. SYNOPSIS fcrphydevshow [-a]
348 Fabric OS Command Reference53-1003108-01fcrPhyDevShow2local failurethe number of times the device login failed because of missing LSAN zones withi
Fabric OS Command Reference 34953-1003108-01fcrProxyConfig2fcrProxyConfigDisplays or configures proxy devices presented by an FC Router. SYNOPSIS fcrp
350 Fabric OS Command Reference53-1003108-01fcrProxyConfig2If no proxy device WWN is stored in any slot for all edge fabrics, the following message is
Fabric OS Command Reference 35153-1003108-01fcrProxyDevShow2fcrProxyDevShowDisplays FC Router proxy device information. SYNOPSIS fcrproxydevshow [-a][
10 Fabric OS Command Reference53-1003108-01aaaConfig2"ldap"When "ldap" is specified, the first Active directory (AD) server is con
352 Fabric OS Command Reference53-1003108-01fcrProxyDevShow2-a -f fabricidDisplay the proxy devices in the specified fabric for all FC Routers in the
Fabric OS Command Reference 35353-1003108-01fcrResourceShow2fcrResourceShowDisplays FC Router physical resource usage. SYNOPSIS fcrresourceshowDESCRIP
354 Fabric OS Command Reference53-1003108-01fcrResourceShow2OPERANDS NoneEXAMPLES To display the resource usage for the local FC Router:switch:admin&g
Fabric OS Command Reference 35553-1003108-01fcrRouterPortCost2fcrRouterPortCostDisplays or sets an FC Router port cost. SYNOPSIS fcrrouterportcost [[s
356 Fabric OS Command Reference53-1003108-01fcrRouterPortCost2To display the cost on an EX_Port:switch:admin> fcrrouterportcost 7/10 0switch:admin&
Fabric OS Command Reference 35753-1003108-01fcrRouteShow2fcrRouteShowDisplays FC Router route information. SYNOPSIS fcrrouteshowDESCRIPTION Use this c
358 Fabric OS Command Reference53-1003108-01fcrXlateConfig2fcrXlateConfigConfigures a translate (xlate) domain's domain ID and state of persisten
Fabric OS Command Reference 35953-1003108-01fcrXlateConfig2NOTES The execution of this command is subject to Virtual Fabric or Admin Domain restrictio
360 Fabric OS Command Reference53-1003108-01fcrXlateConfig2--show stalexd [importedFID]Displays stale translate domains associated with the specified
Fabric OS Command Reference 36153-1003108-01fddCfg2fddCfgManages the fabric data distribution configuration parameters. SYNOPSIS fddcfg --showallfddcf
Fabric OS Command Reference 1153-1003108-01aaaConfig2LDAP CONFIGURATIONS===================LDAP configuration does not exist. TACACS+ CONFIGURATIONS==
362 Fabric OS Command Reference53-1003108-01fddCfg2--localreject policy_listConfigures the switch to reject distributions of the specified policies in
Fabric OS Command Reference 36353-1003108-01fdmiCacheShow2fdmiCacheShowDisplays abbreviated remote FDMI device information, according to remote domain
364 Fabric OS Command Reference53-1003108-01fdmiShow2fdmiShowDisplays detailed FDMI information.SYNOPSIS fdmishowDESCRIPTION Use this command to displ
Fabric OS Command Reference 36553-1003108-01fdmiShow2 Number of Ports: 2 Fabric Name: 10:00:00:05:1e:e5:e8:00 Bios Version: 3.2.0.0_alpha_bld
366 Fabric OS Command Reference53-1003108-01ficonCfg2ficonCfgConfigures the specified FICON database. SYNOPSIS ficoncfg --set database portficoncfg --
Fabric OS Command Reference 36753-1003108-01ficonClear2ficonClearClears the records from the specified FICON database. SYNOPSIS ficonclear databaseDES
368 Fabric OS Command Reference53-1003108-01ficonCupSet2ficonCupSetSets FICON-CUP parameters for a switch. SYNOPSIS ficoncupset fmsmode enable | disab
Fabric OS Command Reference 36953-1003108-01ficonCupSet2HCPHost control prohibitedMIHPTOSets the missing interrupt handler primary timeout (MIHPTO) va
370 Fabric OS Command Reference53-1003108-01ficonCupSet2082300 1C Oper082400 1A Reset082400 1B Reset612400 1E Reset Prim
Fabric OS Command Reference 37153-1003108-01ficonCupShow2ficonCupShowDisplays FICON-CUP parameters for a switch. SYNOPSIS ficoncupshow fmsmodeficoncup
Fabric OS Command Reference 53-1001186-01 Added 14 new commands to support Logical Fabrics. Modified 63 commands with new command operands to suppor
12 Fabric OS Command Reference53-1003108-01aaaConfig2To add a TACACS+ server to the configuration:switch:admin> aaaconfig --add 10.17.56.56 -conf t
372 Fabric OS Command Reference53-1003108-01ficonCupShow2MIHPTODisplays the FICON-CUP missing interrupt handler primary timeout (MIHPTO) value in seco
Fabric OS Command Reference 37353-1003108-01ficonCupShow2 082300 1C Oper 082400 1A Reset 082400 1B Reset 612400 1E Reset
374 Fabric OS Command Reference53-1003108-01ficonHelp2ficonHelpDisplays a list of FICON support commands. SYNOPSIS ficonhelpDESCRIPTION Use this comma
Fabric OS Command Reference 37553-1003108-01ficonShow2ficonShowDisplays the contents of the specified FICON database. SYNOPSIS ficonshow database [fab
376 Fabric OS Command Reference53-1003108-01ficonShow2Incident CountDisplays the incident count. This number increases by 1 for each incident within t
Fabric OS Command Reference 37753-1003108-01ficonShow20x40Other FC-4s including FCP and updates.0x60FC-SB-2 and updates and other FC-4s including FCP
378 Fabric OS Command Reference53-1003108-01ficonShow20xIDCHIPID if channel port has registered with the switch.0xPNIf switch has registered with the
Fabric OS Command Reference 37953-1003108-01ficonShow2Time StampDisplays the timestamp, expressed in date format.TypeSame as Port Type.Type NumberDisp
380 Fabric OS Command Reference53-1003108-01ficonShow2EXAMPLES To display the local RNID database: switch:admin> ficonshow RNID{ {Fmt Type PID Regi
Fabric OS Command Reference 38153-1003108-01ficonShow2To display RNID data for the specified port:switch:admin> ficonshow RNID port 0x08{Fmt Type
Fabric OS Command Reference 1353-1003108-01ad2adManages Admin Domain operations. SYNOPSIS ad --activate ad_idad --add ad_id [-d "dev_list"]
382 Fabric OS Command Reference53-1003108-01ficonShow2To display the local Switch RNID database: switch:admin> ficonshow switchrnid{ {Switch WWN
Fabric OS Command Reference 38353-1003108-01fipsCfg2fipsCfgConfigures FIPS (Federal Information Processing Standards) mode. SYNOPSIS fipscfg --enable
384 Fabric OS Command Reference53-1003108-01fipsCfg2--zeroize [-nowarn]Erases all passwords, shared secrets, private keys, etc. in the system. --show
Fabric OS Command Reference 38553-1003108-01fipsCfg2Bootprom access is enabled - FAILFirmwaredownload signature verification is disabled - FAILSecur
386 Fabric OS Command Reference53-1003108-01fipsCfg2To back out of a zeroizing operation:switch:admin> fipscfg --zeroizeYou are Zeroizing FIPS conf
Fabric OS Command Reference 38753-1003108-01fipsCfg2To disable bootprom:switch:root> fipscfg --disable bootprom You are disabling bootprom.Do you w
388 Fabric OS Command Reference53-1003108-01firmwareCommit2firmwareCommitCommits switch firmware. SYNOPSIS firmwarecommitDESCRIPTION Use this command
Fabric OS Command Reference 38953-1003108-01firmwareDownload2firmwareDownloadDownloads firmware from a remote host, a local directory, or a USB device
390 Fabric OS Command Reference53-1003108-01firmwareDownload2All systems supported by this firmware have two partitions of nonvolatile storage (primar
Fabric OS Command Reference 39153-1003108-01firmwareDownload2-nDisables autocommit mode. When autocommit mode is disabled, the firmwareCommit command
14 Fabric OS Command Reference53-1003108-01ad2Before creating Admin Domains, the default zone mode should be set to "No Access". To set the
392 Fabric OS Command Reference53-1003108-01firmwareDownload2-eRemoves all of the installed SA images in the system during SAS firmware download. By d
Fabric OS Command Reference 39353-1003108-01firmwareDownload2To download firmware interactively:switch:admin> firmwaredownloadServer Name or IP Add
394 Fabric OS Command Reference53-1003108-01firmwareDownloadStatus2firmwareDownloadStatusDisplays the status of a firmware download. SYNOPSIS firmware
Fabric OS Command Reference 39553-1003108-01firmwareDownloadStatus2[5]: Fri Mar 25 16:58:44 2011Slot 7 (CP1, standby): Firmware commit operation has s
396 Fabric OS Command Reference53-1003108-01firmwareKeyShow2firmwareKeyShowDisplays the public key used for signed firmware validation. SYNOPSIS firmw
Fabric OS Command Reference 39753-1003108-01firmwareRestore2firmwareRestoreRestores the former active firmware image. SYNOPSIS firmwarerestoreDESCRIPT
398 Fabric OS Command Reference53-1003108-01firmwareShow2firmwareShowDisplays the firmware version and download history. SYNOPSIS firmwareshowfirmware
Fabric OS Command Reference 39953-1003108-01firmwareShow2To display the firmware download history:switch:admin> firmwareshow --historyFirmware vers
400 Fabric OS Command Reference53-1003108-01flow2flowCreates, manages, and displays flows in Flow Vision. SYNOPSIS flow --create flow_name -feature fe
Fabric OS Command Reference 40153-1003108-01flow2FUNCTION Creating a flow SYNOPSIS flow --create flow_name -feature feature_list port_options fram
Fabric OS Command Reference 1553-1003108-01ad2--create argumentsCreates a new Admin Domain with optionally specified device or switch members. A newly
402 Fabric OS Command Reference53-1003108-01flow2• You can use WWN or Fibre Channel ID (FCID) for the -srcdev and -dstdev operands when creating Flow
Fabric OS Command Reference 40353-1003108-01flow2-egrport portSpecifies the egress port. The port can be in either [slot/]port or D,I format depending
404 Fabric OS Command Reference53-1003108-01flow2EXAMPLES To create a flow on ingress port (1/10) for traffic from the source device (0x020a00) to the
Fabric OS Command Reference 40553-1003108-01flow2DESCRIPTION Use this command to activate a flow if it is not in the active state or configure the spe
406 Fabric OS Command Reference53-1003108-01flow2DESCRIPTION Use this command to modify the port or device addressing mode and to change the control p
Fabric OS Command Reference 40753-1003108-01flow2-disable_wrapDisables the wrapping of mirrored frame logs. The Flow Mirror flow must be deactivated b
408 Fabric OS Command Reference53-1003108-01flow2DESCRIPTION Displays the flow definitions and frame statistics. When used without operand, the --show
Fabric OS Command Reference 40953-1003108-01flow2-frametype typeSpecifies the predefined frame type. Valid values for type include the following: SCSI
410 Fabric OS Command Reference53-1003108-01flow2To display the flow definition and statistics of a flow:switch:admin> flow --show myflow2=========
Fabric OS Command Reference 41153-1003108-01flow2 | Reads / Writes/ Total | ------------------------- | 2.62M/ 2.62M/ 5.25M | ------
16 Fabric OS Command Reference53-1003108-01ad2--show argumentsDisplays the membership information of the specified Admin Domain or all Admin Domains.W
412 Fabric OS Command Reference53-1003108-01flow2 | 444.62M | 1052 | | 314.17M | 452 |
Fabric OS Command Reference 41353-1003108-01flow2Flow Monitor:---------------------------------------------------------------- \|SID(*)| Tx Frames Cou
414 Fabric OS Command Reference53-1003108-01flow2DESCRIPTION Use this command to delete the specified flow from Flow Vision. All the data associated w
Fabric OS Command Reference 41553-1003108-01flow2<Frame options> -srcdev <devID> : FC device that is flow source (SID or PWWN) -dstdev
416 Fabric OS Command Reference53-1003108-01fmMonitor2fmMonitorManages frame monitor configuration. SYNOPSIS fmmonitor --create frame_type -pat bit_pa
Fabric OS Command Reference 41753-1003108-01fmMonitor2This command requires an Advanced Performance Monitoring license. A Fabric Watch license is opti
418 Fabric OS Command Reference53-1003108-01fmMonitor2SCSI3_RESERVESpecifies a frame of type SCSI-3 Reserve with a bit pattern of "12,0xFF,0x08;4
Fabric OS Command Reference 41953-1003108-01fmMonitor2-port port_listSpecifies one or more ports on which to install the monitor for the specified fra
420 Fabric OS Command Reference53-1003108-01fmMonitor2--delete frame_typeDeletes an existing frame type. This command removes the entire configuration
Fabric OS Command Reference 42153-1003108-01fmMonitor2To install a SCSI frame monitor on ports 3-12: switch:admin> fmmonitor --addmonitor SCSI -por
Fabric OS Command Reference 1753-1003108-01ad2-d "dev_list"Specifies the list of devices in an Admin Domain, in quotation marks. Separate ea
422 Fabric OS Command Reference53-1003108-01fmMonitor2 -|scsi2reserve|N/A |0 |None |None |N/A -|scsi3reserve|N/A |0 |N
Fabric OS Command Reference 42353-1003108-01fosConfig2fosConfigDisplays or modifies Fabric OS features. SYNOPSIS fosconfig --enable featurefosconfig -
424 Fabric OS Command Reference53-1003108-01fosConfig2ethswEnables the Ethernet switch service on the switch. The Ethernet switch service is disabled
Fabric OS Command Reference 42553-1003108-01fosConfig2To enable Virtual Fabrics:switch:admin> fosconfig --enable vfWARNING: This is a disruptive o
426 Fabric OS Command Reference53-1003108-01fosExec2fosExecExecutes a command in a specified logical switch context. SYNOPSIS fosexec --fid FID -cmd &
Fabric OS Command Reference 42753-1003108-01fosExec2 Default Switch: No, Address Mode 0]Index Slot Port Address Media Speed State Proto=========
428 Fabric OS Command Reference53-1003108-01fosExec2To display the switch name for all logical switches without confirmation:switch:user> fosexec -
Fabric OS Command Reference 42953-1003108-01frameLog2frameLogDisplays information about discarded frames. SYNOPSIS framelog --disableframelog --enable
430 Fabric OS Command Reference53-1003108-01frameLog2TypeReason for the frame discard. Frames can be discarded for a variety of reasons. The only disc
Fabric OS Command Reference 43153-1003108-01frameLog2--showPrints a listing of details about stored frames that match the specified filter criteria. T
18 Fabric OS Command Reference53-1003108-01ad21Displays the Admin Domain configuration stored in persistent memory (defined configuration).2Displays t
432 Fabric OS Command Reference53-1003108-01frameLog2timestamp port port SID DID SFID DFID Type Count============================
Fabric OS Command Reference 43353-1003108-01fspfShow2fspfShowDisplays Fabric Shortest Path First (FSPF) protocol information. SYNOPSIS fspfshowDESCRIP
434 Fabric OS Command Reference53-1003108-01fspfShow2lsrDelayToLink State Record delay time out value in milliseconds.lsrDelayCountCounter of delayed
