Hot Plug SAS/SATA and Non-Hot Plug SATA Models
Front View:
Rear View:
1.
Access panel
1.
Power Supply Cable Socket
2.
System fans
2.
Video Port
3.
Two USB ports
3.
Serial Port
4.
Power on/off & system LEDs
4.
Rear USB ports (2)
5.
Optional 3
rd
and 4
th
3.5" Non-Hot plug SATA or hot plug
SAS/SATA hard drive bays
5.
One GbE LAN ports for NIC 2 (RJ-45)
6.
Optional DVD-RW or DVD-ROM drive
6.
Optional LO100i 10/100 Mbps LAN port for IPMI
management (RJ-45)
7.
Standard 1st and 2nd 3.5" Non-Hot plug SATA or hot plug
SAS/SATA hard drive bays (Small Form Factor drive cage
not shown here. See the Storage Section for orientation of
eight small form factor drive option)
7.
Low-Profile slot cover (not used in this model)
8.
Full-height PCI-Express x16
9.
UID - Rear Unit Identification LED
10.
One GbE LAN ports for NIC 1 (RJ-45)
8.
Eighteen DIMM slots : DDR3 Registered (RDIMM) or
Unbuffered (UDIMM) memory
9.
Expansion Slots:
Non-Hot Plug Models - One full-length/full height x16 PCI-
Express Gen2 slot
Hot Plug Models - One available half-length/full height x16
PCI-Express Gen2 slot and one internal only PCI-Express
Gen2 slot (for internal storage controller - HP Smart Array
P410 Controller ONLY)
10.
Quad-Core Intel® Xeon® 5500 series processors (supports
up to two)
11.
Power supply (500 Watts - standard, other PS options
available)
What's New
Support for SAS and SATA Hot Plug Midline and Enterprise Hard Drives
Support for 400W Hot Plug Redundant Power Supply Option Kit (some configuration restrictions apply)
At A Glance
QuickSpecs
HP ProLiant DL160 Generation 6
Overview
DA - 13247 Worldwide QuickSpecs — Version 11 — 11.16.2009
Page 1
Page view 0
1 2 3 4 5 6 ... 49 50

Summary of Contents

Page 1 - QuickSpecs

Hot Plug SAS/SATA and Non-Hot Plug SATA ModelsFront View:Rear View:1.Access panel1.Power Supply Cable Socket2.System fans2.Video Port3.Two USB ports3.

Page 2

Factory Express Portfoliofor Servers and StorageHP Factory Express offers configuration, customization, integration and deployment services for HP ser

Page 3

For a complete listing of service offerings and information visit:http://www.hp.com/services/proliantserviceshttp://h20219.www2.hp.com/services/us/en/

Page 4

NOTE: High Performance Computing (HPC) interconnect technologies are available for the DL160 G6 under the Cluster Platformproduct portfolio. These hig

Page 5

Non-Hot Plug Serial ATA (SATA) ModelsNOTE: Non-Hot Plug models are not upgradeable to Hot Plug. The addition of a Smart Array controller is supported

Page 6

Country Code Keyxx = 00U.S.xx = 20Brazil (ONLY P/N 490442-xx1)xx = 29Japanxx = 37APDxx = 42Euroxx = AAPRCQuickSpecsHP ProLiant DL160 Generation 6Model

Page 7

NOTE: This section lists some of the steps required to configure a Factory Integrated Model. To ensure only valid configurations areordered, HP recomm

Page 8

Step 2: Choose Required Options (only one of the following from each list unless otherwisenoted)ProcessorsQuad-Core ProcessorsIntel® Xeon® Processor X

Page 9

MemoryRegistered DIMMs (RDIMMs)HP 2GB 2Rx8 PC3-10600R-9 Kit500656-B21HP 4GB 2Rx4 PC3-10600R-9 Kit500658-B21HP 4GB 4Rx8 PC3-8500R-7 LP Kit500660-B21HP

Page 10

Storage ControllersNOTE: A minimum of one Smart Array Controller is ONLY required when purchasingHot Plug CTO Chassis Model (P/N 491532-B21) in Step 1

