8Δ26 Removal and Replacement
C3187Δ90000
Parameters Printed Below EEROM Text Block (Decimal Values)
Number of Power Cycles ξNumber of times plotter has been switched on.ξ
Number of Pages Printed
Number of Bail Lifts
Number of Bail Errors
Number of System Errors
Last System Error
ξSee System Errors earlier in this chapter for correspondence of numbers to errors.ξ
Last System Error Data
Bail Up Position Offset ξCalculated during bail calibration.ξ
Bench Run ξWhether the bench run has been performed or not.ξ
Bench Run Maximum YΔAxis PWM ξYΔaxis = carriage axis.ξ
Bench Run Maximum XΔAxis PWM ξXΔaxis = media axis.ξ
Encoder Tests Maximum YΔAxis PWM
Encoder Tests Maximum XΔAxis PWM
Last XΔAxis Calibration ξXΔaxis calibration = accuracy calibrationξ
Factory Calibration Factor
ξThis is the driveΔroller correction factor, calculated during accuracy calibration.ξ
Setup Sheet LED Calibration formula.
ξThe values in the formula are calculated during the setupΔsheet calibration.ξ
Reading the EEROM Text Block
The contents of the EEROM integrated circuit are printed in hexadecimal form in a text
block on the service configuration plot.
To read the EEROM text block, perform the following procedure:
, Examine the EEROM memory map in Table 8Δ1 to find the memory address of the data
you want to read.
. Use the memory location key in Table 8Δ2 to locate the position of the memory address on
the service configuration plot.
A Read the contents of the memory address from the service configuration plot.
Example: Searching for the mediaΔsensor correction factor
1 The EEROM memory map ξTable 8Δ1ξ indicates that the memory address of the
mediaΔsensor correction factor is 1b.
2 The memory location key ξTable 8Δ2ξ indicates that address 1b is located in the second row
from the top, in the fifth column from the right.
3 On the sample EEROM text block ξTable 8Δ3ξ, address 1b contains the number 0.
Therefore, in this case, the mediaΔsensor correction factor is hexadecimal 0 ξ= decimal 0ξ.