Hp Insight Management Agents User Manual

Browse online or download User Manual for Software Hp Insight Management Agents. HP Insight Management Agents User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 99
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
HP Insight Management Agents
User Guide
Part number: 308447-006
Sixth edition: March 2010
Page view 0
1 2 3 4 5 6 ... 98 99

Summary of Contents

Page 1 - HP Insight Management Agents

HP Insight Management Agents User Guide Part number: 308447-006 Sixth edition: March 2010

Page 2

HP Insight Management Agents for Servers 10 NOTE: If you have enabled anonymous access, then you can access the System Management Homepage dis

Page 3 - Contents

HP Insight Management Agents for Servers 11 Header frame The header frame is always visible regardless of which tab you are viewing. A link, loc

Page 4 - Contents 4

HP Insight Management Agents for Servers 12 Host Name Displays full computer name of the system. System model The System Model displays the mode

Page 5 - Browser requirements

HP Insight Management Agents for Servers 13 Refresh Click on the Refresh link to refresh the System Management Homepage. . Body frame

Page 6 - Obtaining JVM from Sun

HP Insight Management Agents for Servers 14 System Status The System Status displays a status icon with a label under it. A specific webapp sets

Page 7

HP Insight Management Agents for Servers 15 • File system space used • Logical Disks • Processors • Server • Memory • Network • Physical

Page 8 - Overview

HP Insight Management Agents for Servers 16 SNMP Webagent The HP Management Agents page is used to view and set the HP Management Agents confi

Page 9 - Logging in

HP Insight Management Agents for Servers 17 Management HTTP Server section The Management HTTP Server section provides links allowing you to con

Page 10 - System Management Homepage

HP Insight Management Agents for Servers 18 Certificate selected, and leave the list of trusted systems empty by not importing certificates. HP s

Page 11 - Header frame

HP Insight Management Agents for Servers 19 Logs tab The Logs tab includes various log information like Integrated Management Log, HP Version

Page 12

2 Legal notices © Copyright 2010 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. Th

Page 13 - Home tab

HP Insight Management Agents for Servers 20 Support tab The Support tab contains of links to available support services like – ProLiant Essentia

Page 14

Agent information 21 2 Agent information Management Host agent The Management Host agent gathers data for the HP Host OS MIB. This data includes:

Page 15 - Settings tab

Agent information 22 System Agent Software version information The software version section displays the versions of the system software installe

Page 16 - SNMP Webagent

Agent information 23 • Client/Internal—The network is used to connect client systems and for internal cluster communication. • None—The network

Page 17 - Security

Agent information 24 • Orring Diode Failed • Brownout • Give Up On Startup • NVRAM Invalid • Calibration Table Invalid • If the power suppl

Page 18 - Tasks Tab

Agent information 25 NOTE: A Failed condition does not occur in a client PC since the power supply for the client is cut off if thermal conditi

Page 19 - Webapps tab

Agent information 26 • Disabled—ECC memory correction is supported, but errors are not logged for this device. • When a certain rate of errors

Page 20 - Help tab

Agent information 27 • Mirroring—This system is configured for Mirrored Memory Protection. All memory banks are duplicated in Mirrored Memory, a

Page 21 - 2 Agent information

Agent information 28 • Other—Memory type can not be determined. • Board—The value determine the memory module is permanently mounted (not modu

Page 22 - System Agent

Agent information 29 Management Processor Integrated Lights-Out (iLO) NIC The NIC section displays the following information about the NIC in the

Page 23 - Sub system Classification

Contents 3 Contents 1 HP Insight Management Agents for Servers…………………………………………………………………………5 Browser requirements ...

Page 24 - Cooling and temperature

Agent information 30 • Pending Alarm—Displays if the alert is unable to determine the state of the iLO, or if all alerts have been delivered or

Page 25 - Agent information 25

Agent information 31 Self Test Results The Self Test Results section indicates various error-status depending on the Remote Insight model. The f

Page 26 - Agent information 26

Agent information 32 Select Reset to Original Values to return to the original threshold values, or the values from the last time the thresholds

Page 27 - Memory Details

Agent information 33 interrupts and DPCs. A high rate of privileged time might be attributable to many interrupts generated by a failing device.