Fabric OS Command Reference 43553-1003108-01fspfShow2f_ports[9] = 0x00000000f_ports[10] = 0x00000000f_ports[11] = 0x00000000f_ports[12]
436 Fabric OS Command Reference53-1003108-01fwAlarmsFilterSet2fwAlarmsFilterSetEnables or disables alarms for Fabric Watch. SYNOPSIS fwalarmsfilterset
Fabric OS Command Reference 43753-1003108-01fwAlarmsFilterShow2fwAlarmsFilterShowDisplays alarm filtering for Fabric Watch. SYNOPSIS fwalarmsfiltersho
438 Fabric OS Command Reference53-1003108-01fwClassInit2fwClassInitInitializes all classes under Fabric Watch. SYNOPSIS fwclassinitDESCRIPTION Use thi
Fabric OS Command Reference 43953-1003108-01fwConfigReload2fwConfigReloadReloads the Fabric Watch configuration. SYNOPSIS fwconfigreloadDESCRIPTION Us
440 Fabric OS Command Reference53-1003108-01fwFruCfg2fwFruCfgDisplays or modifies FRU state alert configuration. SYNOPSIS fwfrucfg [--show]DESCRIPTION
Fabric OS Command Reference 44153-1003108-01fwFruCfg2WWN Alarm State: (0..31) [1]WWN Alarm Action: (0..17) [1]SFP Alarm State: (0..19) [0]SFP Alarm Ac
Fabric OS Command Reference 1953-1003108-01ad2To deactivate Admin Domain 5:switch:admin> ad --deactivate 5You are about to deactivate an AD.This op
442 Fabric OS Command Reference53-1003108-01fwHelp2fwHelpDisplays Fabric Watch command information. SYNOPSIS fwhelpDESCRIPTION Use this command to dis
Fabric OS Command Reference 44353-1003108-01fwMailCfg2fwMailCfgDisplays and configures Fabric Watch email alerts. SYNOPSIS fwmailcfgDESCRIPTION Use th
444 Fabric OS Command Reference53-1003108-01fwMailCfg2 9 : Filter Performance Monitor class 10 : Security class 11 : Resource Monitor cla
Fabric OS Command Reference 44553-1003108-01fwMailCfg2 4 : F/FL Port (Optical) class 5 : Resource class 6 : quit Select a class => :
446 Fabric OS Command Reference53-1003108-01fwPortDetailShow2fwPortDetailShowDisplays the port information for specified user ports. SYNOPSIS fwportde
Fabric OS Command Reference 44753-1003108-01fwPortDetailShow2When used without operands, this command displays information for all ports.NOTES This co
448 Fabric OS Command Reference53-1003108-01fwPortDetailShow2To retrieve a port detail report for all ports in healthy state:switch:user> fwportdet
Fabric OS Command Reference 44953-1003108-01fwSamShow2fwSamShowGenerates switch availability monitor (SAM) report. SYNOPSIS fwsamshowDESCRIPTION Use t
450 Fabric OS Command Reference53-1003108-01fwSet2fwSetSets port persistence time. SYNOPSIS fwset --port --persistence secondsDESCRIPTION Use this com
Fabric OS Command Reference 45153-1003108-01fwSetToCustom2fwSetToCustomSets Fabric Watch thresholds and alarm levels to custom values. SYNOPSIS fwsett
20 Fabric OS Command Reference53-1003108-01ad2To display all ADs:switch:admin> ad --showCurrent AD: 255 : AD255Transaction buffer configuration:---
452 Fabric OS Command Reference53-1003108-01fwSetToCustom2 Trigger : Above Action: None Trigger : Below Action: Raslog,SNMP
Fabric OS Command Reference 45353-1003108-01fwSetToDefault2fwSetToDefaultReturns Fabric Watch thresholds and alarm levels to default values. SYNOPSIS
454 Fabric OS Command Reference53-1003108-01fwSetToDefault2 Value : 0 Trigger : Above Action: None Trigger :
Fabric OS Command Reference 45553-1003108-01gePortErrShow2gePortErrShowDisplays error statistics of Gigabit Ethernet (GbE) port and XGE ports.SYNOPSIS
456 Fabric OS Command Reference53-1003108-01h2hDisplays shell history. SYNOPSIS hhistoryDESCRIPTION Use this command to view the shell history. The sh
Fabric OS Command Reference 45753-1003108-01haDisable2haDisableDisables the High Availability feature. SYNOPSIS hadisableDESCRIPTION Use this command
458 Fabric OS Command Reference53-1003108-01haDump2haDumpDisplays High Availability status information. SYNOPSIS hadumpDESCRIPTION Use this command to
Fabric OS Command Reference 45953-1003108-01haDump2NOTES The execution of this command is subject to Virtual Fabric or Admin Domain restrictions that
460 Fabric OS Command Reference53-1003108-01haEnable2haEnableEnables the High Availability feature. SYNOPSIS haenableDESCRIPTION Use this command to e
Fabric OS Command Reference 46153-1003108-01haFailover2haFailoverForces the failover mechanism so that the standby control processor (CP) becomes the
Fabric OS Command Reference 2153-1003108-01ad2To display the Admin Domain effective configuration information:switch:admin> ad --show -m 2Current A
462 Fabric OS Command Reference53-1003108-01haShow2haShowDisplays control processor (CP) status. SYNOPSIS hashowDESCRIPTION Use this command to displa
Fabric OS Command Reference 46353-1003108-01haShow2OPERANDS NoneEXAMPLES To display CP status on a Brocade DCX 8510-8 with a healthy standby CP:switch
464 Fabric OS Command Reference53-1003108-01haSyncStart2haSyncStartEnables High Availability state synchronization. SYNOPSIS hasyncstartDESCRIPTION Us
Fabric OS Command Reference 46553-1003108-01haSyncStop2haSyncStopDisables High Availability state synchronization. SYNOPSIS hasyncstopDESCRIPTION Use
466 Fabric OS Command Reference53-1003108-01help2helpDisplays command help information. SYNOPSIS help [command]help [-p | -page]help --helpDESCRIPTION
Fabric OS Command Reference 46753-1003108-01help2 Tuning policyauditcfg Modifies and displays audit log filter
468 Fabric OS Command Reference53-1003108-01historyLastShow2historyLastShowDisplays the latest entry in the field replaceable unit (FRU) history log.
Fabric OS Command Reference 46953-1003108-01historyMode2historyModeDisplays the mode of the field replaceable unit (FRU) history log. SYNOPSIS history
470 Fabric OS Command Reference53-1003108-01historyShow2historyShowDisplays the entire field replaceable unit (FRU) history log. SYNOPSIS historyshowD
Fabric OS Command Reference 47153-1003108-01historyShow2FAN Unit 3 Inserted at Tue Aug 14 10:23:45 2001Factory Part Number: 20-123456-
Fabric OS Command Reference 53-1002447-01 Added 2 new commands. Modified 19 commands to support Fabric OS v7.0.1 features. Removed 1 command. Updated
22 Fabric OS Command Reference53-1003108-01ad2 1,337;----------------------------* - Member does not exist+ - Member is AD
472 Fabric OS Command Reference53-1003108-01i2iDisplays a process summary. SYNOPSIS i [processID]DESCRIPTION Use this command to display information a
Fabric OS Command Reference 47353-1003108-01i2CProcessor utilization for schedulingPRIPriority number of the process; higher numbers mean lower priori
474 Fabric OS Command Reference53-1003108-01iclCfg2iclCfgEnables or disables Inter-chassis links (ICL). SYNOPSIS iclcfg --enable slot/icl_groupiclcfg
Fabric OS Command Reference 47553-1003108-01iclCfg2To disable the ICL for ports 16-31 persistently:switch:user> iclcfg --persistentdisable 8/1To en
476 Fabric OS Command Reference53-1003108-01ifModeSet2ifModeSetSets the link operating mode for a network interface. SYNOPSIS ifmodeset ["interfa
Fabric OS Command Reference 47753-1003108-01ifModeSet2--helpDisplays the command usage.EXAMPLES To advertise all modes of operation, when not entering
478 Fabric OS Command Reference53-1003108-01ifModeShow2ifModeShowDisplays the link operating mode and MAC address for a network interface. SYNOPSIS if
Fabric OS Command Reference 47953-1003108-01ifModeShow2To display the active interface:ras010:root> ifmodeshow bond0Currently Active Slave: eth0SEE
480 Fabric OS Command Reference53-1003108-01iflShow2iflShowDisplays the interfabric link (IFL) information.SYNOPSIS iflshowiflshow --helpDESCRIPTION U
Fabric OS Command Reference 48153-1003108-01iflShow2EXAMPLES To display the interfabric links:switch:admin> iflshow E- EX- FCR WWN
Fabric OS Command Reference 2353-1003108-01ag2agEnables Access Gateway (AG) and manages AG-specific operations. SYNOPSIS ag --helpag --showag --modesh
482 Fabric OS Command Reference53-1003108-01interfaceShow2interfaceShowDisplays FSPF interface information. SYNOPSIS interfaceshow [slot/][port]DESCRI
Fabric OS Command Reference 48353-1003108-01interfaceShow2lastScnTimeTime the last State Change Notification was received on this interface.upCountNum
484 Fabric OS Command Reference53-1003108-01interfaceShow2helloTIDHello timer ID.dbRtxTIDDatabase retransmission timer ID.lsrRtxTIDLSR retransmission
Fabric OS Command Reference 48553-1003108-01interfaceShow2stateSubstate of the port. The port can be in one of the following 12 substates:INIT (0)The
486 Fabric OS Command Reference53-1003108-01interfaceShow2decom_trunk_memberIndicates if decommissioning request is for a multi-link trunk.NOTES The e
Fabric OS Command Reference 48753-1003108-01interfaceShow2nbstFull = Jan 01 00:00:00.000&dbRetransList = 0x10b96928&lsrRetransList = 0
488 Fabric OS Command Reference53-1003108-01iodReset2iodResetDisables in-order delivery (IOD) on a switch. SYNOPSIS iodresetDESCRIPTION Use this comma
Fabric OS Command Reference 48953-1003108-01iodSet2iodSetEnables in-order delivery (IOD). SYNOPSIS iodsetiodset --helpDESCRIPTION Use this command to
490 Fabric OS Command Reference53-1003108-01iodShow2iodShowDisplays the in-order delivery (IOD) setting. SYNOPSIS iodshowDESCRIPTION Use this command
Fabric OS Command Reference 49153-1003108-01ipAddrSet2ipAddrSetSets the Ethernet and FC IP addresses. SYNOPSIS ipaddrset [-ipv6 ] [--add x:x:x:x:x:x:x
24 Fabric OS Command Reference53-1003108-01ag2ag --printalpamap F_Portag --deletepwwnfromdb PWWNag --clearalpamap F_Portag --addwwnmapping N_Port &quo
492 Fabric OS Command Reference53-1003108-01ipAddrSet2• The command accepts the -ipv6 command line syntax with the --add or --delete option on all pla
Fabric OS Command Reference 49353-1003108-01ipAddrSet2-cp cp_numberSpecifies the CP on a chassis. Valid values are 0 or 1. -chassisSpecifies the IPv6
494 Fabric OS Command Reference53-1003108-01ipAddrSet21Sets the Ethernet IP address, Ethernet subnet mask, gateway IP address and host name of CP1.-ch
Fabric OS Command Reference 49553-1003108-01ipAddrSet2To verify the IPv4 FC address for the logical switch:switch:admin> ipaddrshowCHASSISEthernet
496 Fabric OS Command Reference53-1003108-01ipAddrSet2To enable DHCPv6 on a device:switch:admin> ipaddrset -ipv6 -dhcpv6To clear all IP address inf
Fabric OS Command Reference 49753-1003108-01ipAddrShow2ipAddrShowDisplays IP address information for a switch or control processor (CP). SYNOPSIS ipad
498 Fabric OS Command Reference53-1003108-01ipAddrShow2- tentative- preferred- deprecatedRefer to the RFC 2462 specification for more information.On m
Fabric OS Command Reference 49953-1003108-01ipAddrShow2Ethernet Subnetmask: 255.255.240.0Host Name: cp1Gateway IP Address: 10.33.48.1Backplane IP addr
500 Fabric OS Command Reference53-1003108-01ipFilter2ipFilterManages the IP filter policies. SYNOPSIS ipfilter --create policyname -type ipv4 | ipv6ip
Fabric OS Command Reference 50153-1003108-01ipFilter2OPERANDS This command has the following operands:policynameSpecifies an IP filter policy name. T
Fabric OS Command Reference 2553-1003108-01ag2• Manage device WWN to N_Port group mappings.• Manage device WWN failover to N_Ports configured as prefe
502 Fabric OS Command Reference53-1003108-01ipFilter2The following arguments are supported with the --addrule option:-sip source_IPSpecifies the sourc
Fabric OS Command Reference 50353-1003108-01ipFilter2EXAMPLES To create an IP filter for a policy with an IPv6 address:switch:admin> ipfilter --cr
504 Fabric OS Command Reference53-1003108-01ipFilter24 any tcp 443 permit5 any udp 161
Fabric OS Command Reference 50553-1003108-01ipFilter2To add a rule for traffic of type FORWARD and to display the result:switch:admin> ipfilter --a
506 Fabric OS Command Reference53-1003108-01ipSecConfig2ipSecConfigConfigures Internet Protocol security (IPSec) policies for Ethernet management inte
Fabric OS Command Reference 50753-1003108-01ipSecConfig2• Flush existing SAs from the kernel SA database (SADB).• Display policy parameters.Representa
508 Fabric OS Command Reference53-1003108-01ipSecConfig2typeSpecifies the policy to be created. Supported policies include the following:policy ipsCre
Fabric OS Command Reference 50953-1003108-01ipSecConfig2-mode tunnel | transport Specifies the IPSec transform mode. In tunnel mode, the IP datagram i
510 Fabric OS Command Reference53-1003108-01ipSecConfig2-tag name Specifies a name for the SA. This is a user-generated name. The name must be between
Fabric OS Command Reference 51153-1003108-01ipSecConfig2-id identifierSpecifies the local identifier. The switch is identified by its IPv4 or IPv6 add
26 Fabric OS Command Reference53-1003108-01ag2--modedisableDisables Access Gateway mode on a switch. After AG mode is disabled, the switch reboots aut
512 Fabric OS Command Reference53-1003108-01ipSecConfig2The following operands are optional (use secCertUtil to import the key files to the local and
Fabric OS Command Reference 51353-1003108-01ipSecConfig2-ipsec ah | espSpecifies the IPSec protocol. Encapsulating Security Payload (ESP) provides con
514 Fabric OS Command Reference53-1003108-01ipSecConfig2--deleteDeletes a specified policy or all policies of a certain typefrom the configuration dat
Fabric OS Command Reference 51553-1003108-01ipSecConfig2typeSpecifies the policy to be displayed. Valid values for type include the following:policy i
516 Fabric OS Command Reference53-1003108-01ipSecConfig22. Create an IPSec SA policy named AH01, which uses AH protection with MD5. switch:admin> i
Fabric OS Command Reference 51753-1003108-01ipSecConfig23. Create an IPSec proposal IPSEC-ESP to use ESP01 as the SA. switch:admin> ipsecconfig --a
518 Fabric OS Command Reference53-1003108-01ipSecConfig2Example 3 The following example illustrates how to secure traffic between two systems using AH
Fabric OS Command Reference 51953-1003108-01ipSecConfig2Example 4 The following example illustrates how to secure traffic between two systems using pr
520 Fabric OS Command Reference53-1003108-01ipSecConfig2 created: Oct 15 23:34:55 2008 current: Oct 15 23:35:06 2008 diff: 11(s) hard: 2621440
Fabric OS Command Reference 52153-1003108-01ipSecConfig2switch:admin> ipsecconfig --help modify policy ike Usage: ipsecConfig --modify policy ike A
Fabric OS Command Reference 2753-1003108-01ag2autoDisables the automatic port configuration policy and deletes all associated configuration settings.
