HP 466131-421 Datasheet

Browse online or download Datasheet for Servers HP 466131-421. HP ProLiant 466133-041 server User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 43
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
The HP ProLiant ML150 G6 is an expandable and affordable solution for growing businesses. Redundant power supply and
redundant fan options help to provide more protection on power and thermal to keep your critical business running. Data security,
which is one of the major concerns in the industry, is ensured by the TPM offering that provides data encryption to protect from data
theft. Companies with remote locations can take advantage of the ML150 G6 embedded Lights-Out 100 remote management
feature to decrease server/company downtime, decrease emergency travel needs, and increase overall productivity. Overall, the HP
ProLiant ML150 G6 is easy on your IT budget with significant headroom to grow with your business.
Front View:
Front View:Front View:
Front View:
Rear View:
Rear View:Rear View:
Rear View:
1.
SATA/SAS adapter card
1.
AC input connector
2.
Card bracket retainer
2.
Expansion slots
3.
Rear fan
3.
UID LED
4.
Side access panel
4.
VGA monitor connector
5.
Processor socket and Heatsink
5.
USB 2.0 ports (4)
6.
LED indicators and power button
6.
Keyboard connector
7.
Upfront USB ports
7.
Mouse connector
8.
Hard drive bays (inside)
8.
NIC port
9.
One full height or two half height media bay (s)
9.
Dedicate NIC port
10.
Optical drive media bay
10.
Serial port connector
11.
DIMM socket (total twelve DIMMs supported)
12.
Power Supply
What's New
What's NewWhat's New
What's New
Support for R5000 and R7000 Uninterruptible Power System.
QuickSpecs
HP ProLiant ML150 Generation 6 (G6)
HP ProLiant ML150 Generation 6 (G6)HP ProLiant ML150 Generation 6 (G6)
HP ProLiant ML150 Generation 6 (G6)
Overview
DA - 13249 North America — Version 29 — November 14, 2011
Page 1
Page view 0
1 2 3 4 5 6 ... 42 43

Summary of Contents

Page 1 - QuickSpecs

The HP ProLiant ML150 G6 is an expandable and affordable solution for growing businesses. Redundant power supply andredundant fan options help to pro

Page 2

SAS/SATA Hot Plug ModelsSAS/SATA Hot Plug ModelsSAS/SATA Hot Plug ModelsSAS/SATA Hot Plug ModelsNOTE:NOTE:NOTE:NOTE: For the Standard Features shipped

Page 3

Internal StorageInternal StorageInternal StorageInternal StorageSAS: 8.0TB (4 x 2TB 3.5") MaximumSATA: 8.0TB (4 x 2TB 3.5") MaximumOptical D

Page 4

The ProLiant Smart Buy program offers a collection of promotional server and option products that are configured with SMB in mind,offered at discounte

Page 5

HP S-Buy ML150G6HP S-Buy ML150G6HP S-Buy ML150G6HP S-Buy ML150G6E5520 8GB SBS 2011E5520 8GB SBS 2011E5520 8GB SBS 2011E5520 8GB SBS 2011659586-S01Proc

Page 6

NOTE:NOTE:NOTE:NOTE: This section lists some of the steps required to configure a Factory Integrated Model. To ensure only valid configurations areord

Page 7

NOTE:NOTE:NOTE:NOTE: All DDR3 memory option kits consist of one DIMM per kit. For detailedmemory configuration rules and guidelines, please use the On

Page 8

HP 2TB 3G SATA 7.2K rpm LFF (3.5-inch) Non-hot Plug Midline 1yr Warranty HardDrive507774-B21HP 1TB 3G SATA 7.2K rpm LFF (3.5-inch) Non-hot Plug Midlin

Page 9

NOTE:NOTE:NOTE:NOTE: Smart Array Advanced Pack (SAAP) is a license key to activate RAID 6 and theadvance feature sets provided by the controller.This

Page 10

NOTE:NOTE:NOTE:NOTE: Some options may not be integrated at the factory. To ensure only valid configurations are ordered, HP recommends the useof an HP

Page 11

HP Drive Cage OptionsHP Drive Cage OptionsHP Drive Cage OptionsHP Drive Cage OptionsHP 5U Large Form Factor (LFF) Hot Plug Drive Cage KitNOTE:NOTE:NOT

Page 12

NOTE: NOTE: NOTE: NOTE: For the Standard Features shipped in the "Factory Integrated Models", please see the "Configuration Information

Page 13

HP 450GB 6G SAS 15K rpm LFF (3.5-inch) Non-hot Plug Dual Port Enterprise 3yrWarranty Hard Drive516826-B21HP 300GB 6G SAS 15K rpm LFF (3.5-inch) Non-ho

Page 14

HP Power SuppliesHP Power SuppliesHP Power SuppliesHP Power SuppliesPower SuppliesPower SuppliesPower SuppliesPower SuppliesHP 750W Common Slot Gold H

Page 15

NOTE: NOTE: NOTE: NOTE: Some options may not be integrated at the factory. To ensure only valid configurations are ordered, HP recommends the useof an

Page 16

Optional UpgradesOptional UpgradesOptional UpgradesOptional Upgrades HP 256MB P-series Cache UpgradeNOTE:NOTE:NOTE:NOTE: Supported on HP Smart Array P

Page 17

HP Backup & RecoveryHP Backup & RecoveryHP Backup & RecoveryHP Backup & RecoverySoftwareSoftwareSoftwareSoftwareData Protector Express

