Hp E1368A User Manual

Browse online or download User Manual for Microwaves Hp E1368A. HP E1368A User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 88
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
Artisan Technology Group is your source for quality
new and certied-used/pre-owned equipment
FAST SHIPPING AND
DELIVERY
TENS OF THOUSANDS OF
IN-STOCK ITEMS
EQUIPMENT DEMOS
HUNDREDS OF
MANUFACTURERS
SUPPORTED
LEASING/MONTHLY
RENTALS
ITAR CERTIFIED
SECURE ASSET SOLUTIONS
SERVICE CENTER REPAIRS
Experienced engineers and technicians on staff
at our full-service, in-house repair center
WE BUY USED EQUIPMENT
Sell your excess, underutilized, and idle used equipment
We also offer credit for buy-backs and trade-ins
www.artisantg.com/WeBuyEquipment
REMOTE INSPECTION
Remotely inspect equipment before purchasing with
our interactive website at www.instraview.com
LOOKING FOR MORE INFORMATION?
Visit us on the web at www.artisantg.com for more
information on price quotations, drivers, technical
specications, manuals, and documentation
Contact us: (888) 88-SOURCE | sales@artisantg.com | www.artisantg.com
SM
View
Instra
Page view 0
1 2 3 4 5 6 ... 87 88

Summary of Contents

Page 1 -

Artisan Technology Group is your source for quality new and certied-used/pre-owned equipment• FAST SHIPPING AND DELIVERY• TENS OF THOUSANDS OF IN-S

Page 2 - Contents

Reader Comment SheetHP E1368A, E1369A, E1370A Microwave Switch and Driver Modules User’s ManualEdition 3You can help us improve our manuals by sharin

Page 3

10 HP E1368A, E1369A, E1370A Microwave Switch and Driver Modules User’s ManualArtisan Technology Group - Quality Instrumentation ... Guaranteed |

Page 4

Chapter 1Getting Started with the HP E1368A/69A/70AUsing This ChapterThis chapter describes the Microwave Switch modules, and containsinformation on

Page 5

Figure 1-1. HP Microwave Switch Block Diagram12 Getting Started with the HP E1368A/69A/70A Chapter 1Artisan Technology Group - Quality Instrumentati

Page 6

Power SupplyCircuitPower to operate the coaxial switches can be supplied internally orexternally, dependent on the type of coaxial switch used.• Inter

Page 7 - Safety Symbols

Instrument DefinitionHP plug-in modules installed in an HP mainframe or used with an HPcommand module are treated as independent instruments each havi

Page 8

The logical addresses noted in Figure 1-2 apply to modules installed in anHP 75000 Series B Mainframe (HP Model Number E1300/E1301) or in amainframe w

Page 9

SCPI CommandFormat Used inThis ManualYou can send SCPI commands in either short or long form. Refer toChapter 4 for more information. A long form ex

Page 10 - BUSINESS REPLY MAIL

Chapter 2Configuring the HP E1368A/69A/70AModulesUsing This ChapterThis chapter shows how to connect external wiring to the MicrowaveSwitch Modules c

Page 11

Setting the Address SwitchThe logical address switch (LADDR) factory setting is 120. You may havechanged the setting during module installation. Val

Page 12 - Microwave Switch Description

ContentsHP E1368A/69A/70A Modules User’s ManualWarranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Page 13

Selecting the Interrupt PriorityThe Microwave Switch modules generate interrupts after a channel has beenclosed or opened. These interrupts are sent

Page 14 - Switches

Installing Switches on the HP E1369ABecause the HP E1369A Microwave Switch modules do not haveMicrowave Switches installed by the factory, it is neces

Page 15 - Instrument Definition

After selecting the coaxial switch, install as follows:1. Position the coaxial switch behind the channel 00 panel cut-out.Secure to rear panel using

Page 16 - CLOSe (@102)

Figure 2-3. Microwave Switch Installation22 Configuring the HP E1368A/69A/70A Modules Chapter 2Artisan Technology Group - Quality Instrumentation

Page 17 - Initial Operation

ConnectingSwitches Externalto the ModuleConnection of up to five coaxial switches (channels 00-04) is describedbelow. Figure 2-4 shows the wiring dia

