Terminal VT100
Boot Configuration
Boot Order
1. Embedded NIC
2. Disk or smart array
Embedded NIC1 Enabled
2.1.8.3 DL160 G6 Servers
IPMI
Serial Port assigned to System
Serial Port Connection Mode Direct
PCI
NIC1 control Enabled
NIC1 PXE Enabled
SATA
SATA#1 Controller Mode AHCI
Boot Configuration
Boot Order
1. NIC
2. CD
3. Disk
2.1.8.4 SL2x170z G6 and DL170h G6 Servers BIOS setting
IMPORTANT: To enable BIOS updates, you must restart the server. You can restart the server
with Ctrl+Alt+Delete immediately after leaving the BIOS, or you can physically restart the server
by using the power switch on the server.
Figure 3 NIC2 on the SL2x170z G6 Server
BIOS settings
Post speedup Enabled