HP ProLiant DL585 G2 User Manual

Browse online or download User Manual for PC/workstation barebones HP ProLiant DL585 G2. HP ProLiant DL585 Generation 2 (G2) [de] [es] [fr] [nl]

  • Download
  • Add to my manuals
  • Print
  • Page
    / 46
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
1. Hot Plug Redundant Fans (standard)
2. System Insight Display
3. Hot Plug Redundant Fans (standard)
4. 1.44 MB Diskette Drive (optional)
5. DVD/CD-RW drive (standard)
6. Front Panel LED Display (internal and external health, Unit ID
light) and Power Button
7. Two USB ports
8. One video port
9. Front accessible processor / memory cage
10. Eight bay Small Form Factor (SFF) Serial Attached SCSI (SAS)
drive cage
11. 4U (7" Height) Rack Form Factor
12. Hot Plug Redundant Power Supply
13. Nine PCI I/O Slots (2 64-bit/100MHz PCI-X, 4 PCI-Express
x4, 3 PCI-Express x8)
14. Hot Plug Redundant Power Supply
15. Removable Top Access Panel
QuickSpecs
HP ProLiant DL585 Generation 2 (G2)
HP ProLiant DL585 Generation 2 (G2)HP ProLiant DL585 Generation 2 (G2)
HP ProLiant DL585 Generation 2 (G2)
Overview
DA - 12575 Worldwide — Version 10 — November 27, 2006
Page 1
Page view 0
1 2 3 4 5 6 ... 45 46

Summary of Contents

Page 1 - QuickSpecs

1. Hot Plug Redundant Fans (standard)2. System Insight Display3. Hot Plug Redundant Fans (standard)4. 1.44 MB Diskette Drive (optional)5. DVD/CD-RW dr

Page 2

OS SupportOS SupportOS SupportOS SupportWindows Server 2003Red Hat Enterprise LinuxSuSE Linux Enterprise ServerSun SolarisVMware Virtualization Softwa

Page 3

Factory Express PortfolioFactory Express PortfolioFactory Express PortfolioFactory Express Portfoliofor Servers and Storagefor Servers and Storagefor

Page 4

resolution.6-Hour Call to Repair, On-site Service, 7-Day x 24-Hour Coverage, 3 YearsTotal Care – Highest HP Support service level recommend to help in

Page 5

SolutionsSolutionsSolutionsSolutionsDesigned for enterprise customers with growing data centers and application and Internet serviceproviders that req

Page 6

ModelsModelsModelsModels DL585R02 O2.8GHz-DL585R02 O2.8GHz-DL585R02 O2.8GHz-DL585R02 O2.8GHz-1MB, 8GB1MB, 8GB1MB, 8GB1MB, 8GB (4P Dual-Core)413930-xx1

Page 7

DL585R02 O2.4 GHz-DL585R02 O2.4 GHz-DL585R02 O2.4 GHz-DL585R02 O2.4 GHz-1MB, 2GB1MB, 2GB1MB, 2GB1MB, 2GB (2P Dual-core)413928-xx1Processor(s)Processor

Page 8

NOTE: NOTE: NOTE: NOTE: For Configure to Order requirements within EMEA region, please consult local Sales Contact.NOTE: NOTE: NOTE: NOTE: HP does not

Page 9

Optical DrivesOptical DrivesOptical DrivesOptical DrivesSlimline CD-RW/DVD-ROM 24X Combo Drive Option Kit331903-B21Slimline DVD-ROM Drive (8X/24X) Opt

Page 10

NOTE:NOTE:NOTE:NOTE: Some options may not be factory integratable. Please contact your local sales representative foradditional information. HP ProLia

Page 11

NOTE:NOTE:NOTE:NOTE: For additional ProLiant Essentials Rapid Deployment Pack License Kits pleasesee the QuickSpecs at:http://h18000.www1.hp.com/produ

Page 12

At A GlanceAt A GlanceAt A GlanceAt A GlanceThe HP ProLiant DL585 G2, the best price/ performance x86 4-processor server in the industry, now supports

Page 13

ProcessorsProcessorsProcessorsProcessorsAMD Opteron Processor 8220SE, 2P Dual-Core (2.8 GHz, 120 Watts) Option Kit413934-B21AMD Opteron Processor 8218

Page 14

Ultra320 Expansion Module for SA-6402273911-B2164-Bit/133-MHz Single Channel Ultra320 SCSI HBA G2374654-B21SCSI HBASCSI HBASCSI HBASCSI HBAHP SC11Xe H

Page 15

CommunicationsCommunicationsCommunicationsCommunicationsHP NC150T PCI 4-port Gigabit 1000T Combo Switch Adapter367132-B21HP NC310F PCI-X 1000SX Gigabi

Page 16

HP StorageWorks Ultrium 232 Internal Tape Drive (Carbonite)NOTE: NOTE: NOTE: NOTE: HP recommends combining this tape drive with the 1U SCSI Rack-Mount

Page 17

Tape AutoloadersTape AutoloadersTape AutoloadersTape AutoloadersHP StorageWorks DAT AutoloaderHP StorageWorks DAT AutoloaderHP StorageWorks DAT Autolo

Page 18

HP Data Protector ExpressHP Data Protector ExpressHP Data Protector ExpressHP Data Protector ExpressSoftwareSoftwareSoftwareSoftwareHP DP Express Back

