If NPIV is not supported or not enabled and if the FC switch port cannot be configured to support
loop mode, configure MPX200 ports in point-to-point only mode. In point-to-point only configuration
of MPX200 FC ports, you can perform only offline migration. NPIV and enabling NPIV support
are not options.
Table 9 (page 43) lists the behavior of MPX200 FC ports as determined by the configuration of
various FC switch ports, where:
The Connect and Connect (loop mode) settings are appropriate for online data migration.
The Connect (offline migration only) setting is appropriate for offline data migration.
The No connect setting indicates that the link does not come up unless you change the MPX200
FC port or switch port setting.
Table 9 FC port settings
FC switch port setting
NPIV not supported or NPIV disabledNPIV supported and NPIV enabledMPX200 FC
port setting
FL_Port
nl
(loop only)
F_Port
nl
(P2P only)
F_Port and
FL_Port
nl
(P2P or loop)
FL_Port
nl
(loop only)
F_Port
nl
(P2P only)
F_Port
1
nl
and FL_Port
2
(P2P
3
or loop)
No connectConnect
(offline
migration only)
Connect
(offline
migration only)
No connectConnectConnectP2P only
Connect
nl
(loop mode)
No connectConnect
nl
(loop mode)
Connect
nl
(loop mode)
ConnectConnectAuto (default)
Connect (loop
mode)
No connectConnect (loop
mode)
Connect (loop
mode)
No connectConnect (loop
mode)
Loop only
1
Fabric port
2
Fabric loop port
3
Point-to-point
Presenting LUNs to the MPX200
Data migration requires that LUNs from both the source and destination storage arrays be presented
to the MPX200 from either FC arrays or iSCSI arrays.
When presenting LUNs to the MPX200 FC ports, you must not present LUNs from different arrays
using the same World Wide Unique LUN Name. The MPX200 uses the WWULN of a presented
LUN to determine the number of paths available to a specific array entry. Adding LUNs from
different arrays using the same WWULN as an existing presented LUN to the MPX200 prevents
the MPX200 from creating a new array entry.
The following example shows typical MPX200 LUN information:
LUN Information
_______________
WWULN 60:05:08:b4:00:0b:15:a2:00:00:b0:00:00:12:00:00
Serial Number P5512G39SWN0NE
LUN Number 3
VendorId HP
ProductId HSV300
ProdRevLevel 0005
Portal 0
Lun Size 102400 MB
Lun State Online