522 Fabric OS Command Reference53-1003108-01islShow2islShowDisplays interswitch link (ISL) information. SYNOPSIS islshowDESCRIPTION Use this command t
Fabric OS Command Reference 52353-1003108-01islShow2To execute islshow in a logical fabric:switch:user> islshow1: 33-> 29 10:00:00:60:69:80:4f:8
524 Fabric OS Command Reference53-1003108-01islShow25: 27->340 10:00:00:05:1e:e5:e4:00 1 D-Port_DCX \ sp: 16.000G bw: 16.000G CR_RECOV FEC6: 28
Fabric OS Command Reference 52553-1003108-01itemList2itemListLists parameter syntax information. SYNOPSIS item_list = element | element white item_lis
526 Fabric OS Command Reference53-1003108-01itemList2within the current switch (selected during Telnet login) are tested. When specified in an item li
Fabric OS Command Reference 52753-1003108-01killTelnet2killTelnetTerminates an open Telnet session. SYNOPSIS killtelnetDESCRIPTION Use this command to
528 Fabric OS Command Reference53-1003108-01ldapCfg2ldapCfgMaps LDAP AD server roles to default switch roles. SYNOPSIS ldapcfg --maprole ldaprole swit
Fabric OS Command Reference 52953-1003108-01ldapCfg2--unmaproleRemoves the mapping between an LDAP role and a switch role. Use the --show option for a
530 Fabric OS Command Reference53-1003108-01lfCfg2lfCfgConfigures and displays logical fabrics. SYNOPSIS lfcfg [--show | --showall] -cfglfcfg [--show
Fabric OS Command Reference 53153-1003108-01lfCfg2PortNumber of the logical LISL port.remote-domainDomain ID of the base switch in the remote chassis.
28 Fabric OS Command Reference53-1003108-01ag2--pgdel pgid "N_Port1 [; N_Port2;...]"Deletes one or more N_Ports from the specified port gro
532 Fabric OS Command Reference53-1003108-01lfCfg2--lislenableRe-enables all LISLs in the fabric that were disabled because of some conflict or error
Fabric OS Command Reference 53353-1003108-01lfCfg2Displays status information about the LISLs in the logical switch set by the context:switch:admin>
534 Fabric OS Command Reference53-1003108-01licenseAdd2licenseAddAdds a license key to a switch. SYNOPSIS licenseadd licenseDESCRIPTION Use this comma
Fabric OS Command Reference 53553-1003108-01licenseIdShow2licenseIdShowDisplays the system license ID. SYNOPSIS licenseidshowDESCRIPTION Use this comm
536 Fabric OS Command Reference53-1003108-01licensePort2licensePortManages Dynamic Ports On Demand (DPOD) licenses. SYNOPSIS licenseport --release por
Fabric OS Command Reference 53753-1003108-01licensePort2EXAMPLES To activate Dynamic Ports On Demand:switch:admin> licenseport --method dynamicThe
538 Fabric OS Command Reference53-1003108-01licensePort2To disable Dynamic Ports On Demand:switch:admin> licenseport --method staticThe POD method
Fabric OS Command Reference 53953-1003108-01licenseRemove2licenseRemoveRemoves or deactivates a license key. SYNOPSIS licenseremove licenseDESCRIPTION
540 Fabric OS Command Reference53-1003108-01licenseShow2licenseShowDisplays current license keys. SYNOPSIS licenseshowDESCRIPTION Use this command to
Fabric OS Command Reference 54153-1003108-01licenseShow2 Fabric Watch licenseRyeSzRScycazfT0G: Trunking licenseRyeSzRScycS0fT09: 4 Domain
Fabric OS Command Reference 2953-1003108-01ag2--pgfnmtov new_tovDisplays the fabric name monitoring timeout value in seconds when used without specify
542 Fabric OS Command Reference53-1003108-01licenseShow2To display an ICL license on a Brocade DCX before and after a firmware upgrade to Fabric OS v7
Fabric OS Command Reference 54353-1003108-01licenseSlotCfg2licenseSlotCfgConfigures and displays slot-based licensed features. SYNOPSIS licenseslotcfg
544 Fabric OS Command Reference53-1003108-01licenseSlotCfg2--showDisplays slot assignments for all slot-based licenses in the chassis.--helpDisplays t
Fabric OS Command Reference 54553-1003108-01licenseSlotCfg2A7N9rATZLYgFa7JBfmGEJKETgCMHFGQMY4gfLmGAa4GA:Advanced FICON Acceleration (FTR_AFA) licenseC
546 Fabric OS Command Reference53-1003108-01licenseSlotCfg2Expiry Date 03/06/2009License is expiredHf7MBEEGCFNmTAWXXF99RtHXQN4RRtM3mLGtrWZLAMaTaAY9EB:
Fabric OS Command Reference 54753-1003108-01linkCost2linkCostSets or displays the Fabric Shortest Path First (FSPF) cost of a link. SYNOPSIS linkcost
548 Fabric OS Command Reference53-1003108-01linkCost21/7 5001/8 5001/9 (E_PORT) 5001/10 5001/11
Fabric OS Command Reference 54953-1003108-01logicalGroup2logicalGroupCreates and manages groups of monitored elements. SYNOPSIS logicalgroup --create
550 Fabric OS Command Reference53-1003108-01logicalGroup2--create group_nameCreates a group of monitored elements.-type group_typeSpecifies the type o
Fabric OS Command Reference 55153-1003108-01logicalGroup2To delete members from a group:switch:admin> logicalgroup --delmember CRITICAL_PORTS -
30 Fabric OS Command Reference53-1003108-01ag2--prefdel "F_Port [;F_Port2;...]" N_PortDeletes the preferred Secondary N_Port for the specifi
552 Fabric OS Command Reference53-1003108-01login2loginLogs in as new user. SYNOPSIS loginDESCRIPTION Use this command to log in to the switch with an
Fabric OS Command Reference 55353-1003108-01logout2logoutLogs out from a shell session. SYNOPSIS logoutDESCRIPTION Use this command to log out from a
554 Fabric OS Command Reference53-1003108-01lsanZoneShow2lsanZoneShowDisplays logical SAN zone information. SYNOPSIS lsanzoneshow [-s] [-f fabricid] [
Fabric OS Command Reference 55553-1003108-01lsanZoneShow2-w wwnDisplays LSAN zones containing the specified port WWN. The WWN format is xx:xx:xx:xx:xx
556 Fabric OS Command Reference53-1003108-01lsCfg2lsCfgConfigures and manages a logical switch SYNOPSIS lscfg --create FID [-b | -base] [-f | -force]l
Fabric OS Command Reference 55753-1003108-01lsCfg2-b | -baseCreates a base logical switch on the chassis. A base logical switch communicates among dif
558 Fabric OS Command Reference53-1003108-01lsCfg2-n | -newfid FIDChanges the fabric ID of an existing logical switch. This command effectively remove
Fabric OS Command Reference 55953-1003108-01lsCfg2Logical Switch has been created with default configurations.Please configure the Logical Switch with
560 Fabric OS Command Reference53-1003108-01lsCfg2To display the logical switch configuration for :FC ports only:switch:admin> lscfg --showCreated
Fabric OS Command Reference 56153-1003108-01lsCfg2 7 | 128 | 2 | | | | | 128 | 128 | 8 | 128 | 2 | | | | | 1
Fabric OS Command Reference 3153-1003108-01ag2--deletepwwnfromdb PWWNRemoves the specified port WWN entry from the database after the host has logged
562 Fabric OS Command Reference53-1003108-01lsDbShow2lsDbShowDisplays the Fabric Shortest Path First (FSPF) link state database. SYNOPSIS lsdbshow [do
Fabric OS Command Reference 56353-1003108-01lsDbShow2mPathCostInternal variable.mHopsFromRootInternal variable.Link State Record pointerPointer to LSR
564 Fabric OS Command Reference53-1003108-01lsDbShow2NOTES The execution of this command is subject to Virtual Fabric or Admin Domain restrictions tha
Fabric OS Command Reference 56553-1003108-01lsDbShow2length = 60chksum = 0x168alinkCnt = 2, flags = 0x0LinkId = 91, out port =
566 Fabric OS Command Reference53-1003108-01mapsConfig2mapsConfigEnables MAPS and sets other MAPS configurations. SYNOPSIS mapsconfig --enablemaps -po
Fabric OS Command Reference 56753-1003108-01mapsConfig2OPERANDS This command has the following operands:--enablemapsEnables MAPS and disables Fabric W
568 Fabric OS Command Reference53-1003108-01mapsConfig2-members member_listSpecifies the specific elements on which to pause or continue monitoring. T
Fabric OS Command Reference 56953-1003108-01mapsConfig2-address email_addressSpecifies the e-mail address to which the notifications are sent. You can
570 Fabric OS Command Reference53-1003108-01mapsConfig2To import a flow:switch:admin> mapsconfig --import fmFlow1To delete all of the user-defined
Fabric OS Command Reference 57153-1003108-01mapsDb2mapsDbDisplays or clears the dashboard showing an at-a-glance snapshot of switch health status. SYN
32 Fabric OS Command Reference53-1003108-01ag2--wwnmappingdisable "WWN [;WWN2;...]" | --allDisables one or more device WWN mappings. Use thi
572 Fabric OS Command Reference53-1003108-01mapsDb2OPERANDS This command has the following operands:--showDisplays a summary of the data collected sin
Fabric OS Command Reference 57353-1003108-01mapsDb2Switch Resource |Out of operating range |In operating range |Traffic Performance |In op
574 Fabric OS Command Reference53-1003108-01mapsDb2To display the dashboard with summary information and historical data for a specific day:switch:adm
Fabric OS Command Reference 57553-1003108-01mapsHelp2mapsHelpDisplays MAPS command information. SYNOPSIS mapshelpDESCRIPTION Use this command to displ
576 Fabric OS Command Reference53-1003108-01mapsPolicy2mapsPolicyCreates and manages MAPS policies. SYNOPSIS mapspolicy --create policy_namemapspolicy
Fabric OS Command Reference 57753-1003108-01mapsPolicy2policy_nameSpecifies the name of the policy to be enabled. The name can be a predefined or a us
578 Fabric OS Command Reference53-1003108-01mapsPolicy2To display a policy:switch:admin> mapspolicy --show Policy1Policy Names Rule Names Action
Fabric OS Command Reference 57953-1003108-01mapsRule2mapsRuleCreates and manages monitoring rules. SYNOPSIS mapsrule --create rule_name -group group_n
580 Fabric OS Command Reference53-1003108-01mapsRule2LFLink failureLOSS_SIGNALLoss of signalPEProtocol errorsLRLink resetC3TXTOClass 3 timeoutsSTATE_C
Fabric OS Command Reference 58153-1003108-01mapsRule2Security violationsMonitors security violations on the switch. Valid values for the security heal
Fabric OS Command Reference 3353-1003108-01ag2Persistent ALPA : DisabledStatic WWN Map : NonePort Group information : PG_ID PG_Members
582 Fabric OS Command Reference53-1003108-01mapsRule2BAD_TEMPTemperature sensors outside rangeBAD_FANAbsent or faulty fansFLASH_USAGEFlash usageMARG_P
Fabric OS Command Reference 58353-1003108-01mapsRule2TX_THPUTTransmit throughputRX_THPUTReceive throughputIO_RDIO read command countIO_WRIO write comm
584 Fabric OS Command Reference53-1003108-01mapsRule2actionSpecifies a comma-separated list of actions to be taken if the specified condition is evalu
Fabric OS Command Reference 58553-1003108-01mapsRule2--config rule_nameModifies a monitoring rule. You cannot modify a default rule. Specify only the
586 Fabric OS Command Reference53-1003108-01mapsRule2To display all of the rules configured on a switch:switch:admin> mapsrule --show -allRASLOG (
Fabric OS Command Reference 58753-1003108-01mapsSam2mapsSamGenerates or clears the port availability monitor report. SYNOPSIS mapssam --showmapssam --
588 Fabric OS Command Reference53-1003108-01mapsSam22 U 0 0 0 1003 F 100 0 0
Fabric OS Command Reference 58953-1003108-01memShow2memShowDisplays the amounts of free and used memory in a switch. SYNOPSIS memshow [-b | -k | -m]DE
590 Fabric OS Command Reference53-1003108-01motd2motdSets the banner on the chassis. SYNOPSIS motd --set stringmotd --showDESCRIPTION Use this command
Fabric OS Command Reference 59153-1003108-01msCapabilityShow2msCapabilityShowDisplays the Management Server (MS) capabilities. SYNOPSIS mscapabilitysh
34 Fabric OS Command Reference53-1003108-01ag2 N-Port F-Port ---------------------------------------------- 0 None 1
592 Fabric OS Command Reference53-1003108-01msConfigure2msConfigureConfigures the Management Server (MS) access control list (ACL). SYNOPSIS msconfigu
Fabric OS Command Reference 59353-1003108-01msConfigure220:02:00:60:69:00:60:150 Done1 Display the access list2 Add member based on
594 Fabric OS Command Reference53-1003108-01msPlatShow2msPlatShowDisplays the Management Server (MS) platform database. SYNOPSIS msplatshowDESCRIPTION
Fabric OS Command Reference 59553-1003108-01msPlatShowDBCB2msPlatShowDBCBDisplays the Management Server (MS) platform service database control block.