Page 18 - Warnings and Cautions

Selecting SwitchPowerAfter the coaxial switches have been installed (refer to “Installing Switcheson the HP E1369A” earlier in this chapter), the corr

Page 19 - Setting the Address Switch

Connecting FieldWiringFigure 2-6 shows the internal switch diagram for the various HP 3-port,4-port, and 5-port coaxial switches. All switches are sh

Page 20

Installing a Switch or Attenuator on the HP E1370AMicrowave Switch/Attenuator CardBecause the HP E1370A Microwave Switch/Attenuator modules do nothave

Page 21 - Installing Switches

After selecting the coaxial switch or attenuator, install as follows:1. Position the coaxial switch or attenuator behind the panel cut-out.Use two M3

Page 22

Connecting FieldWiringFigure 2-8 shows the internal switch diagram for the various HPsingle-pole, multi-throw switches. All switches are shown in the

Page 23

Example: Transfer Switch Using Two 3-Port Switches . . . . . . . . . . . . . . . 36Example: Transfer Switch Using One 5-Port Switch .

Page 24 - Switches External

Chapter 3Using the HP E1368A/69A/70A ModulesUsing This ChapterThis chapter uses typical examples to show how to use the MicrowaveSwitch modules. Thi

Page 25 - Selecting Switch

Reset ConditionsWhen the Microwave Switch is switched on or *RST (reset), all channelsare set to open (refer to Figure 2-6), and the current channel l

Page 26 - Connecting Field

Switching ChannelsFor general purpose switch operation, you can connect or disconnect asignal by opening or closing a specific channel.• Use CLOS <

Page 27 - Installing a Switch

Example: SingleChannel Switchingusing EXTernalPOWERThis example illustrates closing and opening coaxial switch channel 01 in aHP E1369A Microwave Swit

Page 28

Example: ChannelSwitching using theE1370A and the33366K MicrowaveSwitchThis example illustrates how to make connections to different ports on theHP E1

Page 29

Note: Because of the specific ribbon cable configurations, the channel numberdoes not directly correspond to the same port number. Table 3-3 maps the

Page 30 - Microwave Switch Commands

Example: MultipleChannel Switchingusing EXTernalPOWERThis example illustrates closing and opening coaxial switch channels 00through 04 in a HP E1369A

Page 31 - Reset Conditions

Example: TransferSwitch Using Two3-Port SwitchesThis example shows how to configure the HP E1368A Microwave Switchto either route a signal directly to

Page 32 - Switching Channels

Example: TransferSwitch Using One5-Port SwitchThis example shows how to configure the HP E1369A Microwave SwitchDriver with a 5-port switch (HP 33313

Page 33 - Channel Switching

Example: 4 x 1MultiplexerThis example shows how to configure the HP E1368A Microwave Switchto select one of four signals for output. For the example,

Page 34 - 33366K Microwave

SYSTem . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65:CDEScription?

Page 35

Scanning ChannelsScanning the Microwave Switch module channels consists of closing a setof channels (connecting the 2 port to the C port) one channel

Page 36 - Example: Multiple

Example: ScanningChannelsThis example uses the mainframe’s "Trig Out" port to synchronizeMicrowave Switch channel 00 to 02 closures to an ex

Page 37 - 3-Port Switches

Example: Using theScan Complete BitYou can use the Scan Complete Bit (bit 8) in the Operation Status Registerof a switchbox to determine when a scanni

Page 38 - 5-Port Switch

Execute:10 OUTPUT 70915;"*CLS" !Clear all switchbox statusstructure.20 OUTPUT 70915;"STAT:OPER:ENAB 256"!Enable Scan Complete Bit

Page 39 - Multiplexer

Recalling and Saving StatesThis section contains information about saving and recalling switch states.Storing States The *SAV <numeric_state> co

Page 40 - Scanning Channels

For the example, use:• an HP-IB select code of 7, primary address of 09, and secondaryaddress of 15 for the Microwave Switch • an HP Series 200/300 Co

Page 41 - Channels

350 OUTPUT 70915;"*CLS"360 STOP370 SUBENDComments If you have an HP 75000 Series B mainframe with a front panel keyboard,errors can be monit

