HP LC2000r - NetServer - 128 MB RAM Installation Guide Page 171

  • Download
  • Add to my manuals
  • Print
  • Page
    / 194
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 170
Appendix A Specifications
163
Environmental Requirements
The specifications listed below can vary if you install a mass storage device in
your HP NetServer that has more stringent environmental limits. Ensure the
operating environment is suitable for all mass storage devices in use.
Table A-5. Environmental Requirements
BTU
1845 BTU/hr maximum
Temperature
Operating
5° C to 35°C
(41°F to 95° F)
Non-operating
–40° C to +65° C
(–40° F to +149° F)
Humidity
Operating
20% to 80% relative humidity
(non-condensing)
Non-operating
5% to 95% relative humidity
(non-condensing)
Altitude
Operating
-30 to 3,045 m (10,000 ft)
Non-operating
-30 to 12,180 m (40,000 ft)
Acoustic Emissions
Sound Level: (LpA) < 50 dB(A) bystander position