596 Fabric OS Command Reference53-1003108-01msPlClearDB2msPlClearDBClears the Management Server (MS) platform database on all switches in the fabric.
Fabric OS Command Reference 59753-1003108-01msPlMgmtActivate2msPlMgmtActivateActivates the Management Server (MS) platform service. SYNOPSIS msplmgmta
598 Fabric OS Command Reference53-1003108-01msPlMgmtDeactivate2msPlMgmtDeactivateDeactivates the Management Server (MS) platform service. SYNOPSIS msp
Fabric OS Command Reference 59953-1003108-01msTdDisable2msTdDisableDisables the Management Server (MS) topology discovery service. SYNOPSIS mstddisabl
600 Fabric OS Command Reference53-1003108-01msTdEnable2msTdEnableEnables the Management Server (MS) topology discovery service. SYNOPSIS mstdenable [&
Fabric OS Command Reference 60153-1003108-01msTdReadConfig2msTdReadConfigDisplays the status of The Management Server (MS) topology discovery service.
Fabric OS Command Reference 3553-1003108-01ag2To disable the ADS policy:switch:admin> ag --policydisable adsTo enable the WWN load balancing policy
602 Fabric OS Command Reference53-1003108-01myId2myIdDisplays the current login session details. SYNOPSIS myidDESCRIPTION Use this command to display
Fabric OS Command Reference 60353-1003108-01nbrStateShow2nbrStateShowDisplays the state of FSPF neighbors. SYNOPSIS nbrstateshow [slot/][port]DESCRIPT
604 Fabric OS Command Reference53-1003108-01nbrStateShow2ROUTABLE_SENDThe port is preparing for local route update; negotiates for the necessary locks
Fabric OS Command Reference 60553-1003108-01nbrStatsClear2nbrStatsClearResets FSPF interface counters. SYNOPSIS nbrstatsclear [slot/][port]DESCRIPTION
606 Fabric OS Command Reference53-1003108-01nbrStatsClear2To verify the changes:switch:admin> interfaceshow 1/0idbP = 0x10050a38Interfac
Fabric OS Command Reference 60753-1003108-01nodeFind2nodeFindDisplays all device Name Server (NS) entries matching a given WWN, device PID, or alias.
608 Fabric OS Command Reference53-1003108-01nodeFind2To display all the device information matching the alias "a320":switch:user> nodefin
Fabric OS Command Reference 60953-1003108-01nsAliasShow2nsAliasShowDisplays local Name Server (NS) information, with aliases. SYNOPSIS nsaliasshow [-r
610 Fabric OS Command Reference53-1003108-01nsAliasShow2-domain domain_idDisplays the remote device details for a specific domain.--helpDisplays the c
Fabric OS Command Reference 61153-1003108-01nsAliasShow2 Fabric Port Name: 20:06:00:05:1e:7a:7a:00 Permanent Port Name: 20:06:00:05:1e:38:81:71
36 Fabric OS Command Reference53-1003108-01ag2 0 4;6 None 4;6 1 0 2 SecondFabric 1 7;8;9 None 7;8;9 0
612 Fabric OS Command Reference53-1003108-01nsAliasShow2 Device Shared in Other AD: No Redirect: No Partial: No Aliases: DeviceAliasThe Lo
Fabric OS Command Reference 61353-1003108-01nsAllShow2nsAllShowDisplays global name server information. SYNOPSIS nsallshow [type]DESCRIPTION Use this
614 Fabric OS Command Reference53-1003108-01nsCamShow2nsCamShowDisplays information about remote devices in the Name Server (NS) cache. SYNOPSIS nscam
Fabric OS Command Reference 61553-1003108-01nsCamShow2VirtualThe device is contrived by the switch.NPV The device is connected to the NX_Port, using F
616 Fabric OS Command Reference53-1003108-01nsCamShow2 Partial: No N 5c1700; 3;23:00:00:05:1e:53:e3:8a;50:00:51:e5:3e:38:a0:00; FC4s: FCP Po
Fabric OS Command Reference 61753-1003108-01nsDevLog2nsDevLogManages device history logging.SYNOPSIS nsdevlog --show [[-slot slot] -port port |
618 Fabric OS Command Reference53-1003108-01nsDevLog2--clearClears the NS device history logs.--helpDisplays the command usage.EXAMPLES To enable devi
Fabric OS Command Reference 61953-1003108-01nsShow2nsShowDisplays local Name Server (NS) information. SYNOPSIS nsshow [-r][-t]DESCRIPTION Use this com
620 Fabric OS Command Reference53-1003108-01nsShow2PartialDisplays "Yes" if the device entry is incomplete; otherwise displays "No"
Fabric OS Command Reference 62153-1003108-01nsShow2VirtualThe device is contrived by the switch.NPV The device is connected to the NX_Port, using FDIS
Fabric OS Command Reference 3753-1003108-01ag2 _F_Ports _F_Ports --------------------------------------------------- 0 None None
622 Fabric OS Command Reference53-1003108-01nsShow2 Permanent Port Name: 21:00:00:e0:8b:13:08:10 Port Index: 1 Share Area: No Device Share
Fabric OS Command Reference 62353-1003108-01nsZoneMember2nsZoneMemberDisplays the information on online devices zoned with a specified device.SYNOPSIS
624 Fabric OS Command Reference53-1003108-01nsZoneMember2NOTES The execution of this command is subject to Virtual Fabric or Admin Domain restrictions
Fabric OS Command Reference 62553-1003108-01nsZoneMember2 Device type: Physical InitiatorNL 0416e2; 3;22:00:00:20:37:d9:6b:b3;20:00:00:20:37:d9:6b:
626 Fabric OS Command Reference53-1003108-01nsZoneMember2To display zoned device data for a device (either local or remote) in the fabric with the spe
Fabric OS Command Reference 62753-1003108-01nsZoneShow2nsZoneShowDisplays the zone names.SYNOPSIS nszoneshow -pid pidnszoneshow -wwn wwnnszoneshow -pi
628 Fabric OS Command Reference53-1003108-01nsZoneShow2EXAMPLES To display the zone names for a device with a specified PID: switch:admin> nszonesh
Fabric OS Command Reference 62953-1003108-01passwd2passwdChanges the password for a specified user. SYNOPSIS passwd [user_account] [-old old_p
630 Fabric OS Command Reference53-1003108-01passwd2NOTES The execution of this command is subject to Virtual Fabric or Admin Domain restrictions that
Fabric OS Command Reference 63153-1003108-01passwd2Password matches one of the previous passwordsThe password you entered matches one of the previous
38 Fabric OS Command Reference53-1003108-01ag2To set and display failback policy settings on a single port:switch:admin> ag --failbackenable 0Failb
632 Fabric OS Command Reference53-1003108-01passwdCfg2passwdCfgManages the password policies. SYNOPSIS passwdcfg --set options valuepasswdcfg --setuse
Fabric OS Command Reference 63353-1003108-01passwdCfg2The account lockout policy disables a user account when the user exceeds a configurable number o
634 Fabric OS Command Reference53-1003108-01passwdCfg2-minpasswordage valueSpecifies the minimum number of days that must elapse before a password can
Fabric OS Command Reference 63553-1003108-01passwdCfg2-minpasswordage valueSpecifies the minimum number of days that must elapse before a password can
636 Fabric OS Command Reference53-1003108-01passwdCfg2Digits value out of rangeThe -digits value specified must be greater than or equal to 0 and less
Fabric OS Command Reference 63753-1003108-01passwdCfg2passwdcfg.warning: 0passwdcfg.lockoutthreshold: 0passwdcfg.lockoutduration: 30passwdcfg.status:
638 Fabric OS Command Reference53-1003108-01pathInfo2pathInfoDisplays routing information and statistics along a path covering multiple switches. SYNO
Fabric OS Command Reference 63953-1003108-01pathInfo2For each hop, this command displays the following fields:HopThe hop number. The local switch is h
640 Fabric OS Command Reference53-1003108-01pathInfo2Extended statisticsExtended statistics report variables of general interest. They include the fol
Fabric OS Command Reference 64153-1003108-01pathInfo2NOTES The execution of this command is subject to Virtual Fabric or Admin Domain restrictions tha
Fabric OS Command Reference 3953-1003108-01ag2To remove the port group with pgid 2:switch:admin> ag --pgremove 2Port Group 2 has been removed succe
642 Fabric OS Command Reference53-1003108-01pathInfo2Source portSpecifies the port whose path to the destination domain is traced, specified as the po
Fabric OS Command Reference 64353-1003108-01pathInfo2To display path information when source port and destination port are provided along with the tra
644 Fabric OS Command Reference53-1003108-01pathInfo2Port 3 12 Tx Rx
Fabric OS Command Reference 64553-1003108-01pdShow2pdShowDisplays data from a panic dump file. SYNOPSIS pdshow [panic_dump_file]DESCRIPTION Use this c
646 Fabric OS Command Reference53-1003108-01perfAddEEMonitor2perfAddEEMonitorAdds an end-to-end monitor to a port. SYNOPSIS perfaddeemonitor [slot/]po
Fabric OS Command Reference 64753-1003108-01perfAddEEMonitor2The execution of this command is subject to Virtual Fabric or Admin Domain restrictions t
648 Fabric OS Command Reference53-1003108-01perfAddEEMonitor2 20:00:00:00:c9:52:00:7d Host PID: 01a000 VI: 20:01:
Fabric OS Command Reference 64953-1003108-01perfAddEEMonitor2 PortSymb: [24] "Crypto Virtual Initiator" NodeSymb: [37] "Ini Port ww
650 Fabric OS Command Reference53-1003108-01perfCfgClear2perfCfgClearClears the previously saved performance monitoring configuration settings from no
Fabric OS Command Reference 65153-1003108-01perfCfgRestore2perfCfgRestoreRestores performance monitoring configuration settings from nonvolatile memor
40 Fabric OS Command Reference53-1003108-01ag2To delete secondary port mapping for F_Ports 7, 8 and 9:switch:admin> ag --prefdel "7;8;9"
652 Fabric OS Command Reference53-1003108-01perfCfgSave2perfCfgSaveSaves performance monitoring configuration settings to nonvolatile memory. SYNOPSIS
Fabric OS Command Reference 65353-1003108-01perfClearAlpaCrc2perfClearAlpaCrcClears the CRC error count associated with a port and arbitrated loop phy
654 Fabric OS Command Reference53-1003108-01perfDelEEMonitor2perfDelEEMonitorDeletes one or all end-to-end performance monitors from a port. SYNOPSIS
Fabric OS Command Reference 65553-1003108-01perfHelp2perfHelpDisplays performance monitoring help information. SYNOPSIS perfhelpDESCRIPTION Use this c
656 Fabric OS Command Reference53-1003108-01perfMonitorClear2perfMonitorClearClears counters of end-to-end and ISL performance monitors on a port. SYN
Fabric OS Command Reference 65753-1003108-01perfMonitorClear2To clear statistics counters for an ISL monitor:switch:admin> perfmonitorclear --class
658 Fabric OS Command Reference53-1003108-01perfMonitorShow2perfMonitorShowDisplays end-to-end and interswitch link performance monitors on a port. SY
Fabric OS Command Reference 65953-1003108-01perfMonitorShow2intervalThe interval value must be greater than or equal to 5, and it must be a multiple o
660 Fabric OS Command Reference53-1003108-01perfResourceShow2perfResourceShowDisplays performance monitor resources for a logical switch. SYNOPSIS per
Fabric OS Command Reference 66153-1003108-01perfResourceShow2--helpDisplays the command usage.EXAMPLES To display the number of Top Talkers that can b
Fabric OS Command Reference 4153-1003108-01ag2To enable persistent ALPA in stringent mode:switch:admin> ag --persistentalpaenable 1 -sPersistent AL
662 Fabric OS Command Reference53-1003108-01perfResourceShow2 2 | | - | - | | - | | | | | | - | | 3 | | - | - | | - | | |
Fabric OS Command Reference 66353-1003108-01perfSetPortEEMask2perfSetPortEEMaskSets the overall mask for end-to-end (EE) performance monitors. SYNOPSI
664 Fabric OS Command Reference53-1003108-01perfSetPortEEMask2ffSpecifies that the field does triggers EE monitors.TxDIDMskSpecify the transmitting De
Fabric OS Command Reference 66553-1003108-01perfShowAlpaCrc2perfShowAlpaCrcDisplays the CRC error count by port or by arbitrated loop physical address
666 Fabric OS Command Reference53-1003108-01perfShowPortEEMask2perfShowPortEEMaskDisplays the current address mask for end-to-end performance monitors
Fabric OS Command Reference 66753-1003108-01perfShowPortEEMask2RxSID Area: onRxSID ALPA: onRxDID Domain: onRxDID Area: onRxDID ALPA: onSE
668 Fabric OS Command Reference53-1003108-01perfTTmon2perfTTmonInstalls the Top Talker monitor in the specified mode. SYNOPSIS perfttmonPort Mode:perf
Fabric OS Command Reference 66953-1003108-01perfTTmon2NOTES This command requires an Advanced Performance Monitor license.Top Talkers are incompatible
670 Fabric OS Command Reference53-1003108-01perfTTmon2-sconfigOn a Condor 3-based platforms, the -sconfig option deletes all stale Top Talker monitor
Fabric OS Command Reference 67153-1003108-01perfTTmon2To delete the Fabric Mode Top Talker:Switch:admin> perfttmon --del fabricmodeTo display the F
Fabric OS Command Reference vii53-1003108-01ContentsAbout This DocumentHow this document is organized . . . . . . . . . . . . . . . . . . . . . . . .