Page 42 - Scan Complete Bit

Querying the Microwave SwitchThis section summarizes the query commands you can use to determine theconfiguration or state of the Microwave Switch. A

Page 43

Chapter 4HP E1368A/69A/70A Command ReferenceUsing This ChapterThis chapter describes Standard Commands for Programmable Instruments(SCPI) commands an

Page 44 - Detecting Error Conditions

Command Separator A colon (:) always separates one command from the next lower levelcommand as shown below:ROUTe:SCAN:MODE?Colons separate the root co

Page 45 - Execute:

Notes4 HP E1368A/69A/70A Modules User’s Manual ContentsArtisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.arti

Page 46 - Instruments

Parameters Parameter Types. The following table contains explanations and examplesof parameter types you might see later in this chapter.Parameter Ty

Page 47 - Querying the Microwave Switch

SCPI Command ReferenceThis section describes the Standard Commands for ProgrammableInstruments (SCPI) commands for the Microwave Switch modules.Comman

Page 48 - Command Types

ARMThe ARM subsystem selects the number of scanning cycles (1 through32767) for each INITiate command.ARM:COUNt <number> MIN | MAX:COUNt? [MIN |

Page 49

:COUNt? ARM:COUNt? [MIN | MAX] returns the current number of scanning cyclesset by ARM:COUNt. The current number of scans cycles is returned whenno

Page 50

DISPlayThe DISPlay subsystem monitors the channel state of a selected module (orcard) in a switchbox. This subsystem only operates with mainframes th

Page 51 - SCPI Command Reference

:MONitor[:STATe] DISPlay:MONitor[:STATe] <mode> turns the monitor mode ON or OFF.ParametersParameter Name Parameter Type Range of Values Defaul

Page 52

INITiateThe INITiate subsystem selects continuous scanning cycles and starts thescanning cycle.Subsystem Syntax INITiate:CONTinuous <mode>:CONTi

Page 53 - Parameters

:CONTinuous? INITiate:CONTinuous? queries the scanning state. With continuousscanning enabled, the command returns 1. With continuous scanningdisab

Page 54

OUTPutThe OUTPut subsystem enables or disables the "Trig Out" port of the HPE1300/E1301 Mainframe or on the HP Command Module. Subsystem Syn

Page 55

[ROUTe:]The ROUTe subsystem controls switching and scanning operations for theMicrowave Switch modules in a switchbox. Subsystem Syntax [ROUTe:]CLOSe

Page 56 - INITiate

CertificationHewlett-Packard Company certifies that this product met its published specifications at the time of shipment from the factory. Hewlett-P

Page 57 - [:IMMediate]

CLOSe? [ROUTe:]CLOSe? <channel_list> returns the current state of thechannel(s) queried. The channel_list is in the form (@ccnn). Thecommand

Page 58

OPEN? [ROUTe:]OPEN? <channel_list> returns the current state of the channel(s)queried. The channel_list is in the form (@ccnn). The command r

Page 59 - [ROUTe:]

SCAN:MODE [ROUTe:]SCAN:MODE <mode> is accepted by the Microwave Switch.NONE, VOLT, and RES set the mode for "no measurements" while

Page 60

STATusThe STATus subsystem reports the bit values of the Operation StatusRegister. Only bit 8 in the Standard Operation Status Register is used tonot

Page 61

:OPERation:ENABle STATus:OPERation:ENABle <number> enables the Standard OperationStatus Register to set a bit in the Status Byte Register. For

Page 62

:OPERation[:EVENt]? STATus:OPERation[:EVENt]? queries the status of the StandardOperation Status Event Register.Comments • Output Format: Returns a d

Page 63 - Subsystem Syntax STATus

SYSTemThe SYSTem subsystem returns error numbers/messages in the error queueof a switchbox, and returns the types and descriptions of modules (cards)

Page 64

:CTYPe? SYSTem:CTYPe? <number> returns the module (card) type of a selectedmodule in a switchbox.ParametersParameter Name Parameter Type Range

Page 65

TRIGgerThe TRIGger subsystem controls the triggering operation of the MicrowaveSwitch modules in a switchbox.Subsystem Syntax TRIGger[:IMMediate]:SOUR