Page 28 - PCI Devices

Agent information 34 • Context Block Queue/sec—Rate per second at which the work context blocks must be placed on the FSP queue of the server to

Page 29 - Management Processor

Agent information 35 Nonpaged Bytes, so it might not equal Process: Pool Nonpaged Bytes: _Total. This counter displays the last observed value o

Page 30 - Modem/COM Port Settings

Agent information 36 • Page Faults/sec—Rate at which the page faults occur in the executing threads within this process. A page fault occurs whe

Page 31 - Operating System

Agent information 37 • Firmware Primary/Secondary—The array controller is using a primary/secondary algorithm implemented in the controller firm

Page 32 - Logical Disk Space

Agent information 38 • High—Indicates the rebuild priority is high. • Unknown—Indicates that the rebuild priority is not recognized. You may ne

Page 33 - Server

Agent information 39 Extension, and Migration are temporarily suspended until the backup power source is fully charged. Array accelerator operati

Page 34 - Agent information 34

Contents 4 3 Subsystem specific to a NetWare operating system………………………………………………………………80 Operating system overview ...

Page 35 - Processes

Agent information 40 • Redundant Size Mismatch—Cache operations are temporarily disabled. The cache sizes on the redundant controllers do not ma

Page 36 - Processor Utilization

Agent information 41 • Read Errors—Displays the total number of read memory parity errors that were detected while reading from the Array Accele

Page 37 - Agent information 37

Agent information 42 • Model—Displays a description of the physical drive. The text depends on the manufacturer of the drive and the drive type.

Page 38 - Agent information 38

Agent information 43 • Unknown—The Storage Agents cannot determine the drive type. • Media Type—Indicates the type of media the physical drive

Page 39 - Agent information 39

Agent information 44 IMPORTANT: The Start or Stop button only be appears if you are logged on as an administrator or an operator, SNMP Sets are

Page 40 - Agent information 40

Agent information 45 • Used Realloc—Displays the number of sectors of the reallocation area that have been used by the physical drive. The statu

Page 41 - Physical Drive Information

Agent information 46 • Check the physical proximity of the system to other electrical devices. Since electrical noise may cause a Bus Fault erro

Page 42 - Agent information 42

Agent information 47 If the number of hardware errors is not zero and the drive has failed, replace the drive. If the counter is not zero and the

Page 43 - Identify Drive

Agent information 48 • Recovered Write Errors—Displays the number of write errors corrected through physical drive retries or recovered by a phy

Page 44 - Logical Drive Information

Agent information 49 • Rebuild Blocks Left—Displays the number of blocks of data that still need to be redistributed. When the value reaches 0,

Page 45 - Problem Indicators

HP Insight Management Agents for Servers 5 1 HP Insight Management Agents for Servers The HP System Management Homepage version 8.25 and later ac

Page 46 - Failure Indicators

Agent information 50 • Sectors Written—Displays the number of sectors written for the logical volume for this interval. This value is expressed

Page 47 - Statistics

Agent information 51 • Ultra3—The current data transfer speed for this tape library is 80 million transfers per second. • Unknown—The agent is

Page 48

Agent information 52 • Narrow (8 bits)—The negotiated data transfer width for this drive is narrow (8 data bits). • Wide (16 bits)—The negotiat

Page 49 - Agent information 49

Agent information 53 • Rewrites—Displays the number of times blocks that had to be rewritten to the device. This value is maintained since the T

Page 50

Agent information 54 • SAS Attached—This chassis is attached to the server with a SAS cable. • Unknown—The Storage Agents are unable to determi

Page 51 - Tape Drive Information

Agent information 55 • IDE ATA disk drives • IDE ATA logical drives IDE controller information Select a controller entry from the Mass Storage