42 Fabric OS Command Reference53-1003108-01ag2To create a WWN to port group mapping for all currently mapped devices (this command does not affect dev
672 Fabric OS Command Reference53-1003108-01portAddress2portAddressAssigns the lower 16 bits of the Fibre Channel Port ID. SYNOPSIS portaddress --bind
Fabric OS Command Reference 67353-1003108-01portAddress2--autoEnables autobinding on the specified port. If the auto feature is enabled, the entire ar
674 Fabric OS Command Reference53-1003108-01portAddress2397 5 13 0x0500 8 bit -398 5 14 0x0600 8 bit -399 5 15 0x070
Fabric OS Command Reference 67553-1003108-01portAlpaShow2portAlpaShowDisplays the Arbitrated Loop Physical Addresses (AL_PAs) of devices attached to a
676 Fabric OS Command Reference53-1003108-01portBeacon2portBeaconSets port beaconing mode. SYNOPSIS portbeacon --enable [slot/]portportbeacon --disabl
Fabric OS Command Reference 67753-1003108-01portBeacon2--disableDisables beaconing mode on the specified port.--showDisplays the port beaconing mode o
678 Fabric OS Command Reference53-1003108-01portBufferCalc2portBufferCalcCalculates the number of buffers required per port.SYNOPSIS portbuffercalc [s
Fabric OS Command Reference 67953-1003108-01portBufferShow2portBufferShowDisplays the buffer usage information for a port group or for all port groups
680 Fabric OS Command Reference53-1003108-01portBufferShow2the return trip of a MARK primitive that is sent and then echoed back to the switch. LD mod
Fabric OS Command Reference 68153-1003108-01portBufferShow2196 - 8 - ( - ) - ( - )\ 0 -
Fabric OS Command Reference 4353-1003108-01ag2Backup mapping commands To save the configured, static, and preferred mapping of an N_Port:switch:admin&
682 Fabric OS Command Reference53-1003108-01portCamShow2portCamShowDisplays port-based filter CAM utilization. SYNOPSIS portcamshow [slot/]portDESCRIP
Fabric OS Command Reference 68353-1003108-01portCamShow2EXAMPLES To display the filter CAM utilization for a single port on a switch: switch:user>
684 Fabric OS Command Reference53-1003108-01portCfg2portCfgManages port configuration parameters for FC ports, VE_ports, and GbE/10GbE ports. SYNOPSIS
Fabric OS Command Reference 68553-1003108-01portCfg2DESCRIPTION Use this command to configure the following parameters on a local FC port. • portcfg m
686 Fabric OS Command Reference53-1003108-01portCfg2FUNCTION Configure IP interfaces on the Brocade 7800 switch and FX8-24 bladeSYNOPSIS portcfg actio
Fabric OS Command Reference 68753-1003108-01portCfg2mtu_sizeSpecifies the maximum transmission unit size. The permitted range is 1260 Bytes to 1500 By
688 Fabric OS Command Reference53-1003108-01portCfg2delete ipaddrDeletes IP routes for a specified IPv4 or IPv6 address. Valid ipaddr values include t
Fabric OS Command Reference 68953-1003108-01portCfg2-m | --mgmtSpecifying this parameter applies the VLAN tag to the inband management interface.EXAMP
690 Fabric OS Command Reference53-1003108-01portCfg2To delete an IP interface for a failover crossport:switch:admin> portcfg ipif 8/xge0 delete 192
Fabric OS Command Reference 69153-1003108-01portCfg22. Configure the interface for the nonlocal XGE port (xge1). switch:admin> portcfg ipif 8/xge1
44 Fabric OS Command Reference53-1003108-01agAutoMapBalance2agAutoMapBalanceControls automatic remapping of F_Ports in AG mode. SYNOPSIS agautomapbala
692 Fabric OS Command Reference53-1003108-01portCfg2To create a VLAN tag entry for a failover crossport interface with a VLAN ID of 200 and an L2 CoS
Fabric OS Command Reference 69353-1003108-01portCfg2NOTES You can configure up to 20 FCIP tunnels on the Brocade FX8-24 and up to 8 tunnels on the Bro
694 Fabric OS Command Reference53-1003108-01portCfg2The following two operands are exclusive; you can either specify a committed rate or a minimum and
Fabric OS Command Reference 69553-1003108-01portCfg21Enables write-read Tape Pipelining (FCIP FastWrite must also be enabled).2Enables write-only Tape
696 Fabric OS Command Reference53-1003108-01portCfg2-l | --legacy [0|1]In Fabric OS v7.0.0, the connection process for FCIP tunnels has changed in way
Fabric OS Command Reference 69753-1003108-01portCfg2--ficon-dvcack [0|1]Enables (1) or disables (0) FICON Device Level Acknowledgement emulation. This
698 Fabric OS Command Reference53-1003108-01portCfg2--write-timer valueDefines a time limit for pipelined write chains. This value is specified in mil
Fabric OS Command Reference 69953-1003108-01portCfg2-x | --metric metricSpecifies the metric for the configured circuit. The valid range is 0 to 1. Th
700 Fabric OS Command Reference53-1003108-01portCfg2--dscp-f-class dscpSpecifies the DSCP value for F-Class Traffic. The range is 0 to 63. The default
Fabric OS Command Reference 70153-1003108-01portCfg2modify [circuit_ID] [circuit_argumentsModifies the properties of an existing FCIP circuit. To modi
Fabric OS Command Reference 4553-1003108-01agAutoMapBalance2-nportEnables automatic login redistribution in the event that one or more N_Ports come on
702 Fabric OS Command Reference53-1003108-01portCfg2Valid options and arguments for mgmtroute include the following:createCreates a management route f
Fabric OS Command Reference 70353-1003108-01portCfg2 Max Comm Rt: 500000 SACK: On Min Retrans Time: 100 Max Retransmits: 8 Ke
704 Fabric OS Command Reference53-1003108-01portCfg2To set the failover group for circuit 1 and verify the configuration:switch:admin> portcfg fcip
Fabric OS Command Reference 70553-1003108-01portCfg2 Fastwrite: Off Tape Acceleration: Off TPerf Option: Off IPSec: Disabled Remote WWN: Not
706 Fabric OS Command Reference53-1003108-01portCfg2To modify an existing circuit so it becomes the initiator (the following example uses the string o
Fabric OS Command Reference 70753-1003108-01portCfg25. On the Management Station, add route entries to get to the Brocade 7800 external inband managem
708 Fabric OS Command Reference53-1003108-01portCfgAlpa2portCfgAlpaConfigures the AL_PA offset on a specified port or range of ports. SYNOPSIS portcfg
Fabric OS Command Reference 70953-1003108-01portCfgAutoDisable2portCfgAutoDisableManages the port autodisable configuration. SYNOPSIS portcfgautodisab
710 Fabric OS Command Reference53-1003108-01portCfgAutoDisable2port[-port]Specifies a port or a port range, relative to the slot number on bladed syst
Fabric OS Command Reference 71153-1003108-01portCfgAutoDisable2EXAMPLES To disable the port autodisable feature on single port:switch:admin> portcf
46 Fabric OS Command Reference53-1003108-01agAutoMapBalance2To disable automatic login redistribution on F_Port offline events:switch:admin> agauto
712 Fabric OS Command Reference53-1003108-01portCfgAutoDisable2Port will not be automatically disabled.Port Auto Disable: ONMODE : RESUMEC
Fabric OS Command Reference 71353-1003108-01portCfgCompress2portCfgCompressConfigures a port for compression. SYNOPSIS portcfgcompress --enable [slot]
714 Fabric OS Command Reference53-1003108-01portCfgCompress2switch:admin> lscfg --config 15 -port 2This operation requires that the affected ports
Fabric OS Command Reference 71553-1003108-01portCfgCreditRecovery2portCfgCreditRecoveryEnables or disables credit recovery on a port. SYNOPSIS portcfg
716 Fabric OS Command Reference53-1003108-01portCfgDefault2portCfgDefaultResets the port configuration to factory default value. SYNOPSIS portcfgdefau
Fabric OS Command Reference 71753-1003108-01portCfgDPort2portCfgDPortConfigures a port as a D_Port. SYNOPSIS portcfgdport --enable [-dwdm] [slot/]port
718 Fabric OS Command Reference53-1003108-01portCfgDPort2• A set of ports separated by commas, for example "3,5,7,8" or "5/3,5,7,8"
Fabric OS Command Reference 71953-1003108-01portCfgEncrypt2portCfgEncryptConfigures a port for encryption. SYNOPSIS portcfgencrypt --enable [slot]/por
720 Fabric OS Command Reference53-1003108-01portCfgEncrypt2To attempt to move a configured port to another logical switch:switch:admin> lscfg --con
Fabric OS Command Reference 72153-1003108-01portCfgEport2portCfgEportEnables or disables E_Port capability on a port or locks down a port as an E_Port
Fabric OS Command Reference 4753-1003108-01agShow2agShowDisplays the Access Gateway information registered with the fabric. SYNOPSIS agshowagshow --na
722 Fabric OS Command Reference53-1003108-01portCfgEport2modeSpecifies the E_Port configuration as one of the following:0Disables E_Port capability fo
Fabric OS Command Reference 72353-1003108-01portCfgEportCredits2portCfgEportCreditsConfigures normal distance E_Port buffer allocation. SYNOPSIS portc
724 Fabric OS Command Reference53-1003108-01portCfgEportCredits2creditsSpecifies the number of credits to be allocated to the specified port. The spec
Fabric OS Command Reference 72553-1003108-01portCfgEXPort2portCfgEXPortSets a port to be an EX_Port, and sets and displays EX_Port configuration param
726 Fabric OS Command Reference53-1003108-01portCfgEXPort2NOTES The fabric ID must be the same for every router port connected to the same edge fabric
Fabric OS Command Reference 72753-1003108-01portCfgEXPort2 -m port modeSpecifies the port mode. The -m option enforces the same port mode for all the
728 Fabric OS Command Reference53-1003108-01portCfgEXPort2To view the configuration of an ICL EX_Port:switch:admin> portcfgexport 5/12Port 5
Fabric OS Command Reference 72953-1003108-01portCfgFaultDelay2portCfgFaultDelayConfigures the fault delay for a single FC port. SYNOPSIS portcfgfaultd
730 Fabric OS Command Reference53-1003108-01portCfgFaultDelay2Locked L_Port OFFLocked G_Port OFFDisabled E_Port OFFL
Fabric OS Command Reference 73153-1003108-01portCfgFaultDelay2FEC .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. ..Fault Delay 0 0
48 Fabric OS Command Reference53-1003108-01agShow2OPERANDS This command has the following optional operands:--name ag_nameDisplays information regardi
732 Fabric OS Command Reference53-1003108-01portCfgFec2portCfgFecEnables or disables Forward Error Correction on 16 Gbps and 10 Gbps Fibre Channel lin
Fabric OS Command Reference 73353-1003108-01portCfgFec2NOTES FEC is supported the following links: • Between E_Ports on all Condor3-based platforms ru
734 Fabric OS Command Reference53-1003108-01portCfgFec2To disable the FEC feature on a port range:switch:admin> portcfgfec --disable 0-8SEE ALSO is
Fabric OS Command Reference 73553-1003108-01portCfgFillword2portCfgFillwordConfigures the fill word for a single 8G FC port. SYNOPSIS portcfgfillword
736 Fabric OS Command Reference53-1003108-01portCfgFillword21Specify 1 to postpone the new settings to take effect only after the next time the port g
Fabric OS Command Reference 73753-1003108-01portCfgFportBuffers2portCfgFportBuffersConfigures F_Port buffer allocation. SYNOPSIS portcfgfportbuffers -
738 Fabric OS Command Reference53-1003108-01portCfgGeMediaType2portCfgGeMediaTypeSets the selected mode for the ge0 and ge1 ports on the Brocade 7800.