Page 19

StorageWorks OptionsStorageWorks OptionsStorageWorks OptionsStorageWorks OptionsNOTE:NOTE:NOTE:NOTE: The following is a list of all Fibre Channel Host

Page 20

HP StorageWorksHP StorageWorksHP StorageWorksHP StorageWorksModular Smart ArrayModular Smart ArrayModular Smart ArrayModular Smart Array10001000100010

Page 21

HP 7.3kVA S1132 Monitored PDU – single input, 1U, 32A (INTL)NOTE:NOTE:NOTE:NOTE: Replaces non-RoHs compliant part number 370966-B31.AF510AHP Monitored

Page 22

HP Rack 5000 SeriesHP Rack 5000 SeriesHP Rack 5000 SeriesHP Rack 5000 Series(Graphite Metallic)HP 5642 Rack-Unassembled358254-B21NOTE:NOTE:NOTE:NOTE:

Page 23

ProcessorProcessorProcessorProcessorTwo or four of thefollowing depending onModelAMD Opteron Processor 8220SE, Dual-Core (2.8 GHz, 120 Watts)NOTE: NOT

Page 24

NOTE:NOTE:NOTE:NOTE: Please see the Rack 10000 QuickSpecs for additional options and TechnicalSpecifications such as height, width, depth, weight, and

Page 25

HP KVM Switch OptionsHP KVM Switch OptionsHP KVM Switch OptionsHP KVM Switch Options2x1x16 IP Console Switch with Virtual MediaAF601A4x1x16 IP Console

Page 26

Service and SupportService and SupportService and SupportService and SupportOfferings Offerings Offerings Offerings (HP Care PackServices)Hardware Ser

Page 27

NOTE: NOTE: NOTE: NOTE: Memory configurations listed do not apply to "Factory Integrated Models."HP ProLiant DL585 G2 2P ModelsHP ProLiant D

Page 28

1111(Slotfurthestfromprocessor)2222 3333 4444 5555 6666 77778888(Slot closesttoprocessor)Processor 1 Memory BusProcessor 1 Memory BusProcessor 1 Memo

Page 29

AEjectable: Slimline Diskette or Optical Drive (Optional)BEjectable: Slimline DVD/CD-RW (Standard)1-8SFF SAS Internal Drive cage Drive SupportDrive

Page 30

External StorageExternal StorageExternal StorageExternal Storage QuantityQuantityQuantityQuantitySupportedSupportedSupportedSupportedPositionPositionP

Page 31

NOTE:NOTE:NOTE:NOTE: For an up-to-date listing of the latest O/S Support details for each of the Tape Drives listed below, please see the following:ht

Page 32

HP StorageWorks SCSIHP StorageWorks SCSIHP StorageWorks SCSIHP StorageWorks SCSIRack-Mount Tape DriveRack-Mount Tape DriveRack-Mount Tape DriveRack-Mo

Page 33

Part numberPart numberPart numberPart number348114-001Operational Input Voltage RangeOperational Input Voltage RangeOperational Input Voltage RangeOpe

Page 34

Expansion SlotsExpansion SlotsExpansion SlotsExpansion SlotsBus speedBus speedBus speedBus speedBus numberBus numberBus numberBus numberPCI VoltagePCI

Page 35

Optional Country Power Cords and Jumper CordsOptional Country Power Cords and Jumper CordsOptional Country Power Cords and Jumper CordsOptional Countr

Page 36

System Unit RackSystem Unit RackSystem Unit RackSystem Unit RackChassis FootprintChassis FootprintChassis FootprintChassis Footprint(HxWxD)6.94 x 19 x

Page 37

24X Max (or higher) IDE24X Max (or higher) IDE24X Max (or higher) IDE24X Max (or higher) IDECD-ROM Drive Slim LineCD-ROM Drive Slim LineCD-ROM Drive S

Page 38

CD-Extra CD-RW CD-R CD Text PhotoCD CD-I (mode 2) CD-I Ready CD-Bridge CapacityDVD-ROMDVD-SL4.7 GB/side

Page 39

Integrated Lights-Out 2Integrated Lights-Out 2Integrated Lights-Out 2Integrated Lights-Out 2StandardStandardStandardStandard (integrated onsystem boar

Page 40

Smart Array P400Smart Array P400Smart Array P400Smart Array P400ControllerControllerControllerControllerDisk Drive and EnclosureDisk Drive and Enclosu

Page 41

© Copyright 2006 Hewlett-Packard Development Company, L.P.The information contained herein is subject to change without notice.Microsoft and Windows a

Page 42

InterfacesInterfacesInterfacesInterfacesSerial1Pointing Device (Mouse)1Video1 front, 1 rearKeyboard1USB 2.0 Ports2 front, 2 rear, 1 internaliLO 2 Remo

Page 43

Insight ManagementAgentsInsight Management Agents should be installed on all HP servers to presentsystem instrumentation, health and configuration inf

Page 44

operating system configurations that can be exploited by viruses,worms, and other blended threats.Virtual Machine Management Pack – provides central m

Page 45

Remote ManagementRemote ManagementRemote ManagementRemote ManagementIntegrated Lights-Out 2 (iLO 2) Standard ManagementVirtual Text Remote ConsoleVirt

Page 46

ServiceabilityServiceabilityServiceabilityServiceabilityInnovative Diagnostic LightingSystem Insight Display - precisely depicts all major subsystems

Comments to this Manuals

No comments