Page 66

Comments • Enabling the Trigger Source: The TRIGger:SOURce commandonly selects the trigger source. The INITiate[:IMMediate] commandenables the trigge

Page 67

Frame or chassis ground terminal—typi-cally connects to the equipment’s metalframe.Alternating current (AC).Direct current (DC). Indicates hazardous v

Page 68 - HOLD discrete Hold triggering

Scanning Using Bus TriggersThis example uses bus triggering (TRIG:SOUR BUS) to scan channels 00through 02 of a single-module switchbox. The trigger s

Page 69

IEEE 488.2 Common CommandsThe following table lists the IEEE 488.2 Common (*) Commands that canbe executed by the Microwave Switch modules. The opera

Page 70

Command Quick ReferenceThe following tables summarize SCPI and IEEE 488.2 Common (*)Commands for the Microwave Switch modules.SCPI Commands for Quick

Page 71 - IEEE 488.2 Common Commands

72 HP E1368A/69A/70A Command Reference Chapter 4Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.

Page 72 - Command Quick Reference

Appendix AHP E1368A/69A/70A SpecificationsHP E1368A Microwave SwitchFrequency Range:DC-18 GHzCharacteristic Impedence:50ΩInsertion Loss:DC-2GHz: <

Page 73

74 HP E1368A/69A/70A Specifications Appendix AArtisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

Page 74 - Appendix A

Appendix BHP E1368A/69A/70A RegistersRegister DefinitionsAll three Microwave Switch modules are register-based devices. See thetables below for regi

Page 75

Addressing the RegistersTo read or write to specific registers, you must use the register address.Register addresses for HP 75000 Series C plug-in mod

Page 76 - HP E1368A/69A/70A Registers

Status/ControlRegisterEach coaxial switch requires about 30 msec execution time (close to open oropen to close) during which time the switch is "

Page 77 - Reading the Registers

78 HP E1368A/69A/70A Registers Appendix BArtisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

Page 78 - Writing to the Registers

Declaration of Conformityaccording to ISO/IEC Guide 22 and EN 45014Manufacturer’s Name: Hewlett-Packard CompanyLoveland Manufacturing CenterManufactur

Page 79

Appendix CHP E1368A/69A/70A Error MessagesTable C-1 lists the error messages associated with the Microwave Switchmodule programmed by SCPI. See the

Page 80 - Appendix C

Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

Page 81

IndexHP E1368A/69A/70A Modules User’s Manual*CLS, 29, 70*ESE, 29, 70*ESE?, 70*ESR?, 70*IDN, 70*OPC, 70*OPC?, 70*RCL, 43, 70*RST, 29 - 30, 70 - 71*SAV

Page 82

parameters, 49query, 46Quick Reference, 71SCPI, 47SCPI format, 16, 47separator, 48types, 47Comment sheet, reader, 9Common (*) Commands, 47*CLS, 29, 70

Page 83

*ESR?, 70Event In Port, 68Exampleschannel switching with E1369A, 35channel switching with E1370A, 33checking for errors, 43 - 44multiple channel switc

Page 84

NNon-HP Switches, 20Numeric Command Parameters, 49O*OPC, 70*OPC?, 70OPEN, ([ROUTe:]OPEN), 14, 29, 59, 71OPEN?, ([ROUTe:]OPEN?), 46, 60, 71Openingchann

Page 85

SSafety warnings, 6, 17*SAV, 43, 70Saving Switch States, 43Scan Complete Bit, 41SCAN, ([ROUTe:]SCAN), 29, 60, 71SCAN:MODE, ([ROUTe:]SCAN:MODE), 30, 61

Page 86

transfer, 36 - 37Switchingchannels, 31, 33, 35channels with E1369A, 35channels with E1370A, 33multiple channels, 33, 35single channels, 31 - 32Synchro

Page 87

Artisan Technology Group is your source for quality new and certied-used/pre-owned equipment• FAST SHIPPING AND DELIVERY• TENS OF THOUSANDS OF IN-S

Page 88

Notes8 HP E1368A, E1369A, E1370A Microwave Switch and Driver Modules User’s ManualArtisan Technology Group - Quality Instrumentation ... Guaranteed