HP Insight Management Agents User Guide Part number: 308447-006 Sixth edition: March 2010
HP Insight Management Agents for Servers 10 NOTE: If you have enabled anonymous access, then you can access the System Management Homepage dis
HP Insight Management Agents for Servers 11 Header frame The header frame is always visible regardless of which tab you are viewing. A link, loc
HP Insight Management Agents for Servers 12 Host Name Displays full computer name of the system. System model The System Model displays the mode
HP Insight Management Agents for Servers 13 Refresh Click on the Refresh link to refresh the System Management Homepage. . Body frame
HP Insight Management Agents for Servers 14 System Status The System Status displays a status icon with a label under it. A specific webapp sets
HP Insight Management Agents for Servers 15 • File system space used • Logical Disks • Processors • Server • Memory • Network • Physical
HP Insight Management Agents for Servers 16 SNMP Webagent The HP Management Agents page is used to view and set the HP Management Agents confi
HP Insight Management Agents for Servers 17 Management HTTP Server section The Management HTTP Server section provides links allowing you to con
HP Insight Management Agents for Servers 18 Certificate selected, and leave the list of trusted systems empty by not importing certificates. HP s
HP Insight Management Agents for Servers 19 Logs tab The Logs tab includes various log information like Integrated Management Log, HP Version
2 Legal notices © Copyright 2010 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. Th
HP Insight Management Agents for Servers 20 Support tab The Support tab contains of links to available support services like – ProLiant Essentia
Agent information 21 2 Agent information Management Host agent The Management Host agent gathers data for the HP Host OS MIB. This data includes:
Agent information 22 System Agent Software version information The software version section displays the versions of the system software installe
Agent information 23 • Client/Internal—The network is used to connect client systems and for internal cluster communication. • None—The network
Agent information 24 • Orring Diode Failed • Brownout • Give Up On Startup • NVRAM Invalid • Calibration Table Invalid • If the power suppl
Agent information 25 NOTE: A Failed condition does not occur in a client PC since the power supply for the client is cut off if thermal conditi
Agent information 26 • Disabled—ECC memory correction is supported, but errors are not logged for this device. • When a certain rate of errors
Agent information 27 • Mirroring—This system is configured for Mirrored Memory Protection. All memory banks are duplicated in Mirrored Memory, a
Agent information 28 • Other—Memory type can not be determined. • Board—The value determine the memory module is permanently mounted (not modu
Agent information 29 Management Processor Integrated Lights-Out (iLO) NIC The NIC section displays the following information about the NIC in the
Contents 3 Contents 1 HP Insight Management Agents for Servers…………………………………………………………………………5 Browser requirements ...
Agent information 30 • Pending Alarm—Displays if the alert is unable to determine the state of the iLO, or if all alerts have been delivered or
Agent information 31 Self Test Results The Self Test Results section indicates various error-status depending on the Remote Insight model. The f
Agent information 32 Select Reset to Original Values to return to the original threshold values, or the values from the last time the thresholds
Agent information 33 interrupts and DPCs. A high rate of privileged time might be attributable to many interrupts generated by a failing device.
Agent information 34 • Context Block Queue/sec—Rate per second at which the work context blocks must be placed on the FSP queue of the server to
Agent information 35 Nonpaged Bytes, so it might not equal Process: Pool Nonpaged Bytes: _Total. This counter displays the last observed value o
Agent information 36 • Page Faults/sec—Rate at which the page faults occur in the executing threads within this process. A page fault occurs whe
Agent information 37 • Firmware Primary/Secondary—The array controller is using a primary/secondary algorithm implemented in the controller firm
Agent information 38 • High—Indicates the rebuild priority is high. • Unknown—Indicates that the rebuild priority is not recognized. You may ne
Agent information 39 Extension, and Migration are temporarily suspended until the backup power source is fully charged. Array accelerator operati
Contents 4 3 Subsystem specific to a NetWare operating system………………………………………………………………80 Operating system overview ...
