8-28 Troubleshooting
C4705-90000
!%"! # $# $#$ # $ &") $ %$ $) $ ## "##$ "# ) ## $
$" # $#$ "#$ "# $ $" ## & $ $ !" "# $ "$
!%# '" "$
" " $ $" $" $#$ # '#
$ "& #$# #%% #" $ * " $" !"##
SERVICE TESTS
8 Thermal control
! $$" ' %$ $) $#$ $ "$"
*$ #$ ## # #!) $ " $+! # $ %$$ #
$ #$ $ "$" $$ # $ $#$
"## $ %$$
*#$ (((( ## # #!) $ " $+! ' $ ! $$" $#$#
$ "$"
xxxx represents the color of the cartridge that is being tested.
$ ! $$" # # $#$ $ "$" $ *" $ "##
$" ## # #!) $ " $+!
If the value (#.##) of the thermal voltage is between 0.5 - 2.25 V then press Enter.
If the value of the thermal voltage is not between 0.5 - 2.25 V then the cartridge has failed the
test. To resolve the problem, try one of the following:
1 Clean the interconnect pad in the carriage or the cartridge that failed the test.
2 Replace the cartridge that failed the test.
3 Perform the pen continuity test page 8Ć30.
4 Replace the carriage page 6Ć34.
*"$ ## # #!) $ " $+! ' $ ! $$" #
"$ $ "$ !%# '" $ "$"
$ ! $$" # # "$ $ * "# "## $"
## # #!) $ " $+!
If the value (#.##) of the BPW threshold is between 100 - 450 then press Enter.
If the value (#.##) of the BPW threshold is not between 100 - 450 then, to resolve the problem, try
one of the troubleshooting tips given in step 5.