HP d325 ST User Manual Page 15

  • Download
  • Add to my manuals
  • Print
  • Page
    / 48
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 14
Keyboard-less Operation
The system can be operated without a keyboard
Yes Yes
Remote ROM Flash
Provides secure, fail-safe ROM image management from a
central network console
Yes Yes
Remote Wakeup / Remote
Shutdown
Allow a system administrator to power on, restart, and
power off a client computer from a remote location.
This enables cost-effective power consumption when the
administrator needs to distribute software, perform
security management, or update the ROM.
Yes Yes
ROM Based Setup (F10)
and Start-up Diagnostics
-----
Yes Yes
System Environmental
System EnvironmentalSystem Environmental
System Environmental
Specs
SpecsSpecs
Specs
Description
DescriptionDescription
Description
Microtower
MicrotowerMicrotower
Microtower
Slim Tower
Slim TowerSlim Tower
Slim Tower
Acoustics: Advanced
Power Management – On
Seated operator position
Idle (Hard drive
spinning but not
seeking) = 23 dBA
Idle (Hard drive
spinning but not
seeking) = 27 dBA
Shock
Operating
(*Using 11-ms half-sine
shock pulse)
-----
5 G's* (with no
damage being
incurred)
5 G's* (with no
damage being
incurred)
Non-Operating
(*Using 11-ms half-sine
shock pulse)
-----
10 G's*, positive
and negative
directions front to
back axis: 20 G's*
in all other axes
10 G's*, positive
and negative
directions front to
back axis: 20 G's*
in all other axess
Vibration
Operating
-----
Random vibration
at 0.000215
G²/Hz, 10Hz to
300Hz, (0.25G's
nominal)
Random vibration
at 0.000215
G²/Hz, 10Hz to
300Hz, (0.25G's
nominal)
Non-Operating
-----
Random vibration
at 0.0005 G²/Hz,
10Hz to 500Hz,
(0.5G's nominal)
Random vibration
at 0.0005 G²/Hz,
10Hz to 500Hz,
(0.5G's nominal)
Relative Humidity
Operating
(maximum wet bulb temp.,
non-condensing)
-----
10% to 90%
relative humidity
(Rh), 28°C
10% to 90%
relative humidity
(Rh), 28°C
Non-operating
(maximum wet bulb temp.,
non-condensing)
-----
5% to 95% relative
humidity (Rh),
38.7°C
5% to 95% relative
humidity (Rh),
38.7°C
Altitude Max (un-
pressurized)
Operating
(Maximum allowable
altitude change rate is
1500 ft/min.)
-----
0 to 10,000 feet
(3,048 meters) –
This value may be
limited by the type
and number of
options installed.
0 to 10,000 feet
(3,048 meters) –
This value may be
limited by the type
and number of
options installed.
QuickSpecs
HP Business Desktop d325 Series
HP Business Desktop d325 SeriesHP Business Desktop d325 Series
HP Business Desktop d325 Series
Standard Features - Base Unit Details
DA - 11642 North America — Version 24 — August 23, 2005
Page 15
Page view 14
1 2 ... 10 11 12 13 14 15 16 17 18 19 20 ... 47 48

Comments to this Manuals

No comments