Fabric OS Command Reference 73953-1003108-01portCfgGeMediaType2--helpDisplays the command usage.EXAMPLES To select an optical mode for ge0:switch:admi
740 Fabric OS Command Reference53-1003108-01portCfgGport2portCfgGportDesignates a port as a G_Port; removes G_Port designation. SYNOPSIS portcfggport
Fabric OS Command Reference 74153-1003108-01portCfgISLMode2portCfgISLModeEnables or disables ISL R_RDY mode on a port. SYNOPSIS portcfgislmode [slot/]
Fabric OS Command Reference 4953-1003108-01aliAdd2aliAddAdds a member to a zone alias. SYNOPSIS aliadd "aliName","member[; member...]&q
742 Fabric OS Command Reference53-1003108-01portCfgISLMode2To disable ISL R_RDY mode on a port: switch:admin> portcfgislmode 1/3, 0SEE ALSO configu
Fabric OS Command Reference 74353-1003108-01portCfgLongDistance2portCfgLongDistanceConfigures a port to support long distance links. SYNOPSIS portcfgl
744 Fabric OS Command Reference53-1003108-01portCfgLongDistance2distance_levelSpecifies the long distance level as one of the following (the numerical
Fabric OS Command Reference 74553-1003108-01portCfgLongDistance2-fecdisableDisables Forward Error Correction.EXAMPLES To configure a switch port 118 t
746 Fabric OS Command Reference53-1003108-01portCfgLongDistance2To confgiure average frame size:switch:admin> portcfglongdistance 2/35 \ LS 1
Fabric OS Command Reference 74753-1003108-01portCfgLossTov2portCfgLossTov Enables or disables de-bouncing of signal loss for front end ports. SYNOPSIS
748 Fabric OS Command Reference53-1003108-01portCfgLport2portCfgLportConfigures a port as an L_Port. SYNOPSIS portcfglport [[slot/]port] locked_mo
Fabric OS Command Reference 74953-1003108-01portCfgLport2To display the L_Port conditions:switch:admin> portcfglport[...]Ports of Slot 4 0 1 2
750 Fabric OS Command Reference53-1003108-01portCfgNPIVPort2portCfgNPIVPortEnables or disables N_Port ID virtualization (NPIV) functionality on a port
Fabric OS Command Reference 75153-1003108-01portCfgNPIVPort2NOTES The execution of this command is subject to Virtual Fabric or Admin Domain restricti
50 Fabric OS Command Reference53-1003108-01aliCreate2aliCreateCreates a zone alias. SYNOPSIS alicreate "aliName","member[; member...]&q
752 Fabric OS Command Reference53-1003108-01portCfgNPIVPort2Persistent Disable.. .. ON ON .. .. .. .. .. .. .. .. .. .. .. ..LOS TOV enable .. .
Fabric OS Command Reference 75353-1003108-01portCfgNPIVPort2Persistent Disable OFFLOS TOV enable OFFNPIV capability OFFQOS
754 Fabric OS Command Reference53-1003108-01portCfgNPort2portCfgNPortEnables or disables N_Port functionality for an Access Gateway port. SYNOPSIS por
Fabric OS Command Reference 75553-1003108-01portCfgOctetSpeedCombo2portCfgOctetSpeedComboSets port speed combination for a port octet. SYNOPSIS portcf
756 Fabric OS Command Reference53-1003108-01portCfgOctetSpeedCombo2comboSpecifies the speed combination for the ports in the octet. The following spee
Fabric OS Command Reference 75753-1003108-01portCfgPersistentDisable2portCfgPersistentDisablePersistently disables a port or a range of ports. SYNOPSI
758 Fabric OS Command Reference53-1003108-01portCfgPersistentDisable2port1[-port2]Persistently disables a single port or a range of ports identified b
Fabric OS Command Reference 75953-1003108-01portCfgPersistentDisable2To display the persistently disabled ports on the switch:switch:admin> portcfg
760 Fabric OS Command Reference53-1003108-01portCfgPersistentEnable2portCfgPersistentEnablePersistently enables a port or a range of ports. SYNOPSIS p
Fabric OS Command Reference 76153-1003108-01portCfgPersistentEnable2-i index1[-index2]Persistently enables a port or a range of ports identified by po
Fabric OS Command Reference 5153-1003108-01aliDelete2aliDeleteDeletes a zone alias. SYNOPSIS alidelete "aliName" DESCRIPTION Use this comman
762 Fabric OS Command Reference53-1003108-01portCfgQoS2portCfgQoSEnables or disables QoS, sets the default configuration, and sets and resets the ingr
Fabric OS Command Reference 76353-1003108-01portCfgQoS2OPERANDS This command has the following operands:slotFor bladed systems only, specifies the slo
764 Fabric OS Command Reference53-1003108-01portCfgQoS2To enable CS_CTL VC mode on a port when QoS is enabled.:switch:admin> portcfgqos --enable 1/
Fabric OS Command Reference 76553-1003108-01portCfgShow2portCfgShowDisplays port configuration settings. SYNOPSIS portcfgshowportcfgshow [slot/]portpo
766 Fabric OS Command Reference53-1003108-01portCfgShow23Autonegotiated or fixed port speeds of 16 Gbps and 10 Gbps.SpeedDisplays Auto for auto speed
Fabric OS Command Reference 76753-1003108-01portCfgShow2Disabled E_Port Displays ON when the port is not allowed to be an E_Port. Displays (..) or OFF
768 Fabric OS Command Reference53-1003108-01portCfgShow2Credit Recovery Displays ON when Credit Recovery is enabled on the port. Displays (..) or OFF
Fabric OS Command Reference 76953-1003108-01portCfgShow2When portCfgShow is issued for a single FCoE port, only the following fields are displayed: Ar
770 Fabric OS Command Reference53-1003108-01portCfgShow2vlantagDisplays the VLAN tagging configuration. For each entry, the output displays the IP int
Fabric OS Command Reference 77153-1003108-01portCfgShow2NPIV capability ONQOS E_Port AEPort Auto Disable: ON LOSG O
viii Fabric OS Command Reference53-1003108-01agShow . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
52 Fabric OS Command Reference53-1003108-01aliRemove2aliRemoveRemoves a member from a zone alias. SYNOPSIS aliremove "aliName","member[
772 Fabric OS Command Reference53-1003108-01portCfgShow2To display the port configuration settings for all ports on slot 1 on a Brocade DCX 8510-4: sw
Fabric OS Command Reference 77353-1003108-01portCfgShow2Port Auto Disable .. .. .. .. .. .. .. .. .. .. .. .. .. .. .. ..CSCTL mode .. .. ..
774 Fabric OS Command Reference53-1003108-01portCfgShow2NPIV PP Limit 126 126 126 126 126 126 126 126 [truncated]QOS E_Port - - -
Fabric OS Command Reference 77553-1003108-01portCfgShow2To display an FCIP Tunnel on a Brocade FX8-24 with and without IPSec information (In the follo
776 Fabric OS Command Reference53-1003108-01portCfgShow2To display the management route for a configured inband management interface on a Brocade 7800
Fabric OS Command Reference 77753-1003108-01portCfgSpeed2portCfgSpeedConfigures the speed for a port or a range of ports. SYNOPSIS portcfgspeed [slot/
778 Fabric OS Command Reference53-1003108-01portCfgSpeed2-x hex1 [-hex2]Configures a port or a range of ports identified by port numbers, index number
Fabric OS Command Reference 77953-1003108-01portCfgSpeed2To set the speed of all ports in a range:switch:admin> portcfgspeed -x 1d-1e 8SEE ALSO por
780 Fabric OS Command Reference53-1003108-01portCfgTrunkPort2portCfgTrunkPortEnables or disables trunking on a port. SYNOPSIS portcfgtrunkport [slot/]
Fabric OS Command Reference 78153-1003108-01portCfgVEXPort2portCfgVEXPortConfigures a port as a VEX_Port connected to an FC-IP and sets and displays V
Fabric OS Command Reference 5353-1003108-01aliShow2aliShowDisplays zone alias information. SYNOPSIS alishow [--ic] ["pattern"][, mode]alisho
782 Fabric OS Command Reference53-1003108-01portCfgVEXPort2OPERANDS This command has the following operands:-a adminEnables or disables the specified
Fabric OS Command Reference 78353-1003108-01portCfgVEXPort2To set the fabric ID of port 2/21 to 5 and the port ID format to core:switch:admin> port
784 Fabric OS Command Reference53-1003108-01portCmd2portCmdDiagnoses intelligent ports. SYNOPSIS portcmd --ping [slot/][slot/]ge port -s src_ip -
Fabric OS Command Reference 78553-1003108-01portCmd2VLAN tagging ensures that test traffic traverses the same path as real FCIP traffic. A VLAN tag en
786 Fabric OS Command Reference53-1003108-01portCmd2-z sizeSpecifies the default packet size to a fixed size in bytes. The default is 64 bytes. In an
Fabric OS Command Reference 78753-1003108-01portCmd2-v vlan_idSpecifies the VLAN ID. Values must be in the range between 1 and 4094. There is no defau
788 Fabric OS Command Reference53-1003108-01portCmd2-pattern pattern Specifies the test data pattern for the payload as one of the following values:0
Fabric OS Command Reference 78953-1003108-01portCmd2To verify if packets can be sent to the destination IP address using VLAN tagging with the -c opti
790 Fabric OS Command Reference53-1003108-01portCmd2To configure a TPerf source so it generates round-trip high and low priority traffic with a random
Fabric OS Command Reference 79153-1003108-01portDebug2portDebugSets debug level and verbose level of port modules. SYNOPSIS portdebug dbg_lvl, vbs_lvl
54 Fabric OS Command Reference53-1003108-01appLoginHistory2appLoginHistoryDisplays the history of HTTP login sessions. SYNOPSIS apploginhistory --show
792 Fabric OS Command Reference53-1003108-01portDecom2portDecomDecommissions and disables an E_Port without frame loss. SYNOPSIS portdecomportdecom [s
Fabric OS Command Reference 79353-1003108-01portDisable2portDisableDisables a port or a range of ports. SYNOPSIS portdisable [slot/]port1[-port2] [...