Page 11

Step 3: Choose Additional Options for Factory IntegrationNOTE: For additional "Core Options" and "Additional Options", please refe

Page 12

The HP ProLiant DL160 G6 server is a high performance, low cost, ultra-dense, dual processor capable, 1U rack server for memoryintense High Performanc

Page 13

NOTE: Some options may not be available for factory integration. Please contact an HP sales representative for additionalinformation.Unique OptionsHP

Page 14

MemoryRegistered DIMMs (RDIMMs)HP 2GB 2Rx8 PC3-10600R-9 Kit500656-B21HP 4GB 2Rx4 PC3-10600R-9 Kit500658-B21HP 4GB 4Rx8 PC3-8500R-7 LP Kit500660-B21HP

Page 15

HP 160GB 3G SATA 7.2K 3.5" ETY HDD458945-B21NOTE: Please see QuickSpecs for Technical Specifications and additionalinformation:http://h18000.www1

Page 16

CommunicationsGigabit Ethernet Adapters HP NC112T PCIe Gigabit Server Adapter503746-B21HP NC360T PCI Express Dual Port Gigabit Server Adapter412648-B2

Page 17

Remote ManagementHP LO100i Advanced Pack, No Media 1-Server License including 1 year of 24x7Technical Support and UpdatesNOTE: For additional License

Page 18

Graphic CardsHP NVIDIA FX3700 512 MB PCI-E 16x KitNOTE: Additional graphics and accelerator cards can be used via third party offering.If using the Hi

Page 19

NOTE: This part number can be used to purchase a single license or to order multiplelicenses with a single activation key. Customers will receive a li

Page 20

For an up-to-date listing of the latest operating system and software support details forHP Ultrium tape drives, please visit: http://www.hp.com/go/co

Page 21

StorageWorks OptionsStorageWorks Fibre Channel HBA NOTE: The following is a list of all Fibre Channel Host Bus Adapters for Windows andLinux. For deta

Page 22

Uninterruptible PowerSystemsHP Rack-mountable UPS HP UPS R1500 G2 UPS HP, R1.5k VA UPS, 1U, NAAF419AHP, R1.5kVA UPS, 1U, INTLAF418AHP, R1.5kVA UPS, 1U

Page 23

and deployment capability. Capabilities provided are:AutoRunAssisted Installation Microsoft Windows 2003 Server and Microsoft Windows 2008 ServerOS an

Page 24

Power Distribution UnitsMonitored PDUs HP Monitored Power Distribution Unit: Full Rack Version HP 17.3 kVA S2324 Monitored PDU- dual input, 3Ø, 24A (N

Page 25

HP Rack SeriesHP Rack 10000 G2 Series (Carbon/Graphite Metallic)10642 G2 (42U) Rack Cabinet 1200mm Deep - Shock PalletAF034A10642 G2 (42U) Rack Cabine

Page 26

NOTE: For additional information regarding KVM switches, Serial Console servers,rack mount monitors, keyboards and all related options please see the

Page 27

HP ProLiant DL160 G6 (all models)NOTE: Memory configurations listed do not apply to "Factory Integrated Models".Standard Memory4GB (2x2GB) o

Page 28

3 DIMM Per Channel800 800 800 800notsupportednotsupportednotsupportednotsupportedNOTE: * Supported with ROM update via ROM Based Setup Utility (RBSU).

Page 29

CPU1 CPU2 slot #population orderslot #population order Chnl 11G; empty1G; emptyChnl 12D; empty2D; empty3A; 2GB DIMM3A; empty Chnl 24H; emp

Page 30

CPU1 CPU2 slot #population orderslot #population order Chnl 11G; empty1G; emptyChnl 12D; 16GB DIMM2D; empty3A; 16GB DIMM3A; empty Chnl 24H

Page 31

CPU1 CPU2 slot #population orderslot #population order Chnl 11G; empty1G; emptyChnl 12D; 16GB DIMM2D; 16GB DIMM3A; 16GB DIMM3A; 16GB DIMM

