alternative cooling solutions may need to be explored by the customer. HP has teamed with Liebert to develop an
innovative data room cooling solution called DataCool. DataCool is a patented overhead climate system utilizing
fluid based cooling coils and localized blowers capable of cooling heat loads of several hundred watts per square
foot. Some of DataCool's highlights are listed below:
Liebert has filed for several patents on DataCool
DataCool, based on Liebert's TeleCool, is an innovative approach to data room cooling
Liquid cooling heat exchangers provide distributed cooling at the point of use
Delivers even cooling throughout the data center preventing hot spots
Capable of high heat removal rates (500 W per square foot)
Floor space occupied by traditional cooling systems becomes available for revenue generating equipment.
Enables cooling upgrades when installed in data rooms equipped with raised floor cooling
DataCool is a custom engineered overhead solution for both new data center construction and for data room upgrades for
high heat loads. It is based on Liebert's TeleCool product, which has been installed in 600 telecommunications equipment
rooms throughout the world. The system utilizes heat exchanger pump units to distribute fluid in a closed system through
patented cooling coils throughout the data center. The overhead cooling coils are highly efficient heat exchangers with
blowers that direct the cooling where it is needed. The blowers are adjustable to allow flexibility for changing equipment
placement or room configurations. Equipment is protected from possible leaks in the cooling coils by the patented
monitoring system and purge function that detects any leak and safely purges all fluid from the affected coils. DataCool has
interleaved cooling coils to enable the system to withstand a single point of failure and maintain cooling capability.
Features and Benefits
Features and BenefitsFeatures and Benefits
Features and Benefits
Fully distributed cooling with localized distribution
Even cooling over long distances
High heat load cooling capacity (up to 500 W per square foot)
Meets demand for narrow operating temperature for computing systems
Allows computer equipment upgrade for existing floor cooled data rooms
Floor space savings from removal of centralized air distribution
Withstand single point of failures
For More Information
For More InformationFor More Information
For More Information
http://www.liebert.com/assets/products/english/products/env/datacool/60hz/
bro_8pg/acrobat/sl_16700.pdf
HP has entered into an agreement with Liebert to reference sell the DataCool solution.
The HP/Liebert business relationship is managed by the HP Complementary Products Division.
DataCool will be reference by HP. Liebert will perform installation, service and support.
HP will compensate the HP Sales Representative and District Manager for each DataCool that Liebert sells to a
customer referred by HP.
An HP/Liebert DataCool website will be setup to get more information on the product and to manage the reference
sales process. Please go to
http://hpcp.grenoble.hp.com/
for more information.
Environmental
EnvironmentalEnvironmental
Environmental
68 to 86 degrees F (20 to 30 degrees C) inlet ambient temperature
0 to 10,000 feet (0 to 3048 meters)
2600 CFM with N+1 blowers. 2250 CFM with N.
65 dBA noise level
Uninterruptible Power Supplies (UPS)
Uninterruptible Power Supplies (UPS)Uninterruptible Power Supplies (UPS)
Uninterruptible Power Supplies (UPS)
HP will be reselling high-end (10-kW and above) three-phase UPS systems from our partners. We will test and qualify a
three-phase UPS for Superdome. The UPS is planned to be available Q1 FY01.
All third-party UPS resold by HP will be tested and qualified by HP to ensure interoperability with our systems
We plan to include ups_mond ups communications capability in the third party UPS(s), thus ensuring consistent
communications strategy with our PowerTrust UPS(s)
We will also establish a support strategy with our third-party UPS partners to ensure the appropriate level of support
our customer have come to expect from HP.
QuickSpecs
HP Integrity Superdome Servers: 16-way, 32-way,
HP Integrity Superdome Servers: 16-way, 32-way,HP Integrity Superdome Servers: 16-way, 32-way,
HP Integrity Superdome Servers: 16-way, 32-way,
and 64-way
and 64-wayand 64-way
and 64-way
Configuration
DA - 11717 Worldwide — Version 1 — June 30, 2003
Page 18
Page view 17
1 2 ... 13 14 15 16 17 18 19 20 21 22 23 ... 38 39

Comments to this Manuals

No comments