Page 52 - Agent information 52

Agent information 56 • Serial Number—Displays the serial number of the disk drive. • Firmware Revision—Displays the firmware version of the dis

Page 53 - Storage Systems

Agent information 57 • Unknown—The agent cannot determine the RAID level of this logical drive. You might need to upgrade your software. • Capa

Page 54 - IDE controllers

Agent information 58 • Firmware Version—Displays the SCSI controller’s BIOS firmware version number. This information is not available for all S

Page 55 - IDE ATA disk drives

Agent information 59 • Degraded—Indicates that the library has degraded in some manner. • Failed—Indicates that the library has failed and can

Page 56 - IDE ATA logical drives

HP Insight Management Agents for Servers 6 Obtaining JVM from HP.com Java support for Internet Explorer can be downloaded from http://www.hp.com/

Page 57 - Controller information

Agent information 60 • OK—Indicates the tape drive is operating normally. • Failed—Indicates the tape drive has failed and might need to be rep

Page 58 - Tape library

Agent information 61 Having a large number of retry corrected errors does not necessarily indicate that the drive is failing. However, as a preca

Page 59 - Tape devices

Agent information 62 • Unknown—The Storage Agents do not recognize the drive enclosure. You might need to upgrade your software. • Vendor—Displ

Page 60 - Agent information 60

Agent information 63 • Not Configured—The physical drive is not configured. Ensure that all of the drive switches are properly set. • Bad Cable

Page 61 - CD-ROM drive information

Agent information 64 • Used Reallocs—Displays the number of sectors of the reallocation area that have been used by the physical drive. Because

Page 62 - SCSI physical drives

Agent information 65 NOTE: If sectors read and written are always zero or N/A on Microsoft Windows 2000 you must install Service Pack 2 or high

Page 63 - Drive indicators

Agent information 66 SCSI logical drives Select a SCSI logical drive from the SCSI controller submenu to display the following information. The f

Page 64 - Drive statistics

Agent information 67 Spare drives A list of spare drives that can be used by this logical drive to replace a failed drive. Select one of the list

Page 65 - Statistics Preserved

Agent information 68 NOTE: If the current data transfer width is Narrow (8 bits) then the speed in megabytes per second is equal to the million

Page 66 - SCSI logical drives

Agent information 69 Use the ASR Reset Limit feature in conjunction with the ASR Reset Count feature in the same window. The ASR Reset Count feat

Page 67 - SCSI bus information

HP Insight Management Agents for Servers 7 Security The HP Insight Management Agents allow SNMP sets for some system parameters. This capability

Page 68 - System Configuration

Agent information 70 • Serial Number—Displays the Physical serial number of the device or client system board. Use this number for identificatio

Page 69 - System Board

Agent information 71 • Other—The system does not support Advanced Memory Protection or the Management Agent cannot determine the status. • Not

Page 70 - Advanced Memory Protection

Agent information 72 • Advanced Memory Protection Condition—displays the current condition of the Advanced Memory Protection subsystem. The foll

Page 71 - Agent information 71

Agent information 73 • FPM (Fast-Page Mode) • EDO (Extended Data Out) • BEDO (Burst Extended Data Out) • Synch DRAM (Synchronous DRAM) • Unk

Page 72 - General I/O Devices

Agent information 74 • Monitor Serial Number displays the serial number for the monitor. Use this number for identification purposes. • Monitor

Page 73 - System Summery

Agent information 75 • Enclosure Model • Asset Tag • Part Number • Spare Pat Number • Serial Number • Firmware Revision • Previous Enclosu

Page 74 - Enclosure Information

Agent information 76 Namespace: root\default Object Class: CPQ_System_Performance Subclasses: • CPQ_System • ContextSwitchRate • CpqQueueLengt

Page 75 - Agent information 75

Agent information 77 • DiskWriteBytesPersec • DiskWritesPersec • PhysicalDisk • CPQ_LogicalDisk • DiskQueueLength • DiskTimePercent • Free

Page 76 - Agent information 76

Agent information 78 IMPORTANT: To mark entries as corrected, the agents must have sets enabled and the SNMP Community string must be correct.

