Page view 34
Chapter 2 35
Front and Rear Panel Features
Rear-Panel Features
6 GPIB and parallel interface (Option A4H) is an optional interface. GPIB
supports remote analyzer operation. A parallel port is included for printing
only.
7 RS-232 and parallel interface (Option 1AX) is an optional interface. RS-232
supports remote analyzer operation. A parallel port is included for printing
only.
NOTE Printing is only supported from the parallel port.
8 IF, Video, and Sweep Ports (Option A4J or Option AYX): (Refer to the
specifications guide for more information.)
SWP OUT provides a voltage ramp corresponding to the sweep of the
analyzer (0 V to 10 V).
HI SWP IN (TTL) can be grounded to stop and reset the sweep. Once the sweep
has been stopped, removing the ground will trigger the start of a new sweep.
HI SWP OUT (TTL) is high when the analyzer is sweeping.
AUX VIDEO OUT provides detected video output (before the analog-to-digital
conversion) proportional to vertical deflection of the trace. Output is from 0
V to 1 V. Amplitude-correction factors are not applied to this signal.
AUX IF OUT is a 50 , 21.4 MHz IF output that is the down-converted signal
of the RF input of the analyzer. Amplitude-correction factors are not applied
to this signal. This output is taken after the resolution bandwidth filters and
step gains and before the log amplifier.
NOTE Only one IF and Sweep Port option (Option A4J or Option AYX) can be installed at
a time.
9 FM Demod (Option BAA) demodulates, displays, and measures deviation on
FM signals. You can listen to audio signals on a built-in speaker or with an
earphone. Refer to Det/Demod and FM Demodulation (Option BAA) in the
Options chapter for more information.
Bluetooth FM Demodulation (Option 106) demodulates, displays and measures
deviation on Bluetooth signals. Refer to Det/Demod and Bluetooth FM
Demodulation (Option 106) in the Options chapter for more information.
10 Frequency Extension Assembly controls the microwave front-end
components in the Agilent E4404B, E4405B, E4407B, and E4408B.
c. Only one IF and Sweep Port option (Option A4J or Option AYX) can be
installed at a time.
d. Only one demod option (Option BAA or Option 106) can be installed at a
time.
e. The Frequency Extension Assembly comes standard with the Agilent
E4404B, E4405B and E4407B.
f. Bluetooth
is a trademark owned by its proprietor and used by Agilent
Technologies under license.
g. Option 106 is required to make measurements in Bluetooth Measurement
Personality (Option 228)