794 Fabric OS Command Reference53-1003108-01portDisable2-x [hex1 [-hex2]]Disables a port or a range of ports identified by port numbers, index number
Fabric OS Command Reference 79553-1003108-01portDPortTest2portDPortTest Initiates or terminates a D_Port test, or displays D_Port test results. SYNOPS
796 Fabric OS Command Reference53-1003108-01portDPortTest2Test frame sizeThe test frame size in bytes.PatternThe pre-defined pattern name.PayloadThe u
Fabric OS Command Reference 79753-1003108-01portDPortTest2Use the --show all command to display the following test summary information:PortThe port nu
798 Fabric OS Command Reference53-1003108-01portDPortTest2-pattern pat_nameSpecifies the name of the predefined pattern to be used in the payload. Val
Fabric OS Command Reference 79953-1003108-01portDPortTest2End time: Mon Jan 16 05:58:56 2012Status: PASSED =================
800 Fabric OS Command Reference53-1003108-01portEnable2portEnableEnables a port or a range of ports. SYNOPSIS portenable [slot/]port1[-port2] [...]por
Fabric OS Command Reference 80153-1003108-01portEnable2-x [hex1 [-hex2]]Enables a port or a range of ports identified by port numbers, index number in
Fabric OS Command Reference 5553-1003108-01appLoginHistory2active currently:2011/10/13-15:51:31.203814, 10.20.10.160, admin, DCFM-HttpConnector/null20
802 Fabric OS Command Reference53-1003108-01portEncCompShow2portEncCompShowDisplays encryption and compression port configuration details. SYNOPSIS po
Fabric OS Command Reference 80353-1003108-01portEncCompShow2 147 No No No No 148 No No No No 149 Yes No
804 Fabric OS Command Reference53-1003108-01portErrShow2portErrShowDisplays a port error summary. SYNOPSIS porterrshowDESCRIPTION Use this command to
Fabric OS Command Reference 80553-1003108-01portErrShow2c3-timeout txThe number of transmit class 3 frames discarded at the transmission port due to t
806 Fabric OS Command Reference53-1003108-01portFencing2portFencingConfigures the Fabric Watch port fencing feature. SYNOPSIS portfencing --showportf
Fabric OS Command Reference 80753-1003108-01portFencing2The following operands are required with the --enable and --disable options.port_type_list | a
808 Fabric OS Command Reference53-1003108-01portFencing2To display the current port fencing configuration:switch:admin> portFencing --show Port Ty
Fabric OS Command Reference 80953-1003108-01portFlagsShow2portFlagsShowDisplays the port status bitmaps for all ports in a switch. SYNOPSIS portflagss
810 Fabric OS Command Reference53-1003108-01portFlagsShow2 19 Offline No_Module PRESENT U_PORT LED 20 Offline No_Module PRESENT U_PORT LED
Fabric OS Command Reference 81153-1003108-01portLedTest2portLedTestCycles user port LEDs. SYNOPSIS portledtest [--slot slot_number] [-ports i
56 Fabric OS Command Reference53-1003108-01aptPolicy2aptPolicyChanges or displays the Advanced Performance Tuning (APT) policy. SYNOPSIS aptpolicy [po
812 Fabric OS Command Reference53-1003108-01portLedTest2-npass countSpecify the number of times to perform this test. The default value is 10.-action
Fabric OS Command Reference 81353-1003108-01portLogClear2portLogClearClears the port log. SYNOPSIS portlogclearDESCRIPTION Use this command to clear t
814 Fabric OS Command Reference53-1003108-01portLogConfigShow2portLogConfigShowDisplays the current port log configuration. SYNOPSIS portlogconfigshow
Fabric OS Command Reference 81553-1003108-01portLogDisable2portLogDisableDisables the port log facility. SYNOPSIS portlogdisableDESCRIPTION Use this c
816 Fabric OS Command Reference53-1003108-01portLogDump2portLogDumpDisplays the port log without page breaks. SYNOPSIS portlogdump [count[, saved]]DES
Fabric OS Command Reference 81753-1003108-01portLogDumpPort2portLogDumpPortDisplays the port log of a specified port without page breaks. SYNOPSIS por
818 Fabric OS Command Reference53-1003108-01portLogEnable2portLogEnableEnables the port log facility. SYNOPSIS portogenableDESCRIPTION Use this comman
Fabric OS Command Reference 81953-1003108-01portLogEventShow2portLogEventShowDisplays information about port log events. SYNOPSIS portlogeventshowDESC
820 Fabric OS Command Reference53-1003108-01portLoginShow2portLoginShowDisplays port login status of devices attached to the specified port. SYNOPSIS
Fabric OS Command Reference 82153-1003108-01portLoginShow2EXAMPLES To display the logins received by Port 23 (revealing one FLOGI (type fe) and two PL
Fabric OS Command Reference 5753-1003108-01aptPolicy2This policy optimizes the utilization of the available paths by allowing I/O traffic between diff
822 Fabric OS Command Reference53-1003108-01portLogPdisc2portLogPdiscSets or clears the debug_pdisc_flag. SYNOPSIS portlogpdisc 0 | 1DESCRIPTION Use t
Fabric OS Command Reference 82353-1003108-01portLogReset2portLogResetEnables the port log facility. SYNOPSIS portlogresetDESCRIPTION Use this command
824 Fabric OS Command Reference53-1003108-01portLogResize2portLogResizeResizes the port log to include a specified number of entries. SYNOPSIS portlog
Fabric OS Command Reference 82553-1003108-01portLogShow2portLogShowDisplays the port log with page breaks. SYNOPSIS portlogshow [count[, saved]]DESCRI
826 Fabric OS Command Reference53-1003108-01portLogShow2ctoutA CT based response is transmitted.errlogA message is added to the error log.loopscnA loo
Fabric OS Command Reference 82753-1003108-01portLogShow2Tx & RxFrame payload size.scnNew state (see state codes below).pstateNew physical state (s
828 Fabric OS Command Reference53-1003108-01portLogShow2ctinArgument 0 is divided into two 16-bit fields: [A] A bit map indicating whether subsequent
Fabric OS Command Reference 82953-1003108-01portLogShow24Faulty5E_Port6F_Port7SegmentedpstateValid pstate values include the following:ACActive StateL
830 Fabric OS Command Reference53-1003108-01portLogShow28009LIP as requested by the LINIT ELS received.800aLIP as requested by the LPC ELS received.Sp
Fabric OS Command Reference 83153-1003108-01portLogShow217:05:31.775 PORT Tx 2 40 02fffffd,00fffffd,0e08ffff,1400000017:05:31.775 PORT debug 2
58 Fabric OS Command Reference53-1003108-01aptPolicy2To change the current APT policy to the AP Shared Link Policy:switch:admin> aptpolicy -ap 0Swi
832 Fabric OS Command Reference53-1003108-01portLogShowPort2portLogShowPortDisplays the port log of a specified port with page breaks. SYNOPSIS portlo
Fabric OS Command Reference 83353-1003108-01portLogTypeDisable2portLogTypeDisableDisables the port log of a specified type. SYNOPSIS portlogtypedisabl
834 Fabric OS Command Reference53-1003108-01portLogTypeEnable2portLogTypeEnableEnables the port log of a specified port log type. SYNOPSIS portlogtype
Fabric OS Command Reference 83553-1003108-01portLoopbackTest2portLoopbackTestPerforms a functional test of port N->N path. SYNOPSIS portloopbacktes
836 Fabric OS Command Reference53-1003108-01portLoopbackTest2At each pass, the frame is created from a different data type of a palette of seven. If s
Fabric OS Command Reference 83753-1003108-01portLoopbackTest28Backend bypass & SERDES loopback (supported only on a chassis)-spd_mode modeSpecifie
838 Fabric OS Command Reference53-1003108-01portLoopbackTest2XMITFrame transmission failure.EXAMPLES To run a functional test in default mode:switch:a
Fabric OS Command Reference 83953-1003108-01portMirror2portMirrorAdds, deletes, or displays port mirror connections. SYNOPSIS portmirrorportmirror --s
840 Fabric OS Command Reference53-1003108-01portMirror2StateThe state of the mirror connection. The state can either be "Defined" or "E
Fabric OS Command Reference 84153-1003108-01portMirror2--deleteDeletes a mirror connection between a source and a destination. You must specify a SID
Fabric OS Command Reference 5953-1003108-01auditCfg2auditCfgModifies and displays the audit log filter configuration. SYNOPSIS auditcfg --class audit_
842 Fabric OS Command Reference53-1003108-01portMirror2To display the mirror connections:switch:admin> portmirror --show Number of mirror connectio
Fabric OS Command Reference 84353-1003108-01portName2portNameAssigns or displays port names. SYNOPSIS portnameportname [slot/]port [-n name]portname -
844 Fabric OS Command Reference53-1003108-01portName2-slot [slot1[-slot2]Assigns a name to all ports on a slot or on a range of slots, for example, -s
Fabric OS Command Reference 84553-1003108-01portPerfShow2portPerfShowDisplays port throughput performance. SYNOPSIS portperfshowportperfshow [[slot/]p
846 Fabric OS Command Reference53-1003108-01portPerfShow2-rxDisplays the receiver throughput.-tx -rxDisplays the transmitter and receiver throughput.
Fabric OS Command Reference 84753-1003108-01portPerfShow216 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31========================
848 Fabric OS Command Reference53-1003108-01portPerfShow2To display port performance on a chassis for range of ports at an interval of 5 seconds:switc
Fabric OS Command Reference 84953-1003108-01portRouteShow2portRouteShowDisplays routing tables for the specified port. SYNOPSIS portrouteshow [slot/]p
850 Fabric OS Command Reference53-1003108-01portRouteShow2EXAMPLES To display the routing tables for a port: switch:user> portrouteshow 4/15port ad
Fabric OS Command Reference 85153-1003108-01portShow2portShowDisplays status and configuration parameters for ports and GbE ports. SYNOPSIS portshow [
60 Fabric OS Command Reference53-1003108-01auditCfg2EXAMPLES To configure the audit log filter:switch:admin> auditcfg --class 2,3,8Audit filter is
852 Fabric OS Command Reference53-1003108-01portShow2FUNCTION General port status display commands supported on all platforms SYNOPSIS portshow [slot/
Fabric OS Command Reference 85353-1003108-01portShow2OnlineUp and running.OfflineNot online, see portPhys for more detail.TestingRunning diagnostics.F
854 Fabric OS Command Reference53-1003108-01portShow2portWwn of devices(s) connectedThe World Wide Port Names of connected devices.DistanceThe port&ap
Fabric OS Command Reference 85553-1003108-01portShow2Edge fabric's primary WWNIf the EX_Port is connected to an edge switch with FCS policy enfor
856 Fabric OS Command Reference53-1003108-01portShow2portSpecifies the number of the port to be displayed, relative to its slot for bladed systems. Us
Fabric OS Command Reference 85753-1003108-01portShow2To display the current state of a port with encryption enabled:switch:admin> portshow 10/44por
858 Fabric OS Command Reference53-1003108-01portShow2To display an FCoE port:switch:admin> portshow 8portIndex: 8portName:portHealth: HEALTHYAuth
Fabric OS Command Reference 85953-1003108-01portShow2ipifDisplays the IP interface ID, IP address, netmask, and MTU for IPv4 addresses. Displays the p
860 Fabric OS Command Reference53-1003108-01portShow2Port: ge0IP Address Mask Gateway Metric Flags---------------------------
Fabric OS Command Reference 86153-1003108-01portShow2192.168.12.103 255.255.255.255 * 0 U C (crossport)192.168.12.201 255.255.255.
Fabric OS Command Reference 6153-1003108-01auditDump2auditDumpDisplays or clears the audit log. SYNOPSIS auditdump -s | -showauditdump -c | -clearDESC
862 Fabric OS Command Reference53-1003108-01portShow2DESCRIPTION Use this command to display configuration parameters and status information for FCIP
Fabric OS Command Reference 86353-1003108-01portShow2--lifetimeDisplays the entire lifetime statistics for FCIP Tunnels, Circuits and the associated T
864 Fabric OS Command Reference53-1003108-01portShow2-q | --qosDisplays the QoS statistics including performance for each priority. This operand is op
Fabric OS Command Reference 86553-1003108-01portShow2-dumpDisplays a raw data dump including data for all information types.paramLimits output to one
866 Fabric OS Command Reference53-1003108-01portShow2when you first issue this command or any other performance monitor commands after a reboot, the c
Fabric OS Command Reference 86753-1003108-01portShow2-rteDisplays the current Routing Info SE memory.EXAMPLES To display FCIP tunnel configuration par
868 Fabric OS Command Reference53-1003108-01portShow2To display an FCIP tunnel with additional circuit information:switch:admin> portshow fciptunne
Fabric OS Command Reference 86953-1003108-01portShow2 Path MTU Disc: 0 VLAN ID: (Not Configured) L2CoS: (VLAN Not Configured) DSCP
870 Fabric OS Command Reference53-1003108-01portShow2 Oper Status: Up Compression: Off Fastwrite: Off Tape Acceleration: Off TPerf Option: O
Fabric OS Command Reference 87153-1003108-01portShow2 Packets Received: 1135181 Receive Window: 20832768 Bytes, max: 20832768
Fabric OS Command Reference ix53-1003108-01cfgTransAbort . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
62 Fabric OS Command Reference53-1003108-01authUtil2authUtilDisplays and sets the authentication configuration. SYNOPSIS authutilauthutil --showauthut
872 Fabric OS Command Reference53-1003108-01portShow2 1.91 : 1 Compression Ratio Performance Statistics: Overall Throughput 828
Fabric OS Command Reference 87353-1003108-01portShow2 Slow Starts: 0 ------------------------------------------- TCP Connection 2
874 Fabric OS Command Reference53-1003108-01portShow2 Unacked data: 0 Retransmit Timeout: 100 ms, Duplicate ACKs 0 Re
Fabric OS Command Reference 87553-1003108-01portShow2 Performance Statistics: Overall Throughput 114091792780 Output Bytes 193
876 Fabric OS Command Reference53-1003108-01portShow2 Slow Starts: 0 ------------------------------------------- TCP Connection 2
Fabric OS Command Reference 87753-1003108-01portShow2 Unacked data: 0 Retransmit Timeout: 100 ms, Duplicate ACKs 0 Re
878 Fabric OS Command Reference53-1003108-01portShow2 | TCP Bytes In: 842506236 | TCP Bytes Out: 1446465008 | TCP Packets In: 16072571 | TCP P
Fabric OS Command Reference 87953-1003108-01portShow2 | Aggregate TCP Stats: | TCP Bytes In: 773873596 | TCP Bytes Out: 12722541
880 Fabric OS Command Reference53-1003108-01portShow2 a=aggressive compression A=Auto compression f=fastwrite t=Tapepi
Fabric OS Command Reference 88153-1003108-01portShow2To display a summary view of the QoS configuration on FCIP tunnels and circuits on the Brocade FX
Fabric OS Command Reference 6353-1003108-01authUtil2enabled. Specifying "*" enables all DH groups 0, 1, 2, 3, and 4, in that order. This mea
882 Fabric OS Command Reference53-1003108-01portShow21/12 1 1/xge0 Up ---4-xs 3d2m 0.00 0.00 1 2500/2500 1/-1/21 0 1/xge1 Up ---4
Fabric OS Command Reference 88353-1003108-01portShow2 Flags: 0x00000000 ------------------------------------------- Circuit ID: 1/21.0 C
884 Fabric OS Command Reference53-1003108-01portShow2 Performance Statistics: Overall Throughput 31073824 Output Bytes 16 Bps
Fabric OS Command Reference 88553-1003108-01portShow2 318824216 Output Bytes 3419555 Output Packets 184935644 Input B
886 Fabric OS Command Reference53-1003108-01portShow2 0 pkt/s 30s Avg, 0 pkt/s Lifetime Avg 0 Input Bytes 0 Bps 30s Avg,
Fabric OS Command Reference 88753-1003108-01portShow2Port: ge1IP Address Mask Gateway Metric Flags---------------------------
888 Fabric OS Command Reference53-1003108-01portShow2WIRE Buffer Percentages LocalFree= 95 LocalLow= 93 \ PeerFree= 95 PeerLow=93XBAR Buffer Percen
Fabric OS Command Reference 88953-1003108-01portShow2To display the FICON Device Path Blocks:switch:admin> portshow xtun 23 -ficon -fdpb FDPB (FICO
890 Fabric OS Command Reference53-1003108-01portShow2To display FICON FCUB information (FICON Images accessed through the tunnel)switch:admin> port
Fabric OS Command Reference 89153-1003108-01portShow2CONTROL=======active = No Send_SYR = No crrSet = NoxrcEstablish
64 Fabric OS Command Reference53-1003108-01authUtil2onSets the authentication policy to "on" mode. Authentication is mandatory. If the attac
892 Fabric OS Command Reference53-1003108-01portShow2 egressFrameCount = 0x00000000000432ABTERADATA CONTROL============ writeSuspendFlag = OFF final
Fabric OS Command Reference 89353-1003108-01portShow2 sentUExceptn=OFF earlyEnd=OFF dackPending=OFF sofCNReceived=OFF noActive
894 Fabric OS Command Reference53-1003108-01portShow2switch:admin> portshow xtun 23 -ficon -emulxrc XRC EMULATION STA
Fabric OS Command Reference 89553-1003108-01portShow2TotalEmulErrors = 0 TotalCuLinkBusy = 0TotalPurgePaths =
896 Fabric OS Command Reference53-1003108-01portShow2 Largest write chain processed = 43936 Total number of emulated Write Byte
Fabric OS Command Reference 89753-1003108-01portShow2 Bit 19 [0x00080000] = 1 : DISPLAY_FDCB_ON_ERROR Bit 18 [0x00040000] = 0 : TRIGGER_ON_LOW_WIREP
898 Fabric OS Command Reference53-1003108-01portShow2 Emulated CCWs per sec: 3069 Ave Write Block Size: 32760 Emulated Write BPS
Fabric OS Command Reference 89953-1003108-01portStats64Show2portStats64ShowDisplays the 64-bit hardware statistics for a port. SYNOPSIS portstats64sho
900 Fabric OS Command Reference53-1003108-01portStats64Show2er64_disc_c3Number of class 3 frames discarded.er64_pcs_blkNumber of Physical Coding Subla
Fabric OS Command Reference 90153-1003108-01portStats64Show2swConnUnitFLNumOfTenancy, fl_tenancy Number of times the FL_Port had a loop tenancy.swConn
Fabric OS Command Reference 6553-1003108-01authUtil2To enable Sha256 hash type:sha256 hash type is recommended only for FIPS configuration. switch:adm
902 Fabric OS Command Reference53-1003108-01portStats64Show2EXAMPLES To display the 64-bit hardware statistics for a port:switch:user> portstats64s
Fabric OS Command Reference 90353-1003108-01portStats64Show2 0 bottom_int : 4-byte words transmittedstat64_PBSYFrames
904 Fabric OS Command Reference53-1003108-01portStatsClear2portStatsClearClears port hardware statistics. SYNOPSIS portstatsclear [slot/]portportstats
Fabric OS Command Reference 90553-1003108-01portStatsClear2-hDisplays the command usage.EXAMPLES To clear hardware statistics for a single port specif
906 Fabric OS Command Reference53-1003108-01portStatsShow2portStatsShowDisplays port hardware statistics. SYNOPSIS portstatsshow [slot/]portportstatss
Fabric OS Command Reference 90753-1003108-01portStatsShow2stat_mc_rxThe number of multicast frames received.stat_mc_toThe number of multicast timeouts
908 Fabric OS Command Reference53-1003108-01portStatsShow2er_rx_c3_timeoutThe number of receive class 3 frames received at this port and discarded at
Fabric OS Command Reference 90953-1003108-01portStatsShow2openedThe number of times the FL_Port entered OPENED state.starve_stopThe number of loop ten
910 Fabric OS Command Reference53-1003108-01portStatsShow2ge_err_overrunThe number of overruns observed on the GbE port.ge_err_fifo_ovfThe number of t
Fabric OS Command Reference 91153-1003108-01portStatsShow2tunnel_numberSpecifies a tunnel ID to display statistics only for the specified FCIP tunnel.