Agent information 40 • Redundant Size Mismatch—Cache operations are temporarily disabled. The cache sizes on the redundant controllers do not ma
Agent information 41 • Read Errors—Displays the total number of read memory parity errors that were detected while reading from the Array Accele
Agent information 42 • Model—Displays a description of the physical drive. The text depends on the manufacturer of the drive and the drive type.
Agent information 43 • Unknown—The Storage Agents cannot determine the drive type. • Media Type—Indicates the type of media the physical drive
Agent information 44 IMPORTANT: The Start or Stop button only be appears if you are logged on as an administrator or an operator, SNMP Sets are
Agent information 45 • Used Realloc—Displays the number of sectors of the reallocation area that have been used by the physical drive. The statu
Agent information 46 • Check the physical proximity of the system to other electrical devices. Since electrical noise may cause a Bus Fault erro
Agent information 47 If the number of hardware errors is not zero and the drive has failed, replace the drive. If the counter is not zero and the
Agent information 48 • Recovered Write Errors—Displays the number of write errors corrected through physical drive retries or recovered by a phy
Agent information 49 • Rebuild Blocks Left—Displays the number of blocks of data that still need to be redistributed. When the value reaches 0,
HP Insight Management Agents for Servers 5 1 HP Insight Management Agents for Servers The HP System Management Homepage version 8.25 and later ac
Agent information 50 • Sectors Written—Displays the number of sectors written for the logical volume for this interval. This value is expressed
Agent information 51 • Ultra3—The current data transfer speed for this tape library is 80 million transfers per second. • Unknown—The agent is
Agent information 52 • Narrow (8 bits)—The negotiated data transfer width for this drive is narrow (8 data bits). • Wide (16 bits)—The negotiat
Agent information 53 • Rewrites—Displays the number of times blocks that had to be rewritten to the device. This value is maintained since the T
Agent information 54 • SAS Attached—This chassis is attached to the server with a SAS cable. • Unknown—The Storage Agents are unable to determi
Agent information 55 • IDE ATA disk drives • IDE ATA logical drives IDE controller information Select a controller entry from the Mass Storage
Agent information 56 • Serial Number—Displays the serial number of the disk drive. • Firmware Revision—Displays the firmware version of the dis
Agent information 57 • Unknown—The agent cannot determine the RAID level of this logical drive. You might need to upgrade your software. • Capa
Agent information 58 • Firmware Version—Displays the SCSI controller’s BIOS firmware version number. This information is not available for all S
Agent information 59 • Degraded—Indicates that the library has degraded in some manner. • Failed—Indicates that the library has failed and can
HP Insight Management Agents for Servers 6 Obtaining JVM from HP.com Java support for Internet Explorer can be downloaded from http://www.hp.com/
Agent information 60 • OK—Indicates the tape drive is operating normally. • Failed—Indicates the tape drive has failed and might need to be rep
Agent information 61 Having a large number of retry corrected errors does not necessarily indicate that the drive is failing. However, as a preca
Agent information 62 • Unknown—The Storage Agents do not recognize the drive enclosure. You might need to upgrade your software. • Vendor—Displ
Agent information 63 • Not Configured—The physical drive is not configured. Ensure that all of the drive switches are properly set. • Bad Cable
Agent information 64 • Used Reallocs—Displays the number of sectors of the reallocation area that have been used by the physical drive. Because
Agent information 65 NOTE: If sectors read and written are always zero or N/A on Microsoft Windows 2000 you must install Service Pack 2 or high
Agent information 66 SCSI logical drives Select a SCSI logical drive from the SCSI controller submenu to display the following information. The f
Agent information 67 Spare drives A list of spare drives that can be used by this logical drive to replace a failed drive. Select one of the list
Agent information 68 NOTE: If the current data transfer width is Narrow (8 bits) then the speed in megabytes per second is equal to the million
Agent information 69 Use the ASR Reset Limit feature in conjunction with the ASR Reset Count feature in the same window. The ASR Reset Count feat
HP Insight Management Agents for Servers 7 Security The HP Insight Management Agents allow SNMP sets for some system parameters. This capability
Agent information 70 • Serial Number—Displays the Physical serial number of the device or client system board. Use this number for identificatio
Agent information 71 • Other—The system does not support Advanced Memory Protection or the Management Agent cannot determine the status. • Not
Agent information 72 • Advanced Memory Protection Condition—displays the current condition of the Advanced Memory Protection subsystem. The foll
Agent information 73 • FPM (Fast-Page Mode) • EDO (Extended Data Out) • BEDO (Burst Extended Data Out) • Synch DRAM (Synchronous DRAM) • Unk
Agent information 74 • Monitor Serial Number displays the serial number for the monitor. Use this number for identification purposes. • Monitor
Agent information 75 • Enclosure Model • Asset Tag • Part Number • Spare Pat Number • Serial Number • Firmware Revision • Previous Enclosu
Agent information 76 Namespace: root\default Object Class: CPQ_System_Performance Subclasses: • CPQ_System • ContextSwitchRate • CpqQueueLengt
Agent information 77 • DiskWriteBytesPersec • DiskWritesPersec • PhysicalDisk • CPQ_LogicalDisk • DiskQueueLength • DiskTimePercent • Free
Agent information 78 IMPORTANT: To mark entries as corrected, the agents must have sets enabled and the SNMP Community string must be correct.