Page 32

Following are memory options available from HP:MemoryRegistered DIMMs (RDIMMs) HP 2GB 2Rx8 PC3-10600R-9 Kit500656-B21HP 4GB 2Rx4 PC3-10600R-9 Kit50065

Page 33

1-4Four Non-hot plug SATA or four 3.5" Hot-plugSAS/SATA hard drive baysAOptional DVD-ROM, or DVD RW1-8Eight Hot-plug SATA/SAS hard drive baysAOpt

Page 34

ProcessorOne of the followingdepending on ModelIntel® Xeon® Processor X5570 (2.93 GHz, 8MB L3 Cache, 95W, DDR3-1333, HT, Turbo 2/2/3/3)NOTE: Available

Page 35

SATA Hot Plug 3.5" Midline (MDL) Drives QuantitySupportedPositionSupportedController1TB 3G SATA 7.2K750GB 3G SATA 7.2K500GB 3G SATA 7.2K250GB 3G

Page 36

QuantitySupportedPositionSupportedController500GB 6G SAS 7.2K DPUp to 81-8HP Smart Array P800/512 BBWC ControllerHP Smart Array P212/Zero Memory Cont

Page 37

External Storage QuantitySupportedPositionSupportedHost Controller or Adapter20 Modular Smart ArrayUp to 2 per SA-6402Up to 4 per SA-6404ExternalHP Sm

Page 38

3U Rack-Mount Kit HP StorageWorks SCSITape Automation, ExternalDAT 72x10 Autoloader1/8 G2 AutoloaderMSL2024MSL4048ExternalHP SC11Xe Host Bus Adapter

Page 39

HP 750W Power SupplyPart Number - AC 750W PSU512327-B21 Option KitInput Voltage Range (Vrms)100 to 240Frequency Range (Nominal) (Hz)50/60Nominal Input

Page 40

HP 460W Power SupplyPart Number - AC 460W PSU532092-B21 Option KitInput Voltage Range (Vrms)100 to 240Frequency Range (Nominal) (Hz)50/60Nominal Input

Page 41

Power ProLiant DL160 G6 Fully Configured115V/60Hz 220V/50HzFully Loaded System Input Wattage (W)448 445Fully Loaded System Input Current (A rms)3.83

Page 42

System UnitDimensions (H x W x D)(with bezel)1.70 x 17.64 x 26.85 in (4.32 x 44.80 x 68.20 cm)Weight(approximate)Maximum(all hard drives, powersupplie

Page 43

System performance may be reduced if operatingwith a fan fault or above 30°C (86°F).Non-operating-30° to 60°C (-22° to 140°F). Maximum rate ofchange i

Page 44

Non-Hot Plug SATA HardDrives160-GB 7.2K458947-B21Capacity160,041 MBHeight1.028 in (2.61 cm)Width4.0 in (10.16 cm)Depth5.787 in (147.0 mm)InterfaceSATA

Page 45

MemoryTypeDDR3 Registered (RDIMM) or Unbuffered (UDIMM)Standard4 GB(2 x 2 GB) UDIMMs6 GB(3 x 2 GB) UDIMMs12 GB(6 x 2 GB) RDIMMsMaximum (RDIMM)192 GB(1

Page 46

Smart Array P410/410iControllerDisk Drive and EnclosureInterface6Gb/s SAS (Serial Attached SCSI)3Gb/s SATA (Serial ATA)SAS Connectors2 internal (Mini-

Page 47

Storage ControllerNon-Hot Plug SATAModelsHP Embedded SATA RAID Controller (integrated into the south-bridge)supporting SW RAID 0,1,10NOTE: Transfer ra

Page 48

Graphics32MB shared supporting all display resolutions up to 1600x1200 16bpp@75HzNOTE: 8MB is dedicated to video memory.Form FactorRack (1U), (1.75 in

Page 49

intended for heterogeneous environments deploying Windows, Linux,VMware ESX and Microsoft Hyper-V systems.Insight Control server deployment includes o

Page 50

Power Supply500 Watts, auto-switching, high efficiency, PFC (Power Factor Correcting)NOTE: Factory upgradeable to high-efficiency (HE) pluggable or Ho