Hardware options installation 62
o
The connector labeled "6LFF"of the mini-SAS Y-cable to the primary hard drive cage.
10. Slide the optional hard drive cage fully into the bay until it clicks, and then install the screws.
CAUTION: Always populate each media bay with either a device or a blank. Proper airflow can
only be maintained when the bays are populated. Unpopulated drive bays can lead to improper
cooling and thermal damage.
11. Connect the common end of the mini-SAS Y-cable to the SAS connector B on the system board.
12. Install any hard drives or blanks ("SAS or SATA hard drive option" on page 52).
13. Install the access panel (on page 27).
14. Do one of the following:
o Close or install the tower bezel, as needed.
o Slide the server back into the rack.
15. Power up the server (on page 24).