Agent information 79 • Server Manager Failure—An error occurred in the server interface with the Server Manager. • UPS A/C Line Failure/Shutdow
HP Insight Management Agents for Servers 8 • The WEBAGENT.INI file is located in the directory /var/opt/CPQIMddd/web/im/webagent if the pathname
Subsystem specific to a NetWare operating system 80 3 Subsystem specific to a NetWare operating system Operating system overview HP now provides
Subsystem specific to a NetWare operating system 81 File System page The File System page provides the file system information for the server. Th
Subsystem specific to a NetWare operating system 82 General information The General Information section displays the following information: • Us
Subsystem specific to a NetWare operating system 83 • Memory (bytes) (sortable)—The total memory, in bytes, used by the NLM. This value is a com
Subsystem specific to a NetWare operating system 84 • InwDos • Other • Description (sortable)—A brief description of this partition. • Size (
CR3500 RAID Array SCSI controller 85 4 CR3500 RAID Array SCSI controller Mass storage RAID Array This section displays RAID array information. Fi
CR3500 RAID Array SCSI controller 86 • Formatting—The drive is currently being formatted. • Action—Provides a brief description of an action yo
CR3500 RAID Array SCSI controller 87 • Critical—The controller temperature sensor has detected a critical temperature condition in the primary e
Where to go for additional help 88 5 Where to go for additional help In addition to this guide, the following information sources are available:
Appendix A Troubleshooting 89 Appendix A Troubleshooting Insight Management Agents for Servers issues Inability to perform remote reboot on a ser
HP Insight Management Agents for Servers 9 administrators if the file system enables it. For private key security reasons, HP recommends that the
Appendix A Troubleshooting 90 When attempting to browse to Web-Enabled System Management software on port 2381, the system is not accessible beca
Appendix A Troubleshooting 91 d. Click Reset>OK. • There are known browser issues in the Management Agents for Tru64 UNIX. However, many hav
Appendix A Troubleshooting 92 4. Click OK. When prompted to restart the Management Agents, click Yes. Insight Manager cannot manage a system If
Appendix A Troubleshooting 93 NOTE: The HP Diagnostics utility initializes physical drives attached to HP Drive Arrays. Disk Subsystem button
Appendix A Troubleshooting 94 The HP Foundation Agents service could not terminate agent "CPQMHOST." The data contains the error code.
Appendix A Troubleshooting 95 System restart to disk-based utilities fails for NetWare If you click Reboot on the Insight Manager display, and se
Glossary 96 Glossary Automatic Server Recovery (ASR) A server feature designed to automatically restart the server after a critical hardware or s
Glossary 97 Simple Network Management Protocol (SNMP) SNMP defines a set of commands that a management application uses to retrieve or change the
Index 98 Index A accounts, user, 8 Adapter Information Page, 83 array controllers, 84 ASR POST failure, 93 B browser, 89 browser requirements, 5
Index 99 software, cluster, 23 spare drives: RAID Array, 84 subsystem button, disabled, 92 Summary Page, 79 System Management Homepage, 9, 11 sys