66 Fabric OS Command Reference53-1003108-01authUtil2To start authentication on E/F_Ports 2, 3, and 4:switch:admin> authutil --authinit 2,3,4Warnin
912 Fabric OS Command Reference53-1003108-01portStatsShow2fl_tenancy 0 number of times FL has the tenancynl_tenancy 0
Fabric OS Command Reference 91353-1003108-01portSwap2portSwapSwaps two ports or removes swapping of ports. SYNOPSIS portswap [slot1/]port1 [slot2/]por
914 Fabric OS Command Reference53-1003108-01portSwap2EXAMPLES To swap area numbers between a pair of ports: switch:admin> portswap 8/1 8/2portswap
Fabric OS Command Reference 91553-1003108-01portSwapDisable2portSwapDisableDisables the PortSwap feature. SYNOPSIS portswapdisableDESCRIPTION Use this
916 Fabric OS Command Reference53-1003108-01portSwapEnable2portSwapEnableEnables the PortSwap feature. SYNOPSIS portswapenableDESCRIPTION Use this com
Fabric OS Command Reference 91753-1003108-01portSwapShow2portSwapShowDisplays the state of the PortSwap feature. SYNOPSIS portswapshowDESCRIPTION Use
918 Fabric OS Command Reference53-1003108-01portTest2portTestPerforms a functional test of a switch in a live fabric. SYNOPSIS porttest [-ports it
Fabric OS Command Reference 91953-1003108-01portTest2Use the stopPortTest command to stop the test. Refer to the stopPortTest help page for more infor
920 Fabric OS Command Reference53-1003108-01portTest2-5All N->N loopback ports.EXAMPLES To run a functional test on an active switch: switch:admin&
Fabric OS Command Reference 92153-1003108-01portTestShow2portTestShowDisplays information from portTest.SYNOPSIS porttestshow [-ports itemlist]DESCRIP
Fabric OS Command Reference 6753-1003108-01bannerSet2bannerSetSets the banner on the local switch. SYNOPSIS bannerset [banner]DESCRIPTION Use this com
922 Fabric OS Command Reference53-1003108-01portTestShow2NOTES The execution of this command is subject to Virtual Fabric or Admin Domain restrictions
Fabric OS Command Reference 92353-1003108-01portThConfig2portThConfigConfigures Fabric Watch event thresholds per port type. SYNOPSIS portthconfig --s
924 Fabric OS Command Reference53-1003108-01portThConfig2NOTES The execution of this command is subject to Virtual Fabric or Admin Domain restrictions
Fabric OS Command Reference 92553-1003108-01portThConfig2LRLink reset TUTrunk UtilizationOnly the following areas are valid for VE_Ports.UTILPort util
926 Fabric OS Command Reference53-1003108-01portThConfig2emailEvent triggers an e-mail.portlogLocks the port log. Following an event, the port log loc
Fabric OS Command Reference 92753-1003108-01portThConfig2--pause | --continue argumentsPauses or resumes monitoring. The following arguments are requi
928 Fabric OS Command Reference53-1003108-01portThConfig2 -trigger above -action snmp -nosaveswitch:admin> portthconfig --set ve-port -area uti
Fabric OS Command Reference 92953-1003108-01portThConfig2 Trigger : Above Action: None Trigger : Below Action: Non
930 Fabric OS Command Reference53-1003108-01portThConfig2 Trigger : Below Action: None Default: TimeBas
Fabric OS Command Reference 93153-1003108-01portThConfig2E-port |CRC |000009|n/a |0 |Info |ContinueE-port |CRC |000010|n/a |0
68 Fabric OS Command Reference53-1003108-01bannerShow2bannerShowDisplays the banner text. SYNOPSIS bannershowDESCRIPTION Use this command to display t
932 Fabric OS Command Reference53-1003108-01portTrunkArea2portTrunkAreaAssigns or removes a trunk area (TA) from a port or port trunk group; displays
Fabric OS Command Reference 93353-1003108-01portTrunkArea2The --show trunk option displays the following information:Trunk IndexDisplays the trunk ind
934 Fabric OS Command Reference53-1003108-01portTrunkArea2• Ports included in a TA share the same port index. The original port index may be removed i
Fabric OS Command Reference 93553-1003108-01portTrunkArea2trunkDisplays configuration details for the port trunk group, including user port, neighbori
936 Fabric OS Command Reference53-1003108-01portTrunkArea2To display trunk details for a user assigned TA 25 that includes ports 24-25:switch:admin>
Fabric OS Command Reference 93753-1003108-01portZoneShow2portZoneShowDisplays the enforced zone type of the F_Ports and FL_Ports of a switch. SYNOPSIS
938 Fabric OS Command Reference53-1003108-01powerOffListSet2powerOffListSetSets the order in which slots are powered off. SYNOPSIS powerofflistsetDESC
Fabric OS Command Reference 93953-1003108-01powerOffListSet26th slot to be powered off: (7..9) [8] 97th slot to be powered off: (7..8) [8] 88th slot t
940 Fabric OS Command Reference53-1003108-01powerOffListShow2powerOffListShowDisplays the order in which slots are powered off. SYNOPSIS powerofflists
Fabric OS Command Reference 94153-1003108-01powerOffListShow2Slot 5 will be powered off 6thSlot 4 will be powered off 7thSlot 3 will be powered off
Fabric OS Command Reference 6953-1003108-01bcastShow2bcastShowDisplays broadcast routing information. SYNOPSIS bcastshowDESCRIPTION Use this command t
942 Fabric OS Command Reference53-1003108-01psShow2psShowDisplays power supply status. SYNOPSIS psshowDESCRIPTION Use this command to display the curr
Fabric OS Command Reference 94353-1003108-01rasAdmin2rasAdminConfigures RASlog message generation. SYNOPSIS rasadmin --enable [-log MSG-ID] [-syslog M
944 Fabric OS Command Reference53-1003108-01rasAdmin2--set -log MSG-IDChanges the default severity level of the specified message. -severity valueSpec
Fabric OS Command Reference 94553-1003108-01rasAdmin2To display the status and configuration of messages that belong to the specified module: switch:a
946 Fabric OS Command Reference53-1003108-01rasMan2rasManDisplays RASlog message text and documentation. SYNOPSIS rasman message_idrasman --helpDESCRI
Fabric OS Command Reference 94753-1003108-01rasMan2 has been deactivated.MESSAGE TYPE AUDITCLASS FABRICSEVERITY INFOPROBABLE CAUSE
948 Fabric OS Command Reference53-1003108-01reboot2rebootReboots the control processor (CP). SYNOPSIS reboot [-f]DESCRIPTION Use this command to perfo
Fabric OS Command Reference 94953-1003108-01reboot2To reboot a CP on a DCX when HA is enabled: switch:admin> reboot Warning: This command is being
950 Fabric OS Command Reference53-1003108-01relayConfig2relayConfigSets and displays the relay host IP address. SYNOPSIS relayconfig --config -rla_ip
Fabric OS Command Reference 95153-1003108-01roleConfig2roleConfigManages user-defined roles. SYNOPSIS roleconfig --add role_name [-desc description]
70 Fabric OS Command Reference53-1003108-01bladeCfgGeMode2bladeCfgGeModeConfigures a GbE port or a 10GbE port on the Brocade FX8-24 blade. SYNOPSIS bl
952 Fabric OS Command Reference53-1003108-01roleConfig2role_nameSpecifies the name for the role to be created or modified. The name must be unique; it
Fabric OS Command Reference 95353-1003108-01roleConfig2--helpDisplays the command usage.EXAMPLES To create a role with Zoning and SecurityAdmnin permi
954 Fabric OS Command Reference53-1003108-01routeHelp2routeHelpDisplays a list of FSPF-related commands. SYNOPSIS routehelpDESCRIPTION Use this comman
Fabric OS Command Reference 95553-1003108-01rtLogTrace2rtLogTraceManages real-time trace logging. SYNOPSIS rtlogtrace --enablertlogtrace --disablertlo
956 Fabric OS Command Reference53-1003108-01secActiveSize2secActiveSizeDisplays the size of the active security database. SYNOPSIS secactivesizeDESCRI
Fabric OS Command Reference 95753-1003108-01secAuthSecret2secAuthSecretManages the DH-CHAP shared secret key information. SYNOPSIS secauthsecret --sho
958 Fabric OS Command Reference53-1003108-01secAuthSecret2To list the shared secret WWN in Access Gateway mode:switch:admin> secauthsecret --show W
Fabric OS Command Reference 95953-1003108-01secCertUtil2secCertUtilManages certificates on a switch. SYNOPSIS seccertutilseccertutil genkey [-nowarn]
960 Fabric OS Command Reference53-1003108-01secCertUtil2• Import or export a certificate.• Configure a SSL certificate file name.• Enable secure proto
Fabric OS Command Reference 96153-1003108-01secCertUtil2-locality localitySpecifies the city. Provide the full name, for example, "San Jose"
Fabric OS Command Reference 7153-1003108-01bladeCfgGeMode2To display the GbE port mode for all configured slots:switch:admin> bladecfggemode --show
962 Fabric OS Command Reference53-1003108-01secCertUtil2-nowarnDeletes the specified file without confirmation. This operand is optional.exportExports
Fabric OS Command Reference 96353-1003108-01secCertUtil2-fcapcacertImports an FCAP CA certificate.-config cacertImports a CA certificate.-config swcer
964 Fabric OS Command Reference53-1003108-01secCertUtil2EXAMPLES To generate a public/private key pair in interactive mode:switch:admin> seccertuti
Fabric OS Command Reference 96553-1003108-01secCertUtil2To import an LDAP certificate from a remote host to the local switch in interactive mode:switc
966 Fabric OS Command Reference53-1003108-01secCertUtil2To import a PKI-based certificate with configure and enable option in noninteractive mode:swit
Fabric OS Command Reference 96753-1003108-01secCertUtil2To export an FCAP switch CSR in interactive mode:switch:admin> seccertutil export -fcapswcs
968 Fabric OS Command Reference53-1003108-01secCertUtil2To display the content of the CSR one page at a time:switch:admin> seccertutil showcsr | mo
Fabric OS Command Reference 96953-1003108-01secDefineSize2secDefineSizeDisplays the size of the defined security database. SYNOPSIS secdefinesizeDESCR
970 Fabric OS Command Reference53-1003108-01secGlobalShow2secGlobalShowDisplays the current internal security state information. SYNOPSIS secglobalsho
Fabric OS Command Reference 97153-1003108-01secGlobalShow2Zone Size (include enabled configuration) 312 bytesZone sum e04b215bsec_db: freeprimaryDLPha
Comments to this Manuals