POWER TRANSFORMER REMOVAL
Reinstallation
1. Rest transformer on the bottom plate with its primary
terminals toward the oven face plate.
2.
Secure transformer with four screws to bottom plate.
3. Re-connect wire leads (primary) to power transformer
and filament leads and high voltage wire of transformer
to magnetron and high voltage capacitor. Refer to
"PICTORIAL DIAGRAM" on page 33.
4. Re-install outer case and check that oven is operating
properly.
1. Disconnect the power supply cord and then remove
outer case.
2. Open the oven door and block it open.
3. Discharge high voltage capacitor.
4. Disconnect wire leads (primary) from power transformer
and the filament leads and high voltage wire from the
magnetron and capacitor terminals.
5. Remove four (4) screws holding transformer to bottom
plate.
6. Remove transformer from bottom plate.
1. Disconnect the power supply cord, and then remove
outer case.
2. Open the door and block it open.
3. Discharge high voltage capacitor.
4. Open covers of the terminal insulator by using small flat
type screw driver.
5. Remove the receptacle from the terminal insulator.
6. Now, the terminal insulator is free.
Installation
1. Insert the receptacle into terminal insulator.
2. Close covers of the terminal insulator, as shown below.
3. Reconnect all leads removed from components during
testing.
4. Reinstall the outer case (cabinet).
5. Reconnect the power supply cord after the outer case is
installed.
6. Run the oven and check all functions.
Terminal
insulator
Flat type
screw driver
RECEPTACLE
COVERS
TERMINAL INSULATOR REPLACEMENT
CAUTION: 1. DISCONNECT OVEN FROM POWER SUP
PLY BEFORE REMOVING OUTER CASE.
2. DISCHARGE THE HIGH VOLTAGE CA-
PACITOR BEFORE TOUCHING ANY OVEN
COMPONENTS OR WIRING.
HIGH VOLTAGE RECTIFIER AND HIGH VOLTAGE CAPACITOR REMOVAL
1. Disconnect the power supply cord and then remove
outer case.
2. Open the door and block it open.
3. Discharge high voltage capacitor.
4. Disconnect the high voltage wire of the power transformer
from the high voltage capacitor.
5. Disconnect the high voltage wire of high voltage rectifier
assembly from the magnetron.
6. Disconnect the filament lead (short one) of the power
transformer from the high voltage capacitor.
7. Remove two (2) screws holding capacitor holder to
oven cavity rear plate.
8. Remove one (1) screw holding high voltage rectifier
assembly to capacitor holder.
9. Disconnect rectifier terminal from capacitor.
High voltage rectifier assembly is now free.
10.Remove capacitor holder. Capacitor is now free.
CAUTION: WHEN REPLACING HIGH VOLTAGE RECTI-
FIER AND HIGH VOLTAGE CAPACITOR,
GROUND SIDE TERMINAL OF THE HIGH
VOLTAGE RECTIFIER MUST BE SECURED
FIRMLY WITH A GROUNDING SCREW.
MAGNETRON REMOVAL
Removal
1. Disconnect the power supply cord and then remove
outer case.
2. Open the door and block it open.
3. Discharge high voltage capacitor.
4. Disconnect all wire leads from magnetron.
5. Remove the five (5) screws holding chassis support to
magnetron, oven cavity back plate, oven cavity front
flange and fan duct.
6. Remove the chassis support from oven.
7. Carefully remove the four (4) screws holding magnetron
to waveguide flange.
8. Lift up magnetron with care so that magnetron antenna
is not hit by any metal object around antenna.
NOTE: When replacing the outer case, the 2 special
Torx screws must be reinstalled in the same
locations.