Page 18

HP Uninterruptible PowerHP Uninterruptible PowerHP Uninterruptible PowerHP Uninterruptible PowerSystemsSystemsSystemsSystemsHP Tower UPSHP Tower UPSHP

Page 19

HP Rack SeriesHP Rack SeriesHP Rack SeriesHP Rack SeriesHP 10642 G2 Pallet Universal RackAF001AHP 10642 G2 Shock Universal RackAF002ANOTE:NOTE:NOTE:NO

Page 20

NOTE:NOTE:NOTE:NOTE: For additional information regarding KVM switches, Serial Console servers,rack mount monitors, keyboards and all related options

Page 21

HP ProLiant ML150 G6 Memory Population GuidelinesHP ProLiant ML150 G6 Memory Population GuidelinesHP ProLiant ML150 G6 Memory Population GuidelinesHP

Page 22

If you install 1x 1066MHz DIMM in channel 1 and 5x 1333MHz DIMMs with 1 DIMM Per Channel (DPC) in each of the otherchannels, you run at 1066MHzIf you

Page 23

MemoryMemoryMemoryMemoryTypeDDR3 Registered (RDIMM) or Unbuffered (UDIMM)DIMM SlotsTotal 12 DIMM slotsStandard(Entry/Base Models)2 GBStandard(Performa

Page 24

CPU1CPU1CPU1CPU1 CPU2CPU2CPU2CPU2 slot #population orderslot #population order Chnl 11D: 2GB DIMM1D: emptyChnl 12A: 4GB DIMM2A: empty Chnl

Page 25

CPU1CPU1CPU1CPU1 CPU2CPU2CPU2CPU2 slot #population orderslot #population order Chnl 11D: 4GB DIMM1D: 4GB DIMMChnl 12A: 4GB DIMM2A: 4GB DIMM

Page 26

Following are memory options available from HP:Following are memory options available from HP:Following are memory options available from HP:Following

Page 27

Non-Hot Plug SATA or Hot Plug SAS/SATANon-Hot Plug SATA or Hot Plug SAS/SATANon-Hot Plug SATA or Hot Plug SAS/SATANon-Hot Plug SATA or Hot Plug SAS/SA

Page 28

2TB 3G SATA 7.2K1TB 3G SATA 7.2K500GB 3G SATA 7.2KUp to 44(Drive slots 1-4)HP Smart Array B110i SATA RAID Controller (RAID 0,1,10)Smart Array P212 Con

Page 29

NOTE:NOTE:NOTE:NOTE: To support 8 drives, the purchase of the optional 2nd hot plug drive cage, 750W Redundant Power Supply, RedundantPower Supply Ena

Page 30

LTO-5 Ultrium 3280 HP SAS Rack Mount KitsHP SAS Rack Mount KitsHP SAS Rack Mount KitsHP SAS Rack Mount Kits1U Rack-Mount Kit3U Rack-Mount KitExterna

Page 31

HP 460W Factory Integrated Power Supply KitHP 460W Factory Integrated Power Supply KitHP 460W Factory Integrated Power Supply KitHP 460W Factory Integ

Page 32

PowerPowerPowerPower**HP ProLiant ML150 G6 Fully Configured(see**)Fully Loaded System Input Wattage (W)567W (595W)Fully Loaded System Input Current (

Page 33

System UnitSystem UnitSystem UnitSystem UnitDimensionsDimensionsDimensionsDimensions (WxHxD)7.87 x 16.81 x 24.13 in (200 x 427 x 613 mm) (W/O foot sta

Page 34

Internal Storage DevicesInternal Storage DevicesInternal Storage DevicesInternal Storage DevicesOne of the followingdepending on ModelDiskette DriveNo

Page 35

average bystander position A-Weighted sound pressure levels (LpAm) whenthe product is operating in a 23°C ambient environment. Noise emissionswere mea

Page 36

HP Half-Height SATAHP Half-Height SATAHP Half-Height SATAHP Half-Height SATADVD-ROM Optical DriveDVD-ROM Optical DriveDVD-ROM Optical DriveDVD-ROM Opt

Page 37

Embedded HP NC107iEmbedded HP NC107iEmbedded HP NC107iEmbedded HP NC107iPCI Express GigabitPCI Express GigabitPCI Express GigabitPCI Express GigabitSe

Page 38

© Copyright 2011 Hewlett-Packard Development Company, L.P.The information contained herein is subject to change without notice.Microsoft and Windows N

Page 39

Server Power CordServer Power CordServer Power CordServer Power CordOne Lowline NEMA power cordPower SupplyPower SupplyPower SupplyPower SupplyStandar

Page 40

Embedded ManageabilityEmbedded ManageabilityEmbedded ManageabilityEmbedded ManageabilityHP LO100i AdvancedHP LO100i AdvancedHP LO100i AdvancedHP LO100

Page 41

Factory Express PortfolioFactory Express PortfolioFactory Express PortfolioFactory Express Portfoliofor Servers and Storagefor Servers and Storagefor

Page 42

Service and SupportService and SupportService and SupportService and SupportHP Technology Services for Industry Standard Servers and BladeSystemHP Tec

Page 43

Standard Care PackageStandard Care PackageStandard Care PackageStandard Care PackagePackage that maintains high level of server availabilityPackage th

Comments to this Manuals

No comments