Page view 11
Microtower
MicrotowerMicrotower
Microtower
Slim Tower
Slim TowerSlim Tower
Slim Tower
Power Supply
Power SupplyPower Supply
Power Supply
Power Supply
240-watt ATX power supply – PFC 115v/230v line
switch
150-watt ATX power supply – PFC 115v/230v line
switch
Full Ranging Input (No
Line Select Switch)
No No
Active Power Factor
Correction (APFC) (Input
Current is nearly 1/2 a
non-APFC PS)
No No
Passive Power Factor
Correction (PFC)
Yes (with line switch set to 230V – No PFC in 115V
line switch position)
Yes (with line switch set to 230V – No PFC in 115V
line switch position)
Operating Voltage Range
90 to 132VAC, or 180 to 264VAC 90 to 132VAC, or 180 to 264VAC
Rated Voltage Range
100 to 127VAC, or 200 to 240VAC 100 to 127VAC, or 200 to 240VAC
Rated Line Frequency
50 – 60 Hz 50 – 60 Hz
Operating Line Frequency
Range
47 – 63 Hz 47 – 63 Hz
Rated Input Current
6A @ 100VAC/3A @ 200VAC
5A @ 100VAC/2.5A @ 200VAC
Maximum Rated Power
240 watt
150 watt (system rated for 130W maximum)
Heat Dissipation
Max (369W input): 1260 BTU/hr Typical (75W
input): 256 BTU/hr Max (369W input): 317 kg-
cal/hr Typical (75W input): 65 kg-cal/hr
Max (200W input): 683 BTU/hr Typical (75W
input): 256 BTU/hr Max (200W input): 172 kg-
cal/hr Typical (75W input): 65 kg-cal/hr
PS Fan
92mm fan integrated in power supply – variable
speed for optimum acoustics
PS cooling achieved via ducting of airflow from
processor fan.
Processor Fan
Variable speed fan Variable speed fan
Environmental and
Environmental andEnvironmental and
Environmental and
Mechanical Engineering
Mechanical EngineeringMechanical Engineering
Mechanical Engineering
Support Center
Support CenterSupport Center
Support Center
http://env-webserver.ccm.cpqcorp.net/EMESC/default.htm
Microtower
MicrotowerMicrotower
Microtower
Slim Tower
Slim TowerSlim Tower
Slim Tower
Power Conservation
Power ConservationPower Conservation
Power Conservation
‘Energy Saver'
‘Energy Saver'‘Energy Saver'
‘Energy Saver'
Energy Star Compliant
Yes Yes
APM 1.2 Support
No No
Screen Blanking
Yes Yes
Hard Disk ‘Idle' Mode
Yes Yes
System Idle Mode
Yes Yes
Cache Memory Power-
Down
No No
Blue Angel Compliant
(<5w in S5--Power Off)
Yes Yes
Power Consumption in ES
Mode – Suspend to RAM
(S3) (Instantly Available
PC)
~2W ~2W
QuickSpecs
HP Business Desktop d325 Series
HP Business Desktop d325 SeriesHP Business Desktop d325 Series
HP Business Desktop d325 Series
Standard Features - Base Unit Details
DA - 11642 North America — Version 24 — August 23, 2005
Page 12
Page view 11
1 2 ... 7 8 9 10 11 12 13 14 15 16 17 ... 47 48

Comments to this Manuals

No comments