Page 77 - Critical Error Log

Agent information 79 • Server Manager Failure—An error occurred in the server interface with the Server Manager. • UPS A/C Line Failure/Shutdow

Page 78 - Agent information 78

HP Insight Management Agents for Servers 8 • The WEBAGENT.INI file is located in the directory /var/opt/CPQIMddd/web/im/webagent if the pathname

Page 79 - Integrated Management Log

Subsystem specific to a NetWare operating system 80 3 Subsystem specific to a NetWare operating system Operating system overview HP now provides

Page 80 - Summary page

Subsystem specific to a NetWare operating system 81 File System page The File System page provides the file system information for the server. Th

Page 81 - File System page

Subsystem specific to a NetWare operating system 82 General information The General Information section displays the following information: • Us

Page 82 - Loaded NLMs page

Subsystem specific to a NetWare operating system 83 • Memory (bytes) (sortable)—The total memory, in bytes, used by the NLM. This value is a com

Page 83 - Physical Partition page

Subsystem specific to a NetWare operating system 84 • InwDos • Other • Description (sortable)—A brief description of this partition. • Size (

Page 84 - Adapter Information page

CR3500 RAID Array SCSI controller 85 4 CR3500 RAID Array SCSI controller Mass storage RAID Array This section displays RAID array information. Fi

Page 85 - Mass Storage Physical

CR3500 RAID Array SCSI controller 86 • Formatting—The drive is currently being formatted. • Action—Provides a brief description of an action yo

Page 86 - Environment Monitoring Unit

CR3500 RAID Array SCSI controller 87 • Critical—The controller temperature sensor has detected a critical temperature condition in the primary e

Page 87 - External Expansion Cabinet

Where to go for additional help 88 5 Where to go for additional help In addition to this guide, the following information sources are available:

Page 88 - Telephone numbers

Appendix A Troubleshooting 89 Appendix A Troubleshooting Insight Management Agents for Servers issues Inability to perform remote reboot on a ser

Page 89 - Appendix A Troubleshooting

HP Insight Management Agents for Servers 9 administrators if the file system enables it. For private key security reasons, HP recommends that the

Page 90

Appendix A Troubleshooting 90 When attempting to browse to Web-Enabled System Management software on port 2381, the system is not accessible beca

Page 91 - issues

Appendix A Troubleshooting 91 d. Click Reset>OK. • There are known browser issues in the Management Agents for Tru64 UNIX. However, many hav

Page 92 - Insight Manager issues

Appendix A Troubleshooting 92 4. Click OK. When prompted to restart the Management Agents, click Yes. Insight Manager cannot manage a system If

Page 93

Appendix A Troubleshooting 93 NOTE: The HP Diagnostics utility initializes physical drives attached to HP Drive Arrays. Disk Subsystem button

Page 94 - Other problems

Appendix A Troubleshooting 94 The HP Foundation Agents service could not terminate agent "CPQMHOST." The data contains the error code.

Page 95

Appendix A Troubleshooting 95 System restart to disk-based utilities fails for NetWare If you click Reboot on the Insight Manager display, and se

Page 96 - Glossary

Glossary 96 Glossary Automatic Server Recovery (ASR) A server feature designed to automatically restart the server after a critical hardware or s

Page 97 - Glossary 97

Glossary 97 Simple Network Management Protocol (SNMP) SNMP defines a set of commands that a management application uses to retrieve or change the

Page 98

Index 98 Index A accounts, user, 8 Adapter Information Page, 83 array controllers, 84 ASR POST failure, 93 B browser, 89 browser requirements, 5

Page 99

Index 99 software, cluster, 23 spare drives: RAID Array, 84 subsystem button, disabled, 92 Summary Page, 79 System Management Homepage, 9, 11 sys

Comments